Experimental investigation and performance of timber-concrete composite floor structure with non-metallic connection system

被引:24
作者
Dankova, J. [1 ]
Mec, P. [1 ]
Safrata, J. [1 ]
机构
[1] VSB Tech Univ Ostrava, Fac Civil Engn, Dept Bldg Mat & Diagnost Struct, Ludvika Podeste 1875-17, Ostrava 70833, Czech Republic
关键词
Composite; Timber-concrete; Board; Plywood; Gluing; Full-scale bending tests; Shear test; BEHAVIOR;
D O I
10.1016/j.engstruct.2019.05.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents results of an experimental study implemented with the goal to verify performance of an innovative type of a timber-concrete composite floor structure. It is unique because the connections of both parts of the composite T-cross-section are assembled from non-metallic materials only. The connection element is a glued board made of plywood. Experimentally, by a shear test, values of secant slip modulus were determined at 12 samples in total. Results of shear tests were analysed by exploratory statistical methods. This method of connection has a medium level of rigidity when loaded with shear force and compared to other types of connection. However, at the same time it manifests a significant area of plastic deformations at higher levels of load. Part tests were carried out with 3 samples, each of which was subject to various levels of environmental effects and a load time before the test. Results were compared with results of the test performed with a reference sample - a non-composite structure of identical dimensions. Experimental data were compared with data provided by the theoretical design model as stated in Eurocodes. The comparison relates to short-term behaviour of the structure. This article also includes consideration of a comparison with the performance of the HBV (R) System type structure. With the part span of 6.5 m, the final maximum short-term resistance of the timber-concrete composite structure was approximately 200 kN and the maximum average mid-span deflection was approximately 54 mm. For a structure exposed for the period of 12 months to an outdoor environment with the load action for 166 days with the intensity of 10 kN/m(2), the final short-term resistance of the timber-concrete composite structure was higher by 21% than that of a non-composite structure of identical dimensions.
引用
收藏
页码:207 / 218
页数:12
相关论文
共 43 条
  • [21] The effect of ductile connectors on the behaviour of timber-concrete composite beams
    Dias, Alfredo M. P. G.
    Jorge, Luis F. C.
    [J]. ENGINEERING STRUCTURES, 2011, 33 (11) : 3033 - 3042
  • [22] Fontana M., 2000, 6 INT S FIRE SAF SCI, P891, DOI [10.3801/IAFSS.FSS.6-891, DOI 10.3801/IAFSS.FSS.6-891]
  • [23] Frangi A, 2001, IABSE, V8, P35
  • [24] Fire Design of Timber-Concrete Composite Slabs with Screwed Connections
    Frangi, Andrea
    Knobloch, Markus
    Fontana, Mario
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (02) : 219 - 228
  • [25] Exact static analysis of partially composite beams and beam-columns
    Girhammar, Ulf Arne
    Pan, Dan H.
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2007, 49 (02) : 239 - 255
  • [26] A simplified analysis method for composite beams with interlayer slip
    Girhammar, Ulf Arne
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2009, 51 (07) : 515 - 530
  • [27] Gurksnys K., 2005, Journal of Civil Engineering and Management, V11, P277, DOI 10.1080/13923730.2005.9636358
  • [28] Laboratory tests of composite wood-concrete beams
    Gutkowski, R.
    Brown, K.
    Shigidi, A.
    Natterer, J.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (06) : 1059 - 1066
  • [29] James O., 2009, NZL TIM DES J, V19, P4
  • [30] Kuklik P, 2012, WORLD C TIMB ENG 201