Characteristics of a tapered undulator for the X-ray absorption fine-structure technique at PLS-II

被引:4
作者
Sung, Nark-Eon [1 ]
Lee, Ik-Jae [1 ]
Jeong, Sung-hoon [1 ]
Kang, Seen-Woong [1 ]
机构
[1] Pohang Univ Sci & Technol, Pohang Accelerator Lab, Pohang 790834, South Korea
来源
JOURNAL OF SYNCHROTRON RADIATION | 2014年 / 21卷
基金
新加坡国家研究基金会;
关键词
undulator; high-order harmonic; X-ray absorption fine structure; gap-scan mode; tapered mode; PHOTON SOURCE; BEAMLINE; XAFS; SPECTROSCOPY; PERFORMANCE; RADIATION; SPRING-8; WIGGLER; DESIGN; ESRF;
D O I
10.1107/S1600577514015549
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An in-vacuum undulator (IVU) with a tapered configuration was installed in the 8C nanoprobe/XAFS beamlime (BL8C) of the Pohang Light Source in Korea for hard X-ray nanoprobe and X-ray absorption fine-structure (XAFS) experiments. It has been operated in planar mode for the nanoprobe experiments, while gap-scan and tapered modes have been used alternatively for XAFS experiments. To examine the features of the BL8C IVU for XAFS experiments, spectral distributions were obtained theoretically and experimentally as functions of the gap and gap taper. Beam profiles at a cross section of the X-ray beam were acquired using a slit to visualize the intensity distributions which depend on the gap, degree of tapering and harmonic energies. To demonstrate the effect of tapering around the lower limit of the third-harmonic energy, V K-edge XAFS spectra were obtained in each mode. Owing to the large X-ray intensity variation around this energy, XAFS spectra of the planar and gap-scan modes show considerable spectral distortions in comparison with the tapered mode. This indicates that the tapered mode, owing to the smooth X-ray intensity profile at the expense of the highest and most stable intensity, can be an alternative for XAFS experiments where the gap-scan mode gives a considerable intensity variation; it is also suitable for quick-XAFS scanning.
引用
收藏
页码:1282 / 1287
页数:6
相关论文
共 31 条
  • [21] XAFS and X-MCD spectroscopies with undulator gap scan
    Rogalev, A
    Gotte, V
    Goulon, J
    Gauthier, C
    Chavanne, J
    Elleaume, P
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 989 - 991
  • [22] Performance upgrade in the JAEA actinide science beamline BL23SU at SPring-8 with a new twin-helical undulator
    Saitoh, Yuji
    Fukuda, Yoshihiro
    Takeda, Yukiharu
    Yamagami, Hiroshi
    Takahashi, Sunao
    Asano, Yoshihiro
    Hara, Toru
    Shirasawa, Katsutoshi
    Takeuchi, Masao
    Tanaka, Takashi
    Kitamura, Hideo
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 388 - 393
  • [23] THE USE OF A SINGLE WAVELENGTH WIGGLER IN PEP AS A CIRCULAR POLARIZED HARD X-RAY SOURCE
    SASAKI, S
    YOUNGMAN, B
    WINICK, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2) : 401 - 407
  • [24] New XAFS beamline for structural and electronic dynamics of nanoparticle catalysts in fuel cells under operating conditions
    Sekizawa, O.
    Uruga, T.
    Tada, M.
    Nitta, K.
    Kato, K.
    Tanida, H.
    Takeshita, K.
    Takahashi, S.
    Sano, M.
    Aoyagi, H.
    Watanabe, A.
    Nariyama, N.
    Ohashi, H.
    Yumoto, H.
    Koyama, T.
    Senba, Y.
    Takeuchi, T.
    Furukawa, Y.
    Ohata, T.
    Matsushita, T.
    Ishizawa, Y.
    Kudo, T.
    Kimura, H.
    Yamazaki, H.
    Tanaka, T.
    Bizen, T.
    Seike, T.
    Goto, S.
    Ohno, H.
    Takata, M.
    Kitamura, H.
    Ishikawa, T.
    Yokoyama, T.
    Iwasawa, Y.
    [J]. 15TH INTERNATIONAL CONFERENCE ON X-RAY ABSORPTION FINE STRUCTURE (XAFS15), 2013, 430
  • [25] THEORY OF MULTICOMPONENT WIGGLER FREE-ELECTRON LASERS IN THE SMALL-SIGNAL REGIME
    SHIH, CC
    CAPONI, MZ
    [J]. PHYSICAL REVIEW A, 1982, 26 (01) : 438 - 450
  • [26] Status of the Nanoscopium Scanning Hard X-ray Nanoprobe Beamline of Synchrotron Soleil
    Somogyi, A.
    Kewish, C. M.
    Ribbens, M.
    Moreno, T.
    Polack, F.
    Baranton, G.
    Desjardins, K.
    Samama, J. P.
    [J]. 11TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY (XRM2012), 2013, 463
  • [27] Takahashi K., 2013, PHYS C SER, V425
  • [28] Synchronous scanning of undulator gap and monochromator for XAFS measurements in soft x-ray region
    Tanaka, T
    Matsubayashi, N
    Imamura, M
    Shimada, H
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 : 345 - 347
  • [29] X-ray absorption spectroscopy of diluted system by undulator photon source and multi-element solid-state detector
    Tanida, H
    Ishii, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 (PART II) : 1564 - 1567