HPLC-UV and HPLC-ESI+-MS/MS analysis of free monomeric methylene diphenyl diisocyanate in polyurethane foams and prepolymers after stabilization with NBMA a new derivatizating agent

被引:4
|
作者
Ferreira, Humberto E. [1 ,2 ]
Condeco, Jose A. D. [1 ]
Fernandes, Ines O. [1 ]
Duarte, David E. [1 ]
Bordado, Joao C. M. [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, Dept Engn Quim, Inst Biotecnol & Bioengn, P-1049001 Lisbon, Portugal
[2] Univ Lisbon, Fac Farm, Dept Quim Farmaceut & Terapeut, P-1649003 Lisbon, Portugal
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; DIFFUSIVE SAMPLING METHOD; REACTIVE ISOCYANATE GROUP; ALIPHATIC ISOCYANATES; AIRBORNE ISOCYANATES; TOLUENE DIISOCYANATE; 4,4'-METHYLENEDIPHENYL DIISOCYANATE; COMPLEX-MIXTURES; 1-(2-METHOXYPHENYL)PIPERAZINE DERIVATIVES;
D O I
10.1039/c4ay01163e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The total amount of residual free monomeric methylene diphenyl diisocyanate, fmMDI, in polyurethane foams and prepolymers has been lowered by EU and US EPA legislation due to their harmful effects on human health. A new HPLC method using either UV or mass spectrometry detection has been developed for quantitative analysis of fmMDI. The isocyanate group is stabilized with a new derivatizating amine, N-benzylmethylamine (NBMA), resulting in analytes that are considerably more soluble in solvents routinely used in HPLC than previous methods. The naphthyl isocyanate-NBMA derivative is used as an internal standard, either in the calibration curve method or the standard addition method. Mass spectra of the three compounds of interest (NBMA, fmMDI NBMA derivative, and naphthyl isocyanate NBMA derivative) have been obtained and structural assignment of the major fragment peaks has been accomplished, thus establishing relevant parent-daughter mass transitions in ESI+-MS/MS mode that made the quantitation process highly specific for NBMA derivatives of fmMDI isomers. UV detection uses a wavelength of 254 nm. The HPLC separation is accomplished by columns packed with 5 mm reverse-phase C18 particles. Intra- and inter-day precision for both methods are below the limits established by the Horwitz equation, and the accuracy was measured at 108-111% recovery for both methods. The method does not use toluene, xylene, DMF, DMSO or chlorinated compounds. The use of MS/MS detection considerably reduces the possibility of false or grossly inflated results, avoiding errors that are common in GPC-UV underivatized measurements.
引用
收藏
页码:9242 / 9257
页数:16
相关论文
empty
未找到相关数据