Experimental investigation and performance of timber-concrete composite floor structure with non-metallic connection system

被引:24
作者
Dankova, J. [1 ]
Mec, P. [1 ]
Safrata, J. [1 ]
机构
[1] VSB Tech Univ Ostrava, Fac Civil Engn, Dept Bldg Mat & Diagnost Struct, Ludvika Podeste 1875-17, Ostrava 70833, Czech Republic
关键词
Composite; Timber-concrete; Board; Plywood; Gluing; Full-scale bending tests; Shear test; BEHAVIOR;
D O I
10.1016/j.engstruct.2019.05.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents results of an experimental study implemented with the goal to verify performance of an innovative type of a timber-concrete composite floor structure. It is unique because the connections of both parts of the composite T-cross-section are assembled from non-metallic materials only. The connection element is a glued board made of plywood. Experimentally, by a shear test, values of secant slip modulus were determined at 12 samples in total. Results of shear tests were analysed by exploratory statistical methods. This method of connection has a medium level of rigidity when loaded with shear force and compared to other types of connection. However, at the same time it manifests a significant area of plastic deformations at higher levels of load. Part tests were carried out with 3 samples, each of which was subject to various levels of environmental effects and a load time before the test. Results were compared with results of the test performed with a reference sample - a non-composite structure of identical dimensions. Experimental data were compared with data provided by the theoretical design model as stated in Eurocodes. The comparison relates to short-term behaviour of the structure. This article also includes consideration of a comparison with the performance of the HBV (R) System type structure. With the part span of 6.5 m, the final maximum short-term resistance of the timber-concrete composite structure was approximately 200 kN and the maximum average mid-span deflection was approximately 54 mm. For a structure exposed for the period of 12 months to an outdoor environment with the load action for 166 days with the intensity of 10 kN/m(2), the final short-term resistance of the timber-concrete composite structure was higher by 21% than that of a non-composite structure of identical dimensions.
引用
收藏
页码:207 / 218
页数:12
相关论文
共 43 条
  • [1] Abd Ghafar H, 2008, 10 WORLD C TIMB ENG
  • [2] [Anonymous], 1993, 380 CEN EN
  • [3] [Anonymous], 2009, THESIS
  • [4] [Anonymous], 1991, 26891 CEN EN
  • [5] [Anonymous], 2006, 2 EUR CEN 1
  • [6] [Anonymous], 2004, 5 EUR CEN 1
  • [7] Basaglia B, 2015, P 2 INT C PERF BAS L
  • [8] Bathon L, 2000, 6 WORLD C TIMB ENG W, P2000
  • [9] Bathon LA, 2006, 9 WORLD C TIMB ENG W
  • [10] Bathon T, U. S. Patent No, Patent No. [8,245,47, 824547]