Optical coherence tomography study of healing characteristics of paclitaxel-eluting balloons vs. everolimus-eluting stents for in-stent restenosis: the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) randomised clinical trial

被引:62
|
作者
Adriaenssens, Tom [1 ,2 ]
Dens, Jo [3 ]
Ughi, Giovanni [1 ,2 ]
Bennett, Johan [1 ,2 ]
Dubois, Christophe [1 ,2 ]
Sinnaeve, Peter [1 ,2 ]
Wiyono, Stefanus [1 ,2 ]
Coosemans, Mark [1 ,2 ]
Belmans, Ann [1 ,2 ]
D'hooge, Jan [1 ,2 ]
Vrolix, Mathias [3 ]
Desmet, Walter [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Dis, Univ Hosp Leuven, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[3] ZOL Hosp Genk, Genk, Belgium
关键词
drug-eluting balloon; drug-eluting stent; in-stent restenosis; optical coherence tomography; percutaneous coronary intervention; stent coverage; BARE-METAL STENTS; COATED BALLOON; FOLLOW-UP; VASCULAR BRACHYTHERAPY; MYOCARDIAL-INFARCTION; NEOINTIMAL COVERAGE; ANGIOPLASTY; NEOATHEROSCLEROSIS; ANGIOGRAPHY; PREVENTION;
D O I
10.4244/EIJV10I4A77
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Little is known about the respective healing responses and clinical efficacy and safety of drug-eluting balloons (DEB) and the second generation of drug-eluting stents (DES) when used to treat in-stent restenosis (ISR). In this study, we set out to compare prospectively the healing characteristics, as assessed by optical coherence tomography (OCT), of DEB versus DES after treatment of ISR in bare metal stents (BMS). Methods and results: Fifty patients with BMS ISR were randomised to treatment with a paclitaxel-eluting balloon vs. an everolimus-eluting stent (EES). The primary endpoint was the percentage of uncovered struts, assessed with OCT at nine months, as a marker of vessel wall healing. A mean of 366 +/- 135 and 636 +/- 184 struts were analysed per patient in the DEB and EES groups, respectively. The percentage of uncovered struts per patient was significantly lower with DEB vs. EES (1.4% vs. 3.1%, p=0.025). Mean neointimal hyperplasia area was 2.4 +/- 1.08 mm(2) in DEB vs. 1.92 +/- 0.67 mm(2) in EES (p=0.1806), while the percentage of malapposed struts per patient was very low in both groups (0.2% vs. 0.3%, p=0.699). At nine months, angiographic in-stent MLD (minimum lumen diameter) was lower (2.13 vs. 2.54 mm, p=0.006), while diameter stenosis (26.4 vs. 11.4%, p=0.002), and LLL (0.28 vs. 0.07 mm, p=0.1) were higher after DEB compared to EES. During one-year follow-up, we did not observe differences in the rates of death, TLR (target lesion revascularisation) or stent thrombosis. Conclusions: DEB appears to be associated with better healing characteristics, as assessed by stent strut coverage with OCT, but tended to be slightly less effective compared to EES. These findings give support to the use of either DEB or EES as valuable treatment options for ISR.
引用
收藏
页码:439 / 448
页数:10
相关论文
共 50 条
  • [31] Comparison of in-stent neoatherosclerosis and tissue characteristics between early and late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study
    Sabbah, Mahmoud
    Kadota, Kazushige
    El-Eraky, Azza
    Kamal, Hanan M.
    Abdellah, Ahmed-Tageldien
    El Hawary, Ahmed
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (10) : 1463 - 1472
  • [32] In-stent restenosis in a polytetrafluoroethylene covered stent combined with drug eluting stents: potential pathogenesis revealed by optical coherence tomography
    Yang, Qing
    Liu, Wei
    Fang, Fang
    Yu, Cheuk-Man
    Zhou, Yu-Jie
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 198 : 42 - 44
  • [33] Comparison of Efficacy and Safety between Sirolimus, Paclitaxel, Everolimus-Eluting Stent and SeQuent™ Please, a Drug-Eluting Balloon on the Outcome of Patients with Diffuse In-Stent Restenosis after Bare Metal Stent Implantation
    Nakamura, Sunao
    Ogawa, Hisao
    Bae, Jang-Ho
    Cahyadi, Yeo H.
