Characteristics of a tapered undulator for the X-ray absorption fine-structure technique at PLS-II

被引:4
作者
Sung, Nark-Eon [1 ]
Lee, Ik-Jae [1 ]
Jeong, Sung-hoon [1 ]
Kang, Seen-Woong [1 ]
机构
[1] Pohang Univ Sci & Technol, Pohang Accelerator Lab, Pohang 790834, South Korea
来源
JOURNAL OF SYNCHROTRON RADIATION | 2014年 / 21卷
基金
新加坡国家研究基金会;
关键词
undulator; high-order harmonic; X-ray absorption fine structure; gap-scan mode; tapered mode; PHOTON SOURCE; BEAMLINE; XAFS; SPECTROSCOPY; PERFORMANCE; RADIATION; SPRING-8; WIGGLER; DESIGN; ESRF;
D O I
10.1107/S1600577514015549
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An in-vacuum undulator (IVU) with a tapered configuration was installed in the 8C nanoprobe/XAFS beamlime (BL8C) of the Pohang Light Source in Korea for hard X-ray nanoprobe and X-ray absorption fine-structure (XAFS) experiments. It has been operated in planar mode for the nanoprobe experiments, while gap-scan and tapered modes have been used alternatively for XAFS experiments. To examine the features of the BL8C IVU for XAFS experiments, spectral distributions were obtained theoretically and experimentally as functions of the gap and gap taper. Beam profiles at a cross section of the X-ray beam were acquired using a slit to visualize the intensity distributions which depend on the gap, degree of tapering and harmonic energies. To demonstrate the effect of tapering around the lower limit of the third-harmonic energy, V K-edge XAFS spectra were obtained in each mode. Owing to the large X-ray intensity variation around this energy, XAFS spectra of the planar and gap-scan modes show considerable spectral distortions in comparison with the tapered mode. This indicates that the tapered mode, owing to the smooth X-ray intensity profile at the expense of the highest and most stable intensity, can be an alternative for XAFS experiments where the gap-scan mode gives a considerable intensity variation; it is also suitable for quick-XAFS scanning.
引用
收藏
页码:1282 / 1287
页数:6
相关论文
共 31 条
  • [11] The characterization of undulator radiation at MAXII using a soft X-ray fluorescence spectrometer
    Guo, JH
    Butorin, SM
    Såthe, C
    Nordgren, J
    Bässler, M
    Feifel, R
    Werin, S
    Georgsson, M
    Åndersson, A
    Jurvansuu, M
    Nyholm, R
    Eriksson, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (1-2) : 285 - 293
  • [12] The beamline ID24 at ESRF for energy dispersive X-ray absorption spectroscopy
    Hagelstein, M
    San Miguel, A
    Fontaine, A
    Goulon, J
    [J]. JOURNAL DE PHYSIQUE IV, 1997, 7 (C2): : 303 - 308
  • [13] New high-brilliance beamline BL-15A of the Photon Factory
    Igarashi, N.
    Shimizu, N.
    Koyama, A.
    Mori, T.
    Ohta, H.
    Niwa, Y.
    Nitani, H.
    Abe, H.
    Nomura, M.
    Shioya, T.
    Tsuchiya, K.
    Ito, K.
    [J]. 11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [14] Time-resolved dispersive XAFS instrument at NW2A beamline of PF-AR
    Inada, Y.
    Suzuki, A.
    Niwa, Y.
    Nomura, M.
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1230 - +
  • [16] SHORT-PERIOD HELICAL WIGGLER AS AN IMPROVED SOURCE OF SYNCHROTRON RADIATION
    KINCAID, BM
    [J]. JOURNAL OF APPLIED PHYSICS, 1977, 48 (07) : 2684 - 2691
  • [17] Performance of a fixed-taper in-vacuum undulator at SPring-8
    Marechal, XM
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 401 - 402
  • [18] Design and performance of an X-ray undulator beamline PF-AR-NW2
    Mori, T
    Nomura, A
    Sato, A
    Adachi, H
    Uchida, Y
    Toyoshima, A
    Yamamoto, S
    Tsuchiya, K
    Shioya, T
    Kawata, H
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 255 - 258
  • [19] Quick-scanning x-ray absorption spectroscopy system with a servo-motor-driven channel-cut monochromator with a temporal resolution of 10 ms
    Nonaka, T.
    Dohmae, K.
    Araki, T.
    Hayashi, Y.
    Hirose, Y.
    Uruga, T.
    Yamazaki, H.
    Mochizuki, T.
    Tanida, H.
    Goto, S.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (08)
  • [20] Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8
    Oyanagi, H
    Ishii, M
    Lee, CH
    Saini, NL
    Kuwahara, Y
    Saito, A
    Izumi, Y
    Hashimoto, H
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (02) : 89 - 94