Silver nanodendrite modified graphene rotating disk electrode for nonenzymatic hydrogen peroxide detection

被引:36
作者
Sawangphruk, Montree [1 ,2 ]
Sanguansak, Yanisa [1 ]
Krittayavathananon, Atiweena [1 ]
Luanwuthi, Santamon [1 ]
Srimuk, Pattarachai [1 ]
Nilmoung, Sukanya [3 ]
Maensiri, Santi [3 ]
Meevasana, Worawat [3 ]
Limtrakul, Jumras [2 ,4 ,5 ,6 ]
机构
[1] Kasetsart Univ, Dept Chem Engn, Natl Ctr Excellence Petr Petrochem & Adv Mat, Fac Engn, Bangkok 10900, Thailand
[2] Kasetsart Univ, Ctr Adv Studies Nanotechnol & Its Applicat Chem F, Bangkok 10900, Thailand
[3] Suranaree Univ, Inst Sci, Sch Phys, Nakhon Ratchasima 30000, Thailand
[4] Kasetsart Univ, Dept Chem, Bangkok 10900, Thailand
[5] Kasetsart Univ, NANOTEC Ctr Nanoscale Mat Design Green Nanotechno, Bangkok 10900, Thailand
[6] PTT Publ Co Ltd, PTT Grp Frontier Res Ctr, Bangkok 10900, Thailand
关键词
GLASSY-CARBON ELECTRODE; AG NANOPARTICLES; SUBSEQUENT DECORATION; FACILE SYNTHESIS; DENDRITIC NANOSTRUCTURES; REPLACEMENT REACTION; OXIDE NANOCOMPOSITE; STABILIZING AGENT; GRAPHITE OXIDE; RAMAN-SPECTRA;
D O I
10.1016/j.carbon.2014.01.010
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Although silver nanostructures have been widely used for H2O2 detection, the development of silver based nanomaterials with higher performance toward H2O2 detection is still needed. In this work, metallic silver nanodendrite (AgND) modified reduced graphene oxide (rGO) electrode with open pore structure was prepared by an electrodeposition method and used for H2O2 detection. The rotating disk electrode (RDE) was used to study the convective diffusion effect of H2O2 to the electrode. The performance of the AgND/rGO electrode toward H2O2 detection significantly depends on the rotation rate of the electrode. At the rotation rates of 0 and 100 rpm, the as-fabricated electrode could not detect H2O2. At higher rotation rates, wide linear ranges of detected H2O2 concentrations with a determination coefficient R-2 of over 0.99 are found to be 1-100, 0.5-100, 0.1-100, and 0.05-30 mM at the electrode rotation rates of 500, 1000, 2000, and 6000 rpm, respectively. The LOD values determined at a signal-to-noise ratio of ca. 3 are about 100, 50, 30, and 10 mu M at 500, 1000, 2000, and 6000 rpm, respectively. The as-fabricated electrode can detect diluted H2O2 in milk demonstrating its potential sensing application. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 45 条
  • [1] Photocatalytic synthesis of silver dendrites using electrostatic hybrid films of porphyrin-polyoxometalate
    Ahmed, Iftikhar
    Wang, Xiaoxia
    Boualili, Nadia
    Xu, Hualong
    Farha, Rana
    Goldmann, Michel
    Ruhlmann, Laurent
    [J]. APPLIED CATALYSIS A-GENERAL, 2012, 447 : 89 - 99
  • [2] All in the graphene family - A recommended nomenclature for two-dimensional carbon materials
    Bianco, Alberto
    Cheng, Hui-Ming
    Enoki, Toshiaki
    Gogotsi, Yury
    Hurt, Robert H.
    Koratkar, Nikhil
    Kyotani, Takashi
    Monthioux, Marc
    Park, Chong Rae
    Tascon, Juan M. D.
    Zhang, Jin
    [J]. CARBON, 2013, 65 : 1 - 6
  • [3] In situ growth of copper sulfide nanoparticles on ordered mesoporous carbon and their application as nonenzymatic amperometric sensor of hydrogen peroxide
    Bo, Xiangjie
    Bai, Jing
    Wang, Lixia
    Guo, Liping
    [J]. TALANTA, 2010, 81 (1-2) : 339 - 345
  • [4] Noncovalent functionalization of graphene with end-functional polymers
    Choi, Eun-Young
    Han, Tae Hee
    Hong, Jihyun
    Kim, Ji Eun
    Lee, Sun Hwa
    Kim, Hyun Wook
    Kim, Sang Ouk
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2010, 20 (10) : 1907 - 1912
  • [5] The chemistry of graphene oxide
    Dreyer, Daniel R.
    Park, Sungjin
    Bielawski, Christopher W.
    Ruoff, Rodney S.
    [J]. CHEMICAL SOCIETY REVIEWS, 2010, 39 (01) : 228 - 240
  • [6] Detection of hydrogen peroxide at mesoporous platinum microelectrodes
    Evans, SAG
    Elliott, JM
    Andrews, LM
    Bartlett, PN
    Doyle, PJ
    Denuault, G
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (06) : 1322 - 1326
  • [7] Dendritic silver nanostructure growth and evolution in replacement reaction
    Fang, Jixiang
    You, Hongjun
    Kong, Peng
    Yi, Yan
    Song, Xiaoping
    Ding, Bingjun
    [J]. CRYSTAL GROWTH & DESIGN, 2007, 7 (05) : 864 - 867
  • [8] Interpretation of Raman spectra of disordered and amorphous carbon
    Ferrari, AC
    Robertson, J
    [J]. PHYSICAL REVIEW B, 2000, 61 (20) : 14095 - 14107
  • [9] Facile synthesis of Ag dendrites on Al foil via galvanic replacement reaction with [Ag(NH3)2]Cl for ultrasensitive SERS detecting of biomolecules
    Fu, Jiajia
    Ye, Weichun
    Wang, Chunming
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2013, 141 (01) : 107 - 113
  • [10] Effect of silver nanoparticles on the electron transfer reactivity and the catalytic activity of myoglobin
    Gan, X
    Liu, T
    Zhong, J
    Liu, XJ
    Li, GX
    [J]. CHEMBIOCHEM, 2004, 5 (12) : 1686 - 1691