Safe insertion of S-2 alar iliac screws: radiological comparison between 2 insertion points using computed tomography and 3D analysis software

被引:11
作者
Yamada, Kentaro [1 ,2 ]
Abe, Yuichiro [1 ]
Satoh, Shigenobu [1 ]
机构
[1] Wajokai Eniwa Hosp, Dept Orthopaed Surg, Eniwa, Hokkaido, Japan
[2] Osaka City Univ, Dept Orthopaed Surg, Osaka, Japan
关键词
S-2 alar iliac screw; safety margin; pelvic inlet view; 3D analysis software; computed tomography; CT; sacral; PROFILE PELVIC FIXATION; LUMBOPELVIC FIXATION; S2; PLACEMENT; ADULT;
D O I
10.3171/2017.8.SPINE17735
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE S-2 alar iliac (S2AI) screws are commonly used as anchors for lumbosacral fixation A serious potential complication of screw insertion is major vascular injury due to anterior or caudal screw deviation. To avoid screw deviation, the pelvic inlet view on intraoperative fluoroscopy images is recommended. However, there has been no detailed investigation of optimal fluoroscopic incline with the pelvic inlet view. The purpose of this study was to investigate the safety margins and to optimize fluoroscopic settings to avoid screw deviation with 2 reported insertion techniques using 3D analysis software and CT. METHODS The study included 50 patients (25 men and 25 women) who underwent abdominal-pelvic CT. With the use of software, the ideal S2AI screws were set from 2 entry points: A) the midpoint between the S-1 dorsal foramen and the S-2 dorsal foramen where they meet the lateral sacral crest, and B) 1 mm inferior and 1 mm lateral to the S-1 dorsal foramen. Anteriorly or caudally deviated screws were defined as deviation of a half thread of the ideal screw by rotation anteriorly or caudally from the entry point. The angular safety margins were compared between the 2 entry points, and patients with small safety margins were investigated. Subsequently, fluoroscopic images were virtualized on ray sum-rendered images. Conditions that provided proper recognition of screw deviation were investigated via lateral and anteroposterior views with the beam tilted caudally. RESULTS The safety margins of S2AI screws were smaller in the anterior direction than in the caudal direction and by entry point A than by entry point B (A: 9.1 degrees +/- 1.6 degrees and B: 9.7 degrees +/- 1.5 degrees in the anterior direction; A: 10.9 degrees +/- 3.8 degrees and B: 13.9 degrees +/- 4.1 degrees in the caudal direction). In contrast, patients with a deep-seated L-5 vertebral body tended to have smaller safety margins in the caudal direction. All anteriorly deviated screws were recognized with a 60 degrees-70 degrees inlet view from the S-1 slope. The caudally deviated screws were all recognized on the lateral view, but 31% of screws at entry point A and 21% of screws at entry point B were not recognized on the pelvic inlet view. CONCLUSIONS S2AI screws should be carefully placed to avoid anterior deviation compared with caudal deviation in terms of the safety margin, except in patients with a deep-seated L-5. The difference in safety margins between entry points A and B was negligible. Intraoperative fluoroscopy is recommended with a pelvic inlet view tilted 60 degrees-70 degrees from the S-1 slope to avoid anterior screw deviation. The lateral view is recommended to confirm that the screw is not deviated caudally.
引用
收藏
页码:536 / 542
页数:7
相关论文
共 18 条
[1]   Low Profile Pelvic Fixation Anatomic Parameters for Sacral Alar-Iliac Fixation Versus Traditional Iliac Fixation [J].
Chang, Tai-Li ;
Sponseller, Paul D. ;
Kebaish, Khaled M. ;
Fishman, Elliot K. .
SPINE, 2009, 34 (05) :436-440
[2]   Pelvic Fixation in Adult and Pediatric Spine Surgery: Historical Perspective, Indications, and Techniques AAOS Exhibit Selection [J].
Jain, Amit ;
Hassanzadeh, Hamid ;
Strike, Sophia A. ;
Menga, Emmanuel N. ;
Sponseller, Paul D. ;
Kebaish, Khaled M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (18) :1521-1528
[3]   A novel approach to navigated implantation of S-2 alar iliac screws using inertial measurement units [J].
Jost, Gregory F. ;
Walti, Jonas ;
Mariani, Luigi ;
Cattin, Philippe .
JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (03) :447-453
[4]   Pseudarthrosis in long adult spinal deformity instrumentation and fusion to the sacrum: Prevalence and risk factor analysis of 144 cases [J].
Kim, Yongjung J. ;
Bridwell, Keith H. ;
Lenke, Lawrence G. ;
Rhim, Seungchul ;
Cheh, Gene .
SPINE, 2006, 31 (20) :2329-2336
[5]   A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis [J].
Kwan, Mun Keong ;
Jeffry, Amit ;
Chan, Chris Yin Wei ;
Saw, Lim Beng .
SURGICAL AND RADIOLOGIC ANATOMY, 2012, 34 (03) :217-227
[6]   Trajectory of Transsacral Iliac Screw for Lumbopelvic Fixation A 3-Dimensional Computed Tomography Study [J].
Lee, Sang-Hun ;
Jin, Wook ;
Kim, Ki-Tack ;
Suk, Kyung-Soo ;
Lee, Jung-Hee ;
Seo, Geon-Wook .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (03) :151-156
[7]   Sacropelvic Fixation Two Case Reports of a New Percutaneous Technique [J].
Martin, Christopher T. ;
Witham, Timothy F. ;
Kebaish, Khaled M. .
SPINE, 2011, 36 (09) :E618-E621
[8]   Combined S-1 and S-2 sacral alar-iliac screws as a salvage technique for pelvic fixation after pseudarthrosis and lumbosacropelvic instability [J].
Mattei, Tobias A. ;
Fassett, Daniel R. .
JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (03) :321-330
[9]   An S-2 alar iliac pelvic fixation Technical note [J].
Matteini, Lauren E. ;
Kebaish, Khaled M. ;
Volk, W. Robert ;
Bergin, Patrick F. ;
Yu, Warren D. ;
O'Brien, Joseph R. .
NEUROSURGICAL FOCUS, 2010, 28 (03) :1-4
[10]   Unplanned reoperation after lumbopelvic fixation with S-2 alar-iliac screws or iliac bolts [J].
Mazur, Marcus D. ;
Ravindra, Vijay M. ;
Schmidt, Meic H. ;
Brodke, Darrel S. ;
Lawrence, Brandon D. ;
Riva-Cambrin, Jay ;
Dailey, Andrew T. .
JOURNAL OF NEUROSURGERY-SPINE, 2015, 23 (01) :67-76