Comparability of dental implant site ridge measurements using ultra-low-dose multidetector row computed tomography combined with filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction

被引:5
作者
Al-Ekrish, Asma'a Abdurrahman [1 ]
Al-Shawaf, Reema [1 ]
Alfaleh, Wafa [1 ]
Hoermann, Romed [2 ]
Puelacher, Wolfgang [3 ]
Widmann, Gerlig [4 ]
机构
[1] King Saud Univ, Coll Dent, Dept Oral Med & Diagnost Sci, Div Oral & Maxillofacial Radiol, POB 60169, Riyadh 11545, Saudi Arabia
[2] Med Univ Innsbruck, Div Clin & Funct Anat, Mullerstr 59, A-6020 Innsbruck, Austria
[3] Med Univ Innsbruck, Dept Craniomaxillofacial Surg, Anichstr 35, A-6020 Innsbruck, Austria
[4] Med Univ Innsbruck, Dept Radiol, Anichstr 35, A-6020 Innsbruck, Austria
关键词
Anatomy; cross-sectional; Image-guided surgery; Imaging; three-dimensional; Multidetector row computed tomography; Radiation dosage; GOVERNING BODY DONATION; CONE-BEAM; LINEAR MEASUREMENTS; CT; ACCURACY; ASIR; REDUCTION; EUROPE; LEGAL; MDCT;
D O I
10.1007/s11282-018-0350-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To assess the linear measurements of edentulous ridges recorded from multidetector row computed tomography (MDCT) images obtained by a previously untested ultra-low dose in combination with filtered back-projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Methods Three cadavers were imaged using a reference protocol with a standard dose and FBP (volume CT dose index (CTDIvol): 29.4 mGy) and two ultra-low-dose protocols, LD1 and LD2 (CTDIvol: 0.53 and 0.29 mGy). All test examinations were reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. Linear measurements from the images of the edentulous ridges recorded from the test protocols were compared with those from the reference using a one-sample t test, Bland-Altman plots, and linear regression. Statistical significance was set at a p value of 0.05. Results The one-sample t test demonstrated a statistically significant difference between the measurements from the reference protocol and all test protocols. The difference was not clinically significant for the following three test protocols: LD1/FBP, LD1/ASIR 50, and LD2/FBP. Bland-Altman plots with linear regression showed no systematic variation between the measurements obtained with the reference protocol and these three test protocols. Conclusions The lowest-dose protocol to demonstrate comparable measurements with a standard MDCT dose was CTDIvol 0.29 mGy with FBP. These results must be considered with caution for areas of the jaws with thin cortication. The results in areas of thin cortication should be verified by studies with larger sample sizes at such areas and comparison with true gold standard measurements.
引用
收藏
页码:280 / 286
页数:7
相关论文
共 23 条
  • [1] A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
    Al-Ekrish, A. A.
    Ekram, M.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) : 67 - 75
  • [2] Do Ultra-Low Multidetector Computed Tomography Doses and Iterative Reconstruction Techniques Affect Subjective Classification of Bone Type at Dental Implant Sites?
    Al-Ekrish, Asma'a A.
    Alfadda, Sara A.
    Tamimi, Dania
    Alfaleh, Wafa
    Hoermann, Romed
    Puelacher, Wolfgang
    Widmann, Gerlig
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (05) : 465 - +
  • [3] Validity of linear measurements of the jaws using ultralow-dose MDCT and the iterative techniques of ASIR and MBIR
    Al-Ekrish, Asma'a A.
    Al-Shawaf, Reema
    Schullian, Peter
    Al-Sadhan, Ra'ed
    Hormann, Romed
    Widmann, Gerlig
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (10) : 1791 - 1801
  • [4] Localization of the inferior alveolar canal using ultralow dose CT with iterative reconstruction techniques
    Al-Ekrish, Asmaa A.
    Alfaleh, Wafa
    Hoermann, Romed
    Alabdulwahid, Ameera
    Puelacher, Wolfgang
    Widmann, Gerlig
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (08)
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro
    Cavalcanti, MGP
    Haller, JW
    Vannier, MW
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (06) : 690 - 694
  • [7] Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning
    Christner, Jodie A.
    Kofler, James M.
    McCollough, Cynthia H.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) : 881 - 889
  • [8] Principles of CT: Multislice CT
    Goldman, Lee W.
    [J]. JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2008, 36 (02) : 57 - 68
  • [9] Kobayashi K, 2004, INT J ORAL MAX IMPL, V19, P228
  • [10] Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units
    Ludlow, J. B.
    Timothy, R.
    Walker, C.
    Hunter, R.
    Benavides, E.
    Samuelson, D. B.
    Scheske, M. J.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (01)