关键词
Sterilization; Gamma; X-ray; Electron beam; Functional performance; Color change; Polymers;
D O I
10.1016/j.radphyschem.2020.109282
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Effective sterilization methods for single-use devices are a growing need for the medical industry. Concerns with safety, throughput and source availability, however, prompt prudent contingency planning for gamma irradiation of devices suited for radiation sterilization. Electron beam (e-beam) and X-ray represent two alternatives to gamma radiation if they can be confirmed to be compatible with sterilization of the devices. To address this question, the effects of sterilization-relevant doses of e-beam and X-ray radiation are directly compared to the effects of gamma radiation using two prototypical commercial devices currently sterilized using cobalt-60 gamma radiation. These devices include components that comprise six distinct polymer materials commonly used in the medical device industry. The devices investigated are the Becton, Dickinson and Company (BD) Vacutainer (TM) Plus tube, comprised of low-density polyethylene, chlorobutyl rubber, and polyethylene terephthalate components; and the BD Vacutainer (TM) Push Button Blood Collection Set, containing polypropylene, polyolefin elastomer, and polyvinyl chloride components. Changes in functionality, discoloration and select mechanical properties of components of each device were measured following exposure to targeted doses of 15, 35, 50 and 80 kGy. A statistical analysis was performed to determine if the effects of e-beam or X-ray radiation differ from the effects of gamma radiation for the properties considered. No devices were found to fail the functional performance tests at any of the doses considered. Small, but statistically significant differences were observed in device discoloration from e-beam, X-ray and gamma radiation following processing for certain materials at certain dose levels. Both e-beam and X-ray irradiation appear as viable alternatives to gamma irradiation for sterilization of the medical devices and materials considered.
引用
收藏
页数:14
相关论文
共 40 条
  • [11] Thermal properties and radical monitoring after gamma, X-ray, and electron beam irradiation in polyamides
    Krieguer, Blanche
    Ludwig, Nicolas
    Dorey, Samuel
    Dupuy, Nathalie
    Girard, Fabien
    Girard-Perier, Nina
    Kuntz, Florent
    Marque, Sylvain R. A.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2024, 26 (31) : 21222 - 21228
  • [12] Effect of X-ray, gamma ray, and electron beam irradiation on the hygienic and physicochemical qualities of red pepper powder
    Jung, Koo
    Song, Beom-Seok
    Kim, Min Jung
    Moon, Byeong-Geum
    Go, Seon-Min
    Kim, Jae-Kyung
    Lee, Yun-Jong
    Park, Jong-Heum
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2015, 63 (02) : 846 - 851
  • [13] Effect of gamma-ray, electron-beam, and X-ray irradiation on antioxidant activity of mugwort extracts
    Hwang, Ko-Eun
    Ham, Youn-Kyung
    Song, Dong-Heon
    Kim, Hyun-Wook
    Lee, Mi-Ai
    Jeong, Jong-Yeon
    Choi, Yun-Sang
    RADIATION PHYSICS AND CHEMISTRY, 2021, 186
  • [14] Comparison of the Effects of Gamma Ray and Electron Beam Irradiation to Improve Safety of Spices for Meat Processing
    Kim, Byung-Hee
    Kim, Hyun-Joo
    Yoon, Yohan
    Shin, Myung-Gon
    Lee, Ju-Woon
    KOREAN JOURNAL FOR FOOD SCIENCE OF ANIMAL RESOURCES, 2010, 30 (01) : 124 - 132
  • [15] A Comparison of X-Ray Versus Gamma Irradiation of Leukoreduced AS-3 Red Blood Cells
    Packard, J.
    TRANSFUSION, 2010, 50 : 71A - 72A
  • [16] Radiotherapy in the management of keloids - Clinical experience with electron beam irradiation and comparison with X-ray therapy
    Maarouf, M
    Schleicher, U
    Schmachtenberg, A
    Ammon, J
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 (06) : 330 - 335
  • [17] Effect of heterogeneity of subjects of industrial irradiation processes on spatial distributions of absorbed doses upon electron beam, X-ray and gamma irradiation
    Dyuldya, S. V.
    Bratchenko, M. I.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2007, (05): : 81 - 89
  • [18] USE OF DIRECT ELECTRON EXCITATION FOR ANALYSIS OF GEOLOGICAL SAMPLES AND COMPARISON OF THIS TECHNIQUE WITH X-RAY FLUORESCENCE
    STRASHEI.A
    BRANDT, MP
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1970, B 25 (01) : 1 - &
  • [19] Effects of X-ray and electron beam irradiation on wine quality: Emphasizing phenolic compounds and aroma profiles
    Ding, Weikang
    Tu, Qian
    Xi, Xuexue
    Wu, Xiaojie
    Bai, Junqing
    Liu, Shuang
    Li, Junjun
    Yuan, Chunlong
    FOOD CHEMISTRY-X, 2025, 25
  • [20] Effects of electron-beam generated X-ray irradiation on the postharvest storage quality of Agaricus bisporus
    Dong, Shuting
    Guo, Jintao
    Yu, Jiangtao
    Bai, Junqing
    Xu, Huaide
    Li, Mei
    INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2022, 80