Current clinical methods of measurement of respiratory rate give imprecise values

被引:38
作者
Drummond, Gordon B. [1 ]
Fischer, Darius [2 ]
Arvind, D. K. [2 ]
机构
[1] Univ Edinburgh, Dept Anaesthesia Crit Care & Pain Med, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Ctr Speckled Comp, Sch Informat, Edinburgh, Midlothian, Scotland
基金
英国工程与自然科学研究理事会;
关键词
DETECTING DETERIORATION; RELIABILITY; MORTALITY;
D O I
10.1183/23120541.00023-2020
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Respiratory rate is a basic clinical measurement used for illness assessment. Errors in measuring respiratory rate are attributed to observer and equipment problems. Previous studies commonly report rate differences ranging from 2 to 6 breaths.min(-1) between observers. Methods: To study why repeated observations should vary so much, we conducted a virtual experiment, using continuous recordings of breathing from acutely ill patients. These records allowed each breathing cycle to be precisely timed. We made repeated random measures of respiratory rate using different sample durations of 30, 60 and 120 s. We express the variation in these repeated rate measurements for the different sample durations as the interquartile range of the values obtained for each subject. We predicted what values would be found if a single measure, taken from any patient, were repeated and inspected boundary values of 12, 20 or 25 breaths.min(-1), used by the UK National Early Warning Score, for possible mis-scoring. Results: When the sample duration was nominally 30 s, the mean interquartile range of repeated estimates was 3.4 breaths.min(-1). For the 60 s samples, the mean interquartile range was 3 breaths.min(-1), and for the 120 s samples it was 2.5 breaths.min(-1). Thus, repeat clinical counts of respiratory rate often differ by >3 breaths.min(-1). For 30 s samples, up to 40% of National Early Warning Scores could be misclassified. Conclusions: Early warning scores will be unreliable when short sample durations are used to measure respiratory rate. Precision improves with longer sample duration, but this may be impractical unless better measurement methods are used.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 32 条
[1]   Is everyone really breathing 20 times a minute? Assessing epidemiology and variation in recorded respiratory rate in hospitalised adults [J].
Badawy, Jack ;
Oanh Kieu Nguyen ;
Clark, Christopher ;
Halm, Ethan A. ;
Makam, Anil N. .
BMJ QUALITY & SAFETY, 2017, 26 (10) :832-836
[2]   Decision-tree early warning score (DTEWS) validates the design of the National Early Warning Score (NEWS) [J].
Badriyah, Tessy ;
Briggs, James S. ;
Meredith, Paul ;
Jarvis, Stuart W. ;
Schmidt, Paul E. ;
Featherstone, Peter I. ;
Prytherch, David R. ;
Smith, Gary B. .
RESUSCITATION, 2014, 85 (03) :418-423
[3]   Revitalizing a Vital Sign: Improving Detection of Tachypnea at Primary Triage [J].
Bianchi, William ;
Dugas, Andrea Freyer ;
Hsieh, Yu-Hsiang ;
Saheed, Mustapha ;
Hill, Peter ;
Lindauer, Cathleen ;
Terzis, Andreas ;
Rothman, Richard E. .
ANNALS OF EMERGENCY MEDICINE, 2013, 61 (01) :37-43
[4]   The relation of anoxemia to the type of breathing in pneumonia - A study of respiration by means of a body plethysmograph [J].
Binger, CAL ;
Davis, JS .
JOURNAL OF CLINICAL INVESTIGATION, 1928, 6 (02) :171-185
[5]   Measurement error is often neglected in medical literature: a systematic review [J].
Brakenhoff, Timo B. ;
Mitroiu, Marian ;
Keogh, Ruth H. ;
Moons, Karel G. M. ;
Groenwold, Rolf H. H. ;
van Smeden, Maarten .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2018, 98 :89-97
[6]  
Brekke IJ., 2019, PLOS ONE, V14, P1
[7]   Vital Signs Monitoring with Wearable Sensors in High-risk Surgical Patients A Clinical Validation Study [J].
Breteler, Martine J. M. ;
KleinJan, Eline J. ;
Dohmen, Daan A. J. ;
Leenen, Luke P. H. ;
van Hillegersberg, Richard ;
Ruurda, Jelle P. ;
van Loon, Kim ;
Blokhuis, Taco J. ;
Kalkman, Cor J. .
ANESTHESIOLOGY, 2020, 132 (03) :424-439
[8]   Association between clinically abnormal observations and subsequent in-hospital mortality: a prospective study [J].
Buist, M ;
Bernard, S ;
Nguyen, TV ;
Moore, G ;
Anderson, J .
RESUSCITATION, 2004, 62 (02) :137-141
[9]   Effectiveness of continuous or intermittent vital signs monitoring in preventing adverse events on general wards: a systematic review and meta-analysis [J].
Cardona-Morrell, M. ;
Prgomet, M. ;
Turner, R. M. ;
Nicholson, M. ;
Hillman, K. .
INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (10) :806-824
[10]   The value of vital sign trends for detecting clinical deterioration on the wards [J].
Churpek, Matthew M. ;
Adhikari, Richa ;
Edelson, Dana P. .
RESUSCITATION, 2016, 102 :1-5