Proximity of coronary arteries to the atrioventricular valve annulus in young patients and implications for ablation procedures

被引:19
作者
Al-Ammouri, Iyad
Perry, James C.
机构
[1] Yale Univ, Sch Med, Pediat Cardiol Sect, New Haven, CT 06520 USA
[2] Univ Calif San Diego, Childrens Hosp San Diego, San Diego, CA 92103 USA
关键词
D O I
10.1016/j.amjcard.2006.01.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The distance from the endocardial surface of the atrioventricular valve annulus and adventia of the adjacent coronary artery (CA) has not been delineated and may play an important role in the risk for CA damage during catheter ablation procedures. This distance was measured in 10 normal pediatric heart specimens at 11 locations around the right and left atrioventricular grooves. The endocardium-to-CA distance varied by age and location, with the shortest distances in the region of the os of the coronary sinus and the greatest distances-in the right anteroseptal area. Excluding right anteroseptal measurements, in the 5 patients < 7 years of age, the endocardium-to-CA distances were :54 mm in 76% and <= 5 mm in 96%. Given lesion sizes during ablation procedures, these distances and their potential relation to the risk for CA damage need to be taken into account during catheter ablation procedures in young patients.
引用
收藏
页码:1752 / 1755
页数:4
相关论文
共 16 条
[1]   Ablation of atrial-ventricular junction tissues via the coronary sinus using cryo balloon technology [J].
Avitall, B ;
Lafontaine, D ;
Rozmus, G ;
Adoni, N ;
Dehnee, A ;
Urbonas, A ;
Le, KM ;
Aleksonis, D .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 12 (03) :203-211
[2]   Determination of lesion size by ultrasound during radiofrequency catheter ablation [J].
Awad, S ;
Eick, O .
BIOMEDIZINISCHE TECHNIK, 2003, 48 (7-8) :197-201
[3]   Coronary artery stenosis after radiofrequency catheter ablation of accessory atrioventricular pathways in children with Ebstein's malformation [J].
Bertram, H ;
Bökenkamp, R ;
Peuster, M ;
Hausdorf, G ;
Paul, T .
CIRCULATION, 2001, 103 (04) :538-543
[4]   Acute coronary artery stenosis during slow pathway ablation for atrioventricular nodal reentrant tachycardia in a child [J].
Blaufox, AD ;
Saul, JP .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (01) :97-100
[5]   Effects of intracardiac radiofrequency current application on coronary artery vessels in young pigs [J].
Bökenkamp, R ;
Wibbelt, G ;
Sturm, M ;
Windhagen-Mahnert, B ;
Bertram, H ;
Hausdorf, G ;
Paul, T .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (05) :565-571
[6]   Effects of radiofrequency pulses delivered in the vicinity of the coronary arteries: Implications for nonsurgical transthoracic epicardial catheter ablation to treat ventricular tachycardia [J].
D'Avila, A ;
Gutierrez, P ;
Scanavacca, M ;
Reddy, V ;
Lustgarten, DL ;
Sosa, E ;
Ramires, JAF .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (10) :1488-1495
[7]   Temperature monitoring during radiofrequency ablation [J].
Dinerman, JL ;
Berger, RD ;
Calkins, H .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (02) :163-173
[8]  
Duong Truong, 2004, J Invasive Cardiol, V16, P657
[9]  
Khanal S, 1999, CATHETER CARDIO INTE, V46, P59, DOI 10.1002/(SICI)1522-726X(199901)46:1<59::AID-CCD16>3.0.CO
[10]  
2-8