Clinical implications of fetal magnetocardiography

被引:37
|
作者
Quartero, HWP
Stinstra, JG
Golbach, EGM
Meijboom, EJ
Peters, MJ
机构
[1] Med Spectrum Twente, Dept Obstet & Gynecol, NL-7500 KA Enschede, Netherlands
[2] Univ Twente, Inst Biomed Technol, Fac Appl Phys, NL-7500 AE Enschede, Netherlands
[3] Univ Utrecht, Med Ctr, Pediat Cardiac Ctr, Utrecht, Netherlands
[4] Univ Utrecht, Med Ctr, Dept Obstet & Gynecol, Utrecht, Netherlands
关键词
congenital heart defect; fetal arrhythmia; fetal magnetocardiography; M-mode ultrasound;
D O I
10.1046/j.1469-0705.2002.00754.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To test the usefulness and reliability of fetal magnetocardiography as a diagnostic or screening tool, both for fetuses with arrhythmias as well as for fetuses with a congenital heart defect. Methods We describe 21 women with either a fetal arrhythmia or a congenital heart defect discovered during prenatal evaluation by sonography. Four fetuses showed a complete atrioventricular block, two an atrial flutter, nine ventricular extrasystole, and one a complete irregular heart rate. Five fetuses were suspected to have a congenital heart defect. In all cases magnetocardiograms were recorded. Results Nine fetuses with extrasystole showed a range of premature atrial contractions, premature junctional beats or premature ventricular contractions. Two fetuses with atrial flutter showed typical flutter waves and four fetuses with complete atrioventricular block showed an uncoupling of P-wave and QRS complex. One fetus showed a pattern suggestive of a bundle branch block. In three of four fetuses with confirmed congenital heart defects the magnetocardiogram showed abnormalities. Conclusion Fetal magnetocardiography allows an insight into the electrophysiological aspects of the fetal heart, is accurate in the classification of fetal arrhythmias, and shows potential as a tool in defining a population at risk for congenital heart defects.
引用
收藏
页码:142 / 153
页数:12
相关论文
共 50 条
  • [1] Fetal magnetocardiography: clinical relevance and feasibility
    ter Brake, HJM
    Rijpma, AP
    Stinstra, JG
    Borgmann, J
    Holland, HJ
    Krooshoop, HJG
    Peters, MJ
    Flokstra, J
    Quartero, HWP
    Rogalla, H
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 368 (1-4): : 10 - 17
  • [2] Vector fetal magnetocardiography
    Rassi, D
    Zhuravlev, Y
    Lewis, MJ
    Emery, SJ
    BIOMAG 96: PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON BIOMAGNETISM, VOLS I & II, 2000, : 533 - 536
  • [3] Magnetocardiography for fetal arrhythmias
    Strasburger, Janette F.
    Cheulkar, Bageshree
    Wakai, Ronad T.
    HEART RHYTHM, 2008, 5 (07) : 1073 - 1076
  • [4] Magnetocardiography in the diagnosis of fetal arrhythmia
    van Leeuwen, P
    Hailer, B
    Bader, W
    Geissler, J
    Trowitzsch, E
    Grönemeyer, DHW
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1999, 106 (11): : 1200 - 1208
  • [5] Combined fetal ultrasonography and magnetocardiography
    Wakai, Ronald T.
    Zhao, Hui
    Strasburger, Janette
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5585 - 5586
  • [6] Magnetocardiography in the diagnosis of fetal arrhythmias
    Van Hare, George F.
    HEART RHYTHM, 2013, 10 (08) : 1199 - 1200
  • [7] Monitoring fetal development with magnetocardiography
    Padhye, NS
    Brazdeikis, A
    Verklan, MT
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3609 - 3610
  • [8] Assessment of fetal neurodevelopment via fetal magnetocardiography
    Wakai, RT
    EXPERIMENTAL NEUROLOGY, 2004, 190 : S65 - S71
  • [9] Magnetocardiography in the detection of fetal arrhythmias
    Golbach, EG
    Stinstra, JG
    Petrs, MJ
    Quartero, RH
    Klumper, FJ
    Meiiboom, EJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 415A - 415A
  • [10] Fetal magnetocardiography in twin pregnancy
    Van Leeuwen, P
    Schüssler, M
    BIOMAG 96: PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON BIOMAGNETISM, VOLS I & II, 2000, : 585 - 588