Proper management of pericardial tamponade as a late complication of implantable cardiac device placement

被引:37
作者
Polin, Glenn M. [1 ]
Zado, Erica [1 ]
Nayak, Hernal [1 ]
Cooper, Joshua M. [1 ]
Russo, Andrea M. [1 ]
Dixit, Sanjay [1 ]
Lin, David [1 ]
Marchlinski, Francis E. [1 ]
Verdino, Ralph J. [1 ]
机构
[1] Univ Penn, Hlth Syst, Div Cardiol, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/j.amjcard.2006.01.078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac tamponade as a late complication of device placement is exceedingly rare, with only several case reports previously published. We sought to characterize our institution's experience with cardiac tamponade occurring > 30 days after permanent pacemaker or implantable cardioverter-defibrillator placement. From January 2000 to June 2003, 2,535 patients received an implantable cardiac device at our institution. Four patients (0.17%) presented with cardiac tamponade >30 days after the procedure. A fifth patient who had undergone implantation at another institution but was referred to our group with tamponade was also included in the analysis. The baseline characteristics varied widely with respect to age, gender, device type, and anticoagulation status. Lead parameters were altered in 2 of 5 patients. Two patients were treated with pericardiocentesis, I patient had pericardiocentesis followed by lead extraction, and 2 patients required cardiac surgical intervention. Pericardial fluid culture and cytologic findings were negative in all patients. All patients had normal recovery and were well at a mean follow-up of 31 months. In conclusion, cardiac tamponade is a rare, but serious late complication of permanent pacemaker and implantable cardioverter-defibrillator placement. The patient characteristics and mode of presentation vary widely. Once tamponade is recognized and treated, these patients appear well at long-term follow-up, with no other device-related problems. A role for lead manipulation does not appear to exist in the standard treatment of these patients. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:223 / 225
页数:3
相关论文
共 15 条
[1]   Oozing from the pericardium as an etiology of cardiac tamponade associated with screw-in atrial leads [J].
Aizawa, K ;
Kaneko, Y ;
Yamagishi, T ;
Utsugi, T ;
Suzuki, T ;
Ishikawa, S ;
Otaki, A ;
Morishita, Y ;
Hasegawa, A ;
Kurabayashi, M ;
Nagai, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (03) :381-383
[2]   Delayed myocardial perforation following pacemaker implantation [J].
Alvarez, VB ;
Tamargo, JAA ;
Aguado, MG ;
Fernández, MM ;
Morales, C .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 93 (01) :89-91
[3]   Delayed complications following pacemaker implantation [J].
Ellenbogen, KA ;
Wood, MA ;
Shepard, RK .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (08) :1155-1158
[4]   Delayed cardiac tamponade after pacemaker insertion [J].
Gershon, T ;
Kuruppu, J ;
Olshaker, J .
JOURNAL OF EMERGENCY MEDICINE, 2000, 18 (03) :355-359
[5]   Pacemaker and implantable cardioverter defibrillator implantation without reversal of warfarin therapy [J].
Giudici, MC ;
Barold, SS ;
Paul, DL ;
Bontu, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (03) :358-360
[6]   Late complications following permanent pacemaker implantation or elective unit replacement [J].
Harcombe, AA ;
Newell, SA ;
Ludman, PF ;
Wistow, TE ;
Sharples, LD ;
Schofield, PM ;
Stone, DL ;
Shapiro, LM ;
Cole, T ;
Petch, MC .
HEART, 1998, 80 (03) :240-244
[7]   Delayed lead perforation: A disturbing trend [J].
Khan, MN ;
Joseph, G ;
Khaykin, Y ;
Ziada, KM ;
Wilkoff, BL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (03) :251-253
[8]   Complications related to permanent pacemaker therapy [J].
Kiviniemi, MS ;
Pirnes, MA ;
Eränen, HJK ;
Kettunen, RVJ ;
Hartikainen, JEK .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (05) :711-720
[9]   Postpericardiotomy syndrome and cardiac tamponade following transvenous pacemaker placement [J].
Miller, GL ;
Coccio, EB ;
Sharma, SC .
CLINICAL CARDIOLOGY, 1996, 19 (03) :255-256
[10]   Anesthetic management of cardiac tamponade after dual-chamber implantable cardioverter defibrillator implantation in a patient with dilated cardiomyopathy [J].
Sato, Y ;
Horiguchi, T ;
Nishikawa, T .
JOURNAL OF CLINICAL ANESTHESIA, 2004, 16 (07) :554-556