Energy and exergy analysis of domestic refrigerators using R152a to replace R134a

被引:13
|
作者
Chen, Xinwen [1 ]
Liang, Kun [1 ,2 ]
Li, Zhaohua [1 ]
Jiang, Hanying [2 ]
Xu, Jing [1 ]
机构
[1] Yangzhou Univ, Dept Mech Engn, Yangzhou 225012, Jiangsu, Peoples R China
[2] Univ Sussex, Dept Engn & Design, Brighton BN1 9QT, E Sussex, England
关键词
Oil-free refrigerator; Energy efficiency ratio; Normalised COP; Total exergy destruction; Exergy efficiency; PERFORMANCE; AIR; ALTERNATIVES; R1234ZE(E); R1234YF; R290;
D O I
10.1016/j.tsep.2022.101235
中图分类号
O414.1 [热力学];
学科分类号
摘要
R152a has similar thermodynamic properties to R134a and can be used as one of the alternative refrigerants to R134a. However, flammability restricts the use of R152a in conventional domestic refrigerators. The oil-free VCR system allows the elimination of lubricating oil and therefore reduces the refrigerant charge, thus allowing a reasonable level of safety to be achieved with R152a. This study tests the performance of R152a and R134a in an oil-free domestic refrigerator under various operating conditions. The oil-free VCR system is made up of two oil free linear compressors with strokes of 0-14 mm, a water-cooled coaxial condenser, an expansion valve and an evaporator with an electric heater. The results show that R152a has an average energy efficiency ratio (EER) that is about 26% higher than R134a. Furthermore, the total exergy destruction of R134a is 9% higher than R152a on average due to a higher vapour density. The lower total exergy destruction allows the VCR system using R152a to achieves an exergy efficiency 7% higher than R134a on average. This paper also reports the experimental results of power input, volumetric efficiency, mass flow rate, normalised coefficient of performance (COP) and isentropic efficiency. It can be concluded that R152a can replace R134a in the oil-free domestic refrigerator.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Experimental study of R152a and R32 to replace R134a in a domestic refrigerator
    Bolaji, B. O.
    ENERGY, 2010, 35 (09) : 3793 - 3798
  • [2] Hydrocarbons as Alternate Refrigerants to Replace R134a in Domestic Refrigerators
    Siddegowda, Parashurama
    Sannappagowda, Govindegowda Mundur
    Jain, Vaibhav
    Gowda, Satheesh Javare
    REVUE DES COMPOSITES ET DES MATERIAUX AVANCES-JOURNAL OF COMPOSITE AND ADVANCED MATERIALS, 2019, 29 (02): : 95 - 99
  • [3] EXPERIMENTAL PERFORMANCE OF R134a AND R152a USING MICROCHANNEL CONDENSER
    Bhatkar, V. W.
    Kriplani, V. M.
    Awari, G. K.
    JOURNAL OF THERMAL ENGINEERING, 2015, 1 (07): : 575 - 582
  • [5] Energy evaluation of R152a as drop in replacement for R134a in cascade refrigeration plants
    Cabello, R.
    Sanchez, D.
    Llopis, R.
    Catalan, J.
    Nebot-Andres, L.
    Torrella, E.
    APPLIED THERMAL ENGINEERING, 2017, 110 : 972 - 984
  • [6] Heat transfer in nucleate boiling of R134a/R152a mixtures
    Kehong Shi
    Klaus Spindler
    Erich Hahne
    Heat and Mass Transfer, 2010, 46 : 1137 - 1145
  • [7] Heat transfer in nucleate boiling of R134a/R152a mixtures
    Shi, Kehong
    Spindler, Klaus
    Hahne, Erich
    HEAT AND MASS TRANSFER, 2010, 46 (10) : 1137 - 1145
  • [8] R152a/R134a的汽液相平衡分析
    张昌
    制冷, 1995, (02) : 55 - 58
  • [9] Energy Analysis of R1234yf/R134a as Replacement of R134a in a Domestic Refrigerator
    Raveendran, P. Saji
    Murugan, P. C.
    Darwin, T.
    Glivin, Godwin
    Dwivedi, Gaurav
    ADVANCEMENT IN MATERIALS, MANUFACTURING AND ENERGY ENGINEERING, VOL. II, ICAMME 2021, 2022, : 495 - 502
  • [10] Experimental Investigation of Performance of R134a/R152a Refrigerant Mixture in Heat Pump
    Boran, Kurtulus
    Menlik, Tayfun
    Alpsoy, Halil
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2015, 18 (04): : 251 - 256