Performance of a helium circulation system for a MEG

被引:7
作者
Takeda, Tsunehiro [1 ]
Okamoto, Masayoshi [1 ]
Atsuda, Kazuhiro [1 ]
Katagiri, Keishi [1 ]
机构
[1] Univ Tokyo, Grad Sch Frontier Sci, Dept Complex Sci & Engn, Chiba 2778561, Japan
关键词
Liquid helium; SQUIDS; Gifford-McMahon; Cryostats; Reuse;
D O I
10.1016/j.cryogenics.2008.12.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
We report the performance of a helium circulation system (HCS) for a magnetoencephalography (MEG) that re-liquefies all the evaporating helium gas using two 1.5 W GM cryocoolers operating at 4.2 K. The MEG with the HCS was used to measure human brain responses for over one and a half years without any noise problems. The noise level is below 10 fr/Hz(1/2) for 2-40 Hz, below 30 fr/Hz(1/2) at 1 Hz, and 200 IT/Hz(1/2) at 50 Hz, which is the power supply frequency. As the amount of liquid helium used decreases less than one percent, the maintenance cost of the MEG becomes less than one-tenth of the previous cost. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 5 条
  • [1] KANG Y, 1998, J JPN BIOMAGNET BIOE, V11, P15
  • [2] TAKEDA T, 2008, BIOMAGNETISM, P36
  • [3] TAKEDA T, J PHYS C SE IN PRESS
  • [4] TAKEDA T, 2004, BIOMAG, P640
  • [5] An efficient helium circulation system with small GM cryocoolers
    Takeda, Tsunehiro
    Okamoto, Masayoshi
    Atsuda, Kazuhiro
    Kobayashi, Aklhiro
    Owaki, Takashi
    Katagiri, Keishi
    [J]. CRYOGENICS, 2008, 48 (1-2) : 6 - 11