Two-stage electrostatic precipitators for the reduction of PM2.5 particle emission

被引:174
作者
Jaworek, A. [1 ]
Marchewicz, A. [1 ]
Sobczyk, A. T. [1 ]
Krupa, A. [1 ]
Czech, T. [1 ]
机构
[1] Polish Acad Sci, Inst Fluid Flow Machinery, Fiszera 14, PL-80231 Gdansk, Poland
关键词
Electrostatic precipitation; Electrostatic agglomeration; Two-stage electrostatic precipitator; Precharger; PM2.5; particles; Collection efficiency; FLY-ASH PARTICLES; CHARGED AEROSOL AGGLOMERATION; ALTERNATING ELECTRIC-FIELD; PARTICULATE MATTER DPM; SOLID-GAS SEPARATION; VOLTAGE WAVE-FORMS; SUBMICRON PARTICLES; FINE PARTICLES; COLLECTION EFFICIENCY; ULTRAFINE PARTICLES;
D O I
10.1016/j.pecs.2018.03.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
Electrostatic precipitator is the most efficient device used for the removal of fly ash particles from the flue gases produced by coal-fired boilers in power plants. However, the fractional collection efficiency of electrostatic precipitators steeply decreases for particles smaller than 1 mu m, and particles in the size range of 200-500 nm are removed with lower collection efficiency than those outside this range. These particles are dangerous to humans and have detrimental environmental effects, so there is a need for novel more efficient technologies for their control. One of the answers to this challenge is the two-stage electrostatic precipitator, in which the electrostatic charging and precipitation processes have been separated. The PM2.5 particles (of a size < 2.5 mu m) are electrically charged in a separate device (precharger) to a maximal possible electric charge, and then precipitated in a parallel plate collector, free of corona discharge. The electric field in the collection stage can be higher than in an electrostatic precipitator due to the lack of sharp discharge points. A higher electric field allows an increase of the collection efficiency for PM2.5 particles. Another solution is the agglomeration of submicron particles to form larger particles before their precipitation by a parallel-plate collector, conventional electrostatic precipitator or any other gas cleaning device. In some of the reviewed devices, both of these processes were combined in a single device that allowed further increases in the collection efficiency for submicron particles. Devices of this type have been tested in a labor semi-industrial scale for the removal of PM2.5 particles from flue gases or diesel engine exhausts. In this paper, various constructions of two-stage electrostatic precipitators, comprising a precharger and/or agglomerator in the first stage, and an electrostatic collector in the second stage, have been reviewed. Some of these devices were able to increase the mass collection efficiency above 95% for PM2.5 particles. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:206 / 233
页数:28
相关论文
共 335 条
[91]   A technical assessment of a particle hybrid collector in a pilot plant [J].
Gutierrez Ortiz, F. J. ;
Navarrete, B. ;
Canadas, L. ;
Salvador, L. .
CHEMICAL ENGINEERING JOURNAL, 2007, 127 (1-3) :131-142
[92]   Enhancement of diesel particulate matter collection in an electrostatic water-spraying scrubber [J].
Ha, Tran Hong ;
Nishida, Osami ;
Fujita, Hirotsugu ;
Wataru, Harano .
JOURNAL OF MARINE SCIENCE AND TECHNOLOGY, 2010, 15 (03) :271-279
[93]   Efficacy of climate forcings [J].
Hansen, J ;
Sato, M ;
Ruedy, R ;
Nazarenko, L ;
Lacis, A ;
Schmidt, GA ;
Russell, G ;
Aleinov, I ;
Bauer, M ;
Bauer, S ;
Bell, N ;
Cairns, B ;
Canuto, V ;
Chandler, M ;
Cheng, Y ;
Del Genio, A ;
Faluvegi, G ;
Fleming, E ;
Friend, A ;
Hall, T ;
Jackman, C ;
Kelley, M ;
Kiang, N ;
Koch, D ;
Lean, J ;
Lerner, J ;
Lo, K ;
Menon, S ;
Miller, R ;
Minnis, P ;
Novakov, T ;
Oinas, V ;
Perlwitz, J ;
Perlwitz, J ;
Rind, D ;
Romanou, A ;
Shindell, D ;
Stone, P ;
Sun, S ;
Tausnev, N ;
Thresher, D ;
Wielicki, B ;
Wong, T ;
Yao, M ;
Zhang, S .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2005, 110 (D18) :1-45
[94]   CALCULATION OF ELECTRIC-FIELD STRENGTH DISTRIBUTIONS FOR NEW ELECTROSTATIC PRECIPITATOR DISCHARGE ELECTRODE DESIGNS [J].
HAO, JM ;
HE, KB ;
CHAO, HX .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1990, 40 (11) :1510-1513
[95]  
Harrison W, 2004, P 9 INT C EL PREC KR, P9
[96]   ELECTRICAL AGGLOMERATION OF AEROSOL-PARTICLES IN AN ALTERNATING ELECTRIC-FIELD [J].
HAUTANEN, J ;
KILPELAINEN, M ;
KAUPPINEN, EI ;
JOKINIEMI, J ;
LEHTINEN, K .
AEROSOL SCIENCE AND TECHNOLOGY, 1995, 22 (02) :181-189
[97]   OPTIMIZATION OF FILTRATION EFFICIENCY AND OZONE PRODUCTION OF THE ELECTROSTATIC PRECIPITATOR [J].
HAUTANEN, J ;
JANKA, K ;
KESKINEN, J ;
LEHTIMAKI, M ;
KIVISTO, T .
JOURNAL OF AEROSOL SCIENCE, 1986, 17 (03) :622-626
[98]  
Hautanen J, 1992, J AEROSOL SCI S1, V23, pS783
[99]   Electrostatic Charging and Precipitation of Diesel Soot [J].
Hayashi, Hideaki ;
Takasaki, Yasuhiro ;
Kawahara, Kazuki ;
Takashima, Kazunori ;
Mizuno, Akira .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (01) :331-335
[100]   A REVIEW OF ELECTROSTATICALLY AUGMENTED GAS CLEANING DEVICES FOR PARTICULATE REMOVAL [J].
HENRY, RF ;
PODOLSKI, WF ;
SAXENA, SC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (04) :939-949