Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers

被引:50
作者
De la Parra-Colin, Paola
Garza-Leon, Manuel
Barrientos-Gutierrez, Tonatiuh
机构
[1] Cornea and Ocular Surface Clinic, Ophthalmology Department, IMSS (Mexican Institute of Social Security), Mexico City
[2] Destellos de Luz Non-Profit Foundation, Monterrey City
[3] Institute for Sight Preservation, Monterrey City
[4] Center for Population Health Research, National Institute of Public Health, Mexico City
[5] Center for Integrative Approaches to Population Health, University of Michigan, Ann Arbor, MI
关键词
CHAMBER DEPTH MEASUREMENTS; CORNEAL THICKNESS MEASUREMENT; ULTRASOUND PACHYMETRY; OCULUS PENTACAM; ORBSCAN II; AGREEMENT; REPRODUCIBILITY; TOPOGRAPHY; GALILEI; EYES;
D O I
10.1007/s10792-013-9780-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess the repeatability and comparability of six anterior segment biometry parameters obtained with a novel Scheimpflug camera with a Placido disc topographer (Sirius) and slit-scanning tomography with a Scheimpflug camera (Pentacam), in a sample of 16 unoperated eyes of healthy subjects. The anterior segment was analyzed by a single examiner using the Sirius and the Pentacam analyzers. Mean simulated keratometry (Sim K), flat and steep axis keratometry (K (f) and K (s) ), central and thinnest corneal thicknesses (CCT and TCT), and anterior chamber depth (ACD) measurements were evaluated. Repeatability of three sets of measurements from each device was assessed using the coefficient of variation (CV), within-subject standard deviation, and intraclass correlation coefficient (ICC). Bonferroni-adjusted t-tests, and Bland and Altman plots were used to establish agreement between devices. For both devices the CV of repeated measurements was < 0.79 %. The ICC was > 0.95 in all measurements except for Sirius K (s) (ICC = 0.869). For all parameters evaluated, the Pentacam systematically yielded higher values, although differences were statistically significant in only three parameters-0.31 diopters for K (s) , 10.1 mu m for CCT and 12.4 mu m for TCT. In the assessment of normal corneas both devices showed overall high repeatability. Although good agreement was found in three parameters (Sim K, K (f) and ACD) these devices do not seem to be interchangeable for pachymetric determination.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 18 条
[1]   Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry [J].
Al-Mezaine H.S. ;
Al-Amro S.A. ;
Kangave D. ;
Sadaawy A. ;
Wehaib T.A. ;
Al-Obeidan S. .
International Ophthalmology, 2008, 28 (5) :333-338
[2]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[3]   A NEW VIEW OF INTER-OBSERVER AGREEMENT [J].
BURDOCK, EI ;
FLEISS, JL ;
HARDESTY, AS .
PERSONNEL PSYCHOLOGY, 1963, 16 (04) :373-384
[4]   A corneal model for slit-scanning elevation topography [J].
Cairns, G ;
Collins, A ;
McGhee, CNJ .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (03) :193-204
[5]   Reliability and repeatability of the Pentacam on corneal curvatures [J].
Chen, Davie ;
Lam, Andrew K. C. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (02) :110-118
[6]   Reproductivity and repeatability of central corneal thickness measurement in keratoconus using the rotating scheimpflug camera and ultrasound pachymetry [J].
De Sanctis, Ugo ;
Missolungi, Alessandro ;
Mutani, Bernardo ;
Richiardi, Lorenzo ;
Grignolo, Federico M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) :712-718
[7]   Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography [J].
Feng, YW ;
Varikooty, J ;
Simpson, TL .
CORNEA, 2001, 20 (05) :480-483
[8]   Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement [J].
Kawamorita, Takushi ;
Uozato, Hiroshi ;
Kamiya, Kazutaka ;
Bax, Leon ;
Tsutsui, Kenta ;
Aizawa, Daisuke ;
Shimizu, Kimiya .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :127-133
[9]   Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound [J].
Lackner, B ;
Schmidinger, G ;
Pieh, S ;
Funovics, MA ;
Skorpik, C .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (10) :892-899
[10]   Validity and Repeatability of Anterior Chamber Depth Measurements With Pentacam and Orbscan [J].
Lackner, Birgit ;
Schmidinger, Gerald ;
Skorpik, Christian .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (09) :858-861