The impacts of the thermal radiation field on thermal comfort, energy consumption and control-A critical overview

被引:92
作者
Halawa, Edward [1 ]
van Hoof, Joost [2 ,3 ]
Soebarto, Veronica [4 ]
机构
[1] Charles Darwin Univ, Res Inst Environm & Livelihoods RIEL, Ctr Renewable Energy, Darwin, NT 0909, Australia
[2] Fontys Univ Appl Sci, NL-5631 BN Eindhoven, Netherlands
[3] ISSO, Dutch Bldg Serv Res Inst, NL-3014 DB Rotterdam, Netherlands
[4] Univ Adelaide, Sch Architecture & Built Environm, Adelaide, SA 5005, Australia
关键词
Mean radiant temperature; Thermal radiant field; Radiant asymmetry; Thermal comfort tension; Thermal comfort; Heat balance model; Adaptive model; RADIANT TEMPERATURE; BUILDING SYSTEMS; MODEL;
D O I
10.1016/j.rser.2014.05.040
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Thermal comfort is determined by the combined effect of the six thermal comfort parameters: temperature, air moisture content, thermal radiation, air relative velocity, personal activity and clothing level as formulated by Fanger through his double heat balance equations. In conventional air conditioning systems, air temperature is the parameter that is normally controlled whilst others are assumed to have values within the specified ranges at the design stage. In Fanger's double heat balance equation, thermal radiation factor appears as the mean radiant temperature (MRT), however, its impact on thermal comfort is often ignored. This paper discusses the impacts of the thermal radiation field which takes the forms of mean radiant temperature and radiation asymmetry on thermal comfort, building energy consumption and air-conditioning control. Several conditions and applications in which the effects of mean radiant temperature and radiation asymmetry cannot be ignored are discussed. Several misinterpretations that arise from the formula relating mean radiant temperature and the operative temperature are highlighted, coupled with a discussion on the lack of reliable and affordable devices that measure this parameter. The usefulness of the concept of the operative temperature as a measure of combined effect of mean radiant and air temperatures on occupant's thermal comfort is critically questioned, especially in relation to the control strategy based on this derived parameter. Examples of systems which deliver comfort using thermal radiation are presented. Finally, the paper presents various options that need to be considered in the efforts to mitigate the impacts of the thermal radiant field on the occupants' thermal comfort and building energy consumption. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:907 / 918
页数:12
相关论文
共 77 条
  • [1] Experimental and Theoretical Study of Transient Human Thermal Comfort Response in Convective and Radiative Environments
    Al-Othmani, Mohammad
    Ghali, Kamel
    Ghaddar, Nesreen
    [J]. HVAC&R RESEARCH, 2009, 15 (05): : 855 - 873
  • [2] On the measurement of the mean radiant temperature and its influence on the indoor thermal environment assessment
    Alfano, Francesca Romana d'Ambrosio
    Dell'Isola, Marco
    Palella, Boris Igor
    Riccio, Giuseppe
    Russi, Aldo
    [J]. BUILDING AND ENVIRONMENT, 2013, 63 : 79 - 88
  • [3] [Anonymous], INT J AMBIENT ENERGY
  • [4] [Anonymous], CONT ERGON
  • [5] [Anonymous], THESIS U S AUSTR
  • [6] [Anonymous], P INT C EN US MAN AS
  • [7] [Anonymous], 2002, 77262002 ISO
  • [8] [Anonymous], ENERGY BUILD
  • [9] [Anonymous], 2008, ASHRAE HDB
  • [10] [Anonymous], STANDARD OPERATIVE T