QUALITY CONTROL AND ENVIRONMENTAL IMPACT OF HIGH-VOLTAGE INSULATING OILS FOR X-RAY GENERATORS

被引:0
|
作者
Ginovska, M. [1 ]
Spasevska, H. [1 ]
Najdenkoski, K. [1 ]
机构
[1] Fac Elect Engn & Informat Technol, Skopje 1000, Macedonia
来源
关键词
high-voltage insulating oils; X-ray generators; organic contaminators;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
National Implementation Plan for reduction and elimination of persistent organic contaminators in our country, prepared in accordance to the Stockholm Convention, requires identification, detail mapping and quality analysis of transformer oils and liquid dielectrics. Until now, the National Plan gets into consideration as potential contaminants only insulating oils for power transformers in industrial and power systems. Therefore, the need for establishing the mechanisms for quality control and environmental impact of high-voltage insulating oils used in X-ray generators appears. These mechanisms are developed in the Protocol, presented in the paper, as a physical and chemical analysis of new and used oils in X-ray generators. The results from the analysis of several samples of used and new insulating oils show that their quality is correlated with the time of exploitation and working conditions. The analysis of investigated samples clearly show that the presence of polychlorinated biphenyls in used oils could be a signal for introducing a special measures and treatment during the services and maintenance of X-ray generators. The aim of the Protocol is to determine the equipment which could be potential contaminator of environment, to establish regulative for continuous quality control and to introduce environmental, healthy and safe measures for high-voltage insulating oils, used in X-ray generators.
引用
收藏
页码:380 / 385
页数:6
相关论文
共 50 条
  • [21] HIGH-VOLTAGE LAUE X-RAY PHOTOGRAPHY OF LARGE SINGLE CRYSTALS
    PARETZKIN, B
    PEISER, HS
    SCIENCE, 1964, 146 (364) : 260 - &
  • [22] High-voltage shock sparks fusion from X-ray crush
    Geoff Brumfiel
    Nature, 2003, 422 : 549 - 549
  • [23] Transient thermal modelling and validation in high-voltage x-ray sources
    Ma, Nancy
    Morris, Steven A.
    Miller, Eric J.
    Kozaczek, Kris J.
    Jones, Vincent F.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2019, 13
  • [24] HIGH-VOLTAGE TRANSISTOR CONVERTER FOR PULSED X-RAY SOURCES.
    Krasil'nikov, S.B.
    Kristalinskii, A.L.
    Lozovoi, L.N.
    Markov, S.N.
    Sindalovskii, E.I.
    Instruments and experimental techniques New York, 1986, 29 (2 pt 2): : 421 - 422
  • [25] Specific features of high-voltage microfocal medical X-ray diagnosis
    Potrakhov N.N.
    Gryaznov A.Y.
    Biomedical Engineering, 2005, 39 (5) : 221 - 226
  • [26] SUBMICROMETER X-RAY PRINTING WITH X-RAY MASKS DELINEATED BY HIGH-VOLTAGE ELECTRON-BEAM WRITING
    KAWABUCHI, K
    SAKURAI, S
    YOSHIMI, M
    ELECTRONICS LETTERS, 1983, 19 (08) : 287 - 288
  • [27] MEASUREMENT OF PEAK VOLTAGE OF DIAGNOSTIC X-RAY GENERATORS
    DAVISON, M
    REEKIE, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (04): : 643 - &
  • [28] Feasibility Demonstration of High-Voltage Clinical CT and Impact On X-Ray Penetration Through Metal Objects
    Jin, Y.
    Robinson, V.
    Gjesteby, L.
    Wang, G.
    Verburg, J.
    Giantsoudi, D.
    Paganetti, H.
    De Man, B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3720 - 3721
  • [29] The practical peak voltage of diagnostic X-ray generators
    Kramer, HM
    Selbach, HJ
    Iles, WJ
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842): : 200 - 209
  • [30] CALCULATIONS CONCERNING VOLTAGE RIPPLE OF X-RAY GENERATORS
    PORUBSZKY, T