Verification of the use of GEANT4 and MCNPX Monte Carlo codes for calculations of the depth-dose distributions in water for the proton therapy of eye tumours

被引:3
作者
Grzadziel, Maigorzata [1 ]
Konefal, Adam [1 ]
Zipper, Wiktor [1 ]
Pietrzak, Robert [1 ]
Bzymek, Ewelina [1 ]
机构
[1] Univ Silesia, Inst Phys, Dept Nucl Phys & Its Applicat, PL-40007 Katowice, Poland
关键词
depth-doses; GEANT4; MCNPX; therapeutic protons; ENERGY; FACILITY; RADIOTHERAPY; SIMULATION; SPREAD; BEAMS; CT;
D O I
10.2478/nuka-2014-0007
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Verification of calculations of the depth-dose distributions in water, using GEANT4 (version of 4.9.3) and MCNPX (version of 2.7.0) Monte Carlo codes, was performed for the scatterer-phantom system used in the dosimetry measurements in the proton therapy of eye tumours. The simulated primary proton beam had the energy spectra distributed according to the Gauss distribution with the cut at energy greater than that related to the maximum of the spectrum. The energy spectra of the primary protons were chosen to get the possibly best agreement between the measured relative depth-dose distributions along the central-axis of the proton beam in a water phantom and that derived from the Monte Carlo calculations separately for the both tested codes. The local depth-dose differences between results from the calculations and the measurements were mostly less than 5% (the mean value of 2.1% and 3.6% for the MCNPX and GEANT4 calculations). In the case of the MCNPX calculations, the best fit to the experimental data was obtained for the spectrum with maximum at 60.8 MeV (more probable energy), FWHM of the spectrum of 0.4 MeV and the energy cut at 60.85 MeV whereas in the GEANT4 calculations more probable energy was 60.5 MeV, F'WHM of 0.5 MeV, the energy cut at 60.7 MeV. Thus, one can say that the results obtained by means of the both considered Monte Carlo codes are similar but they are not the same. Therefore the agreement between the calculations and the measurements has to be verified before each application of the MCNPX and GEANT4 codes for the determination of the depth-dose curves for the therapeutic protons.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 23 条
[1]  
[Anonymous], 2002, MCNPX USERS MANUAL
[2]  
[Anonymous], 2007, Physics Reference Manual, Geant4 Team
[3]   The clinical impact of uncertainties in the mean excitation energy of human tissues during proton therapy [J].
Besemer, Abigail ;
Paganetti, Harald ;
Bednarz, Bryan .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) :887-902
[4]   Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma [J].
Candela-Juan, Cristian ;
Perez-Calatayud, Jose ;
Ballester, Facundo ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2013, 40 (03)
[5]  
Cirrone G., 2011, Prog Nucl Sci Technol, V2, P207, DOI 10.15669/pnst.2.207
[6]   Individual patient shielding for a proton eye therapy facility [J].
Cywicka-Jakiel, T. ;
Stolarczyk, L. ;
Swakon, J. ;
Olko, P. ;
Waligorski, M. P. R. .
RADIATION MEASUREMENTS, 2010, 45 (10) :1127-1129
[7]   Stopping power and ranges of electrons, protons and alpha particles in liquid water using the Geant4-DNA package [J].
Francis, Z. ;
Incerti, S. ;
Karamitros, M. ;
Tran, H. N. ;
Villagrasa, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (20) :2307-2311
[8]   Molecular Scale Simulation of Ionizing Particles Tracks for Radiobiology and Hadrontherapy Studies [J].
Francis, Ziad .
THEORY OF HEAVY ION COLLISION PHYSICS IN HADRON THERAPY, 2013, 65 :79-110
[9]   Comments on recent measurements of the stopping power of liquid water [J].
Garcia-Molina, Rafael ;
Abril, Isabel ;
de Vera, Pablo ;
Paul, Helmut .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 299 :51-53
[10]  
International Atomic Energy Agency, 2000, TRS398 IAEA