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    CIRCULATION, 2010, 122 (21)
  • [34] Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis
    Miura, Katsuya
    Tada, Takeshi
    Habara, Seiji
    Kuwayama, Akimune
    Shimada, Takenobu
    Ohya, Masanobu
    Murai, Ryosuke
    Amano, Hidewo
    Kubo, Shunsuke
    Otsuru, Suguru
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Kadota, Kazushige
    CIRCULATION JOURNAL, 2018, 82 (11) : 2820 - +
  • [35] Optical coherence tomography characteristics of in-stent restenosis after drug-eluting stent implantation: a novel classification and its clinical significance
    Wataru Yamamoto
    Kenichi Fujii
    Satoru Otsuji
    Shin Takiuchi
    Mikio Kakishita
    Motoaki Ibuki
    Katsuyuki Hasegawa
    Kasumi Ishibuchi
    Hiroto Tamaru
    Shingo Yasuda
    Rui Ishii
    Sho Nakabayashi
    Hirofumi Kusumoto
    Yorihiko Higashino
    Heart and Vessels, 2020, 35 : 38 - 45
  • [36] Long-Term Efficacy and Safety of Paclitaxel-Eluting Balloon for the Treatment of Drug-Eluting Stent Restenosis 3-Year Results of a Randomized Controlled Trial
    Kufner, Sebastian
    Cassese, Salvatore
    Valeskini, Marco
    Neumann, Franz-Josef
    Schulz-Schuepke, Stefanie
    Hoppmann, Petra
    Fusaro, Massimiliano
    Schunkert, Heribert
    Laugwitz, Karl-Ludwig
    Kastrati, Adnan
    Byrne, Robert A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (07) : 877 - 884
  • [37] Drug-Coated Balloons Versus Drug-Eluting Stents or Plain Old Balloon Angioplasty: A Long-Term in-Stent Restenosis Study
    von Koch, Sacharias
    Zhou, Mikael
    Rosen, Hans Christian
    Zwackman, Sammy
    Jurga, Juliane
    Grimfjard, Per
    Gotberg, Matthias
    Mohammad, Moman A.
    Erlinge, David
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (23):
  • [38] Cost-effectiveness of paclitaxel-coated balloon angioplasty and paclitaxel-eluting stent implantation for treatment of coronary in-stent restenosis in patients with stable coronary artery disease
    Bonaventura, Klaus
    Leber, Alexander W.
    Sohns, Christian
    Roser, Mattias
    Boldt, Leif-Hendrik
    Kleber, Franz X.
    Haverkamp, Wilhelm
    Dorenkamp, Marc
    CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (07) : 573 - 584
  • [39] Inflammation inhibitory effects of sirolimus and paclitaxel-eluting stents on interleukin-1β-induced coronary artery in-stent restenosis in pigs
    Zhou Xu-chen
    Huang Rong-chong
    Zhang Bo
    Yin Da
    Liang Bin
    Wang Shao-peng
    Guan Qi-gang
    Sun Xi-zhuo
    Miao Zhi-lin
    He Xue-zhi
    Han Feng-tong
    Cheng Ying
    Zhang Li
    Zeng Ding-yin
    CHINESE MEDICAL JOURNAL, 2010, 123 (17) : 2405 - 2409
  • [40] Paclitaxel-Eluting Balloon Versus Standard Balloon Angioplasty in In-Stent Restenosis of the Superficial Femoral and Proximal Popliteal Artery 1-Year Results of the PACUBA Trial
    Kinstner, Christian M.
    Lammer, Johannes
    Willfort-Ehringer, Andrea
    Matzek, Wolfgang
    Gschwandtner, Michael
    Javor, Domagoj
    Funovics, Martin
    Schoder, Maria
    Koppensteiner, Renate
    Loewe, Christian
    Ristl, Robin
    Wolf, Florian
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (13) : 1386 - 1392