Enabling insights into the maturation of the renin-angiotensin-aldosterone system in children Development of a low-volume LC-MS assay for the simultaneous determination of aldosterone, its precursor, and main metabolite

被引:7
|
作者
Makowski, Nina [1 ]
Burckhardt, Bjoern Bengt [1 ]
机构
[1] Heinrich Heine Univ, Inst Clin Pharm & Pharmacotherapy, Univ Str 1, D-40225 Dusseldorf, Germany
关键词
Aldosterone; 18-Hydroxycorticosterone; Tetrahydroaldosterone; Validation; Mass spectrometry; Low-volume; INFANTS; DIAGNOSIS; IMBALANCE; PLASMA;
D O I
10.1016/j.steroids.2019.04.009
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Introduction: As part of the renin-angiotensin-aldosterone system (RAAS), aldosterone is key to the pathology of cardiovascular and renal diseases, leading to end-organ damage and cardiovascular death. Because of different aetiology and metabolism, pharmacotherapy in adults shows only limited transferability to children. Comprehensive investigations of humoral parameters, their precursors, and metabolites are necessary to establish a more rational and safe therapy in children. The LENA (Labeling of Enalapril from Neonates up to Adolescents) project aims to generate these missing data in neonates up to adolescents and provide insight into the maturing RAAS. Methods: A HRMS (high-resolution mass spectrometry) assay was developed, utilizing blank serum depleted of the endogenous aldosterone, its precursor, 18-hydroxycorticosterone, and its main metabolite, tetrahydroaldosterone. A TOF-MS (time-of-flight-mass spectrometry) scan run in parallel with the simultaneous determination of all three analytes enriches the acquired data. Validation of aldosterone was conducted according to EMA and FDA bioanalytical guidelines. Results: Using the Sciex TripleTOF 6600, a reliable determination in 50 mu L serum was successfully shown. Appropriate calibration ranges from 19.53 pg/mL for aldosterone, 39.06 pg/mL for 18-hydroxycorticosterone, and 78.13 pg/mL for tetrahydroaldosterone to 2500 pg/mL were established to ensure the applicability in diseased paediatric patients. Between-run accuracy and precision for aldosterone ranged between - 1.21 and - 6.99 % and 2.07 and - 10.22 %, respectively, confirming compliance with international guidelines. Conclusion: A simultaneous bioanalytical LC-HRMS assay for the determination of the biomarker aldosterone, its precursor, and main metabolite, utilizing 50 mu L serum, was successfully established. This assay facilitates insight into the maturing RAAS from neonates up to adolescents.
引用
收藏
页码:73 / 81
页数:9
相关论文
共 3 条
  • [1] A LC-MS/MS method for the simultaneous quantitative determination of aldosterone, its precursor 18-hydroxycorticosterone and its metabolite tetrahydroaldosterone in human urine
    Dong, Haohang
    Hu, Bin
    Chen, Wei
    Wang, Liping
    Sun, Huiying
    Zhou, Jianfeng
    Chen, Jianchun
    Chen, Baorong
    Du, Zhenxia
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1234
  • [2] A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based assay for simultaneous quantification of aldosterone, renin activity, and angiotensin II in human plasma
    Chen, Fangjun
    Cheng, Ziyun
    Peng, Yingfei
    Wang, Zhenxin
    Huang, Chao
    Liu, Dan
    Wang, Beili
    Pan, Baishen
    Guo, Wei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1179
  • [3] An LC-MS/MS assay for the quantitative determination of 2-pyridyl acetic acid, a major metabolite and key surrogate for betahistine, using low-volume human K2EDTA plasma
    Soni, Krunal
    Bhatt, Chandrakant
    Singh, Kanchan
    Bhuvaneshwari, P. C.
    Jha, Anil
    Patel, Palak
    Patel, Harilal
    Srinivas, Nuggehally R.
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (02)