Fragmentation analysis by superconducting ion detectors in matrix-assisted laser desorption/ionization (MALDI)

被引:19
作者
Ohkubo, M [1 ]
Shigeri, Y [1 ]
Kinumi, T [1 ]
Saito, N [1 ]
Ukibe, M [1 ]
Chen, YE [1 ]
Kushino, A [1 ]
Kurokawa, A [1 ]
Sato, H [1 ]
Ichimura, S [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, AIST, Tsukuba, Ibaraki 3058568, Japan
关键词
superconducting tunnel junction; mass spectroscopy; post-source decay;
D O I
10.1016/j.nima.2005.12.137
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fragmentation of precursor ions of peptides or proteins is very promising for sequencing with matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry (TOF-MS). Neutral fragments Lis well Lis ions produced by post-source decay (PSD) were measured by a superconducting tunnel junction detector in a linear TOF-MS. It has been demonstrated that the PSD fragments are observable as event bands with different kinetic energies at the same TOF as that of the precursor ions of polystyrene with a nominal mass of 200 kDa and bovine serum albumin of 66.43 kDa. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:779 / 781
页数:3
相关论文
共 12 条
[1]  
Frank M, 1999, MASS SPECTROM REV, V18, P155, DOI 10.1002/(SICI)1098-2787(1999)18:3/4<155::AID-MAS1>3.3.CO
[2]  
2-N
[3]   Impact energy measurement in time-of-flight mass spectrometry with cryogenic microcalorimeters [J].
Hilton, GC ;
Martinis, JM ;
Wollman, DA ;
Irwin, KD ;
Dulcie, LL ;
Gerber, D ;
Gillevet, PM ;
Twerenbold, D .
NATURE, 1998, 391 (6668) :672-675
[4]   POSSIBILITY OF HIGH-RESOLUTION DETECTORS USING SUPERCONDUCTING TUNNEL-JUNCTIONS [J].
KURAKADO, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 196 (01) :275-277
[5]   Effects of spatial nonuniformity of superconducting-tunnel-junction ion detectors on mass Spectroscopy [J].
Ohkubo, M ;
Ukibe, M ;
Saito, N ;
Kushino, A ;
Ichimura, S ;
Friedrich, S .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :932-935
[6]  
Spengler B, 1997, J MASS SPECTROM, V32, P1019, DOI 10.1002/(SICI)1096-9888(199711)32:10<1019::AID-JMS595>3.0.CO
[7]  
2-G
[8]  
Tanaka K., 1988, RAPID COMMUN MASS SP, V2, P151, DOI DOI 10.1002/RCM.1290020802
[9]   Detection of single macromolecules using a cryogenic particle detector coupled to a biopolymer mass spectrometer [J].
Twerenbold, D ;
Vuilleumier, JL ;
Gerber, D ;
Tadsen, A ;
vandenBrandt, B ;
Gillevet, PM .
APPLIED PHYSICS LETTERS, 1996, 68 (24) :3503-3505
[10]   Analysis of megadalton ions using cryodetection MALDI time-of-flight mass spectrometry [J].
Wenzel, RJ ;
Matter, U ;
Schultheis, L ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4329-4337