Processing gain and noise in multi-electrode impedance cytometers: Comprehensive electrical design methodology and characterization

被引:20
|
作者
Xie, Pengfei [1 ]
Cao, Xinnan [1 ]
Lin, Zhongtian [1 ]
Talukder, Niloy [1 ]
Emaminejad, Sam [2 ]
Javanmard, Mehdi [1 ]
机构
[1] Rutgers State Univ, Elect & Comp Engn Dept, Piscataway, NJ 08854 USA
[2] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90024 USA
关键词
Electrical impedance sensing; Microfluidics; Impedance cytometery; Signal to noise ratio; Interdigitated electrodes; Label-free sensing; FLOW-CYTOMETRY; CELLS;
D O I
10.1016/j.snb.2016.09.182
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We introduce a novel technique for minimizing false positives and improving the fidelity of signals detected with impedance cytometry. We make use of interdigitated multi-finger electrodes for introducing redundancy and robustness in impedance based detection of micro-and nanoparticles. Multi electrode impedance sensors provide multiple peaks and unique signatures for single cells and particles, and can be used in conjunction with match filters to provide processing gain. This approach is particularly useful in minimizing false positives, which is particularly difficult for signals with low signal-to-noise ratio. The unique signature provided by multi-electrode sensors results in higher signal-power compared to single electrode pair sensors, and can also result in more fidelity in distinguishing particles from noise. This technique holds the potential of using micro-scale channels for detection of nanoscale particles such as viruses and even individual proteins. Previous work has shown extraction of signal from noise using multi-electrode sensors. To the best of our knowledge, this manuscript presents the first comprehensive attempt to characterize processing gain improvement and system noise in multi-electrode sensors by directly comparing simultaneous measurements obtained from sensors fabricated along the same channel. By measuring simultaneously the electrode pairs along a single channel, consistency in flow rate and buffer conditions is ensured, while other experimental assay-to-assay variations are minimized. We achieve high SNR for particles as small as 1 urn in a 30 m wide by 10 diameter tall pore. SNR and noise measurements for different electrode configurations and excitation frequencies is thoroughly studied. The results of this study demonstrated that while increasing number of electrodes resulted in increased processing gain, noise levels also increased with larger number of electrode fingers, thus total SNR remained relatively unchanged. Our investigations showed that this increase in noise is likely due to electrochemical reactions at the surface of the electrode dominating the total noise. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:672 / 680
页数:9
相关论文
共 14 条
  • [1] Field analysis and electrical models of multi-electrode impedance sensors
    Szczepanik, Zdzislaw
    Rucki, Zbigniew
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 133 (01) : 13 - 22
  • [2] Characterization of a Proposed Quarry Site using Multi-Electrode Electrical Resistivity Tomography
    Kayode, John Stephen
    Arifin, Mohd Hariri
    Nawawi, Mohd
    SAINS MALAYSIANA, 2019, 48 (05): : 945 - 963
  • [3] Design and validation of a multi-electrode bioimpedance system for enhancing spatial resolution of cellular impedance studies
    Alexander, Frank A., Jr.
    Celestin, Michael
    Price, Dorielle T.
    Nanjundan, Meera
    Bhansali, Shekhar
    ANALYST, 2013, 138 (13) : 3728 - 3734
  • [4] Design and Electrical Analysis of Multi-Electrode Cylindrical Dielectric Barrier Discharge Plasma Reactor
    Niu, Guanghui
    Guo, Guangmeng
    Tang, Jie
    Li, Yanping
    Wang, Xu
    Duan, Yixiang
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2019, 47 (01) : 419 - 426
  • [5] High-Density Electrical Recording and Impedance Imaging With a Multi-Modal CMOS Multi-Electrode Array Chip
    Miccoli, Beatrice
    Lopez