Screw-tip augmentation versus standard locked plating of displaced proximal humeral fractures: a retrospective comparative cohort study

被引:18
作者
Siebenbuerger, Georg [1 ]
Helfen, Tobias [1 ]
Biermann, Niklas [1 ]
Haasters, Florian [2 ]
Boecker, Wolfgang [1 ]
Ockert, Ben [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Munich Univ Hosp, Dept Gen Trauma & Reconstruct Surg, Shoulder & Elbow Serv, Nussbaumstr 30, D-80336 Munich, Germany
[2] Schon Klin Munchen Harlaching, Dept Knee Hip & Shoulder Surg, Munich, Germany
关键词
Proximal humeral fracture; locked plating; PMMA; augmentation; osteosynthesis; avascular necrosis; loss of fixation; ANGULAR STABLE PLATE; INTERNAL-FIXATION; OPEN REDUCTION; CEMENT; CLASSIFICATION; SHOULDER; QUALITY;
D O I
10.1016/j.jse.2018.12.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study compared the clinical and radiologic outcomes of screw tip-augmented locking plate osteosynthesis vs. standard locked plating in elderly patients with displaced proximal humeral fractures. Methods: Of the 94 patients older than 65 years with displaced proximal humeral fractures. 55 underwent fixation with a locking plate only whereas 39 underwent fixation using a locking plate with fluoroscopy-controlled polymethyl methacrylate augmentation of screw tips. Results: At 2 years' follow-up, the locking plate-only group showed a mean Constant score (CS) of 62.6 +/- 17.4 points, mean CS as a percentage of the uninjured side of 78.2% +/- 18.9%, and mean age- and sex-adjusted CS of 72.4 +/- 20.5 points. Among the 39 patients who underwent locked plating with polymethyl methacrylate augmentation of screw tips. the mean CS was 63.7 +/- 18.5 points (P = .28), the mean CS as a percentage of the uninjured side was 79.5% +/- 20.4% (P = .36), and the mean age- and sex-adjusted CS was 76.8 +/- 26.2 points (P = .11). The mean Disabilities of the Ann, Shoulder and Hand score was 26.4 +/- 21.3 in the locking plate-only group compared with 23.6 +/- 19.2 in the group with screw tip-augmented locking plate osteosynthesis (P = .41). The overall complication rate was 16.3% in the locking plate only group compared with 12.8% in the group with screw tip augmented osteosynthesis (P = .86); loss of fixation occurred in 10.9% vs. 5.1% (P = .74). The follow-up rate was 81%. Conclusions: Loss of fixation was less frequent when augmentation of screw tips was performed; however, at the 2-year follow-up, the clinical and radiologic outcomes were not significantly different compared with standard locked plating without augmentation. (C) 2019 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1326 / 1333
页数:8
相关论文
共 32 条
  • [1] Trends and Variation in Incidence, Surgical Treatment, and Repeat Surgery of Proximal Humeral Fractures in the Elderly
    Bell, John-Erik
    Leung, Brian C.
    Spratt, Kevin F.
    Koval, Ken J.
    Weinstein, James D.
    Goodman, David C.
    Tosteson, Anna N. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (02) : 121 - 131
  • [2] In vitro temperature evaluation during cement augmentation of proximal humerus plate screw tips
    Blazejak, Marek
    Hofmann-Fliri, Ladina
    Buechler, Lorenz
    Gueorguiev, Boyko
    Windolf, Markus
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10): : 1321 - 1326
  • [3] A review of the Constant score: Modifications and guidelines for its use
    Constant, Christopher R.
    Gerber, Christian
    Emery, Rogerj. H.
    Solbjerg, Jens Ole
    Boileau, Pascal
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (02) : 355 - 361
  • [4] CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
  • [5] Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures
    Egol, Kenneth A.
    Sugi, Michelle T.
    Ong, Crispin C.
    Montero, Nicole
    Davidovitch, Roy
    Zuckerman, Joseph D.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (06) : 741 - 748
  • [6] Humeral head necrosis rate at mid-term follow-up after open reduction and angular stable plate fixation for proximal humeral fractures
    Greiner, S.
    Kaeaeb, M. J.
    Haas, N. P.
    Bail, H. J.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (02): : 186 - 191
  • [7] Haasters F, 2014, OSTEOLOGIE, V23, P16
  • [8] Osteonecrosis of the humeral head: Relationship of disease stage, extent, and cause to natural history
    Hattrup, SJ
    Cofield, RH
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 1999, 8 (06) : 559 - 564
  • [9] Hudak PL, 1996, AM J IND MED, V29, P602, DOI 10.1002/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO
  • [10] 2-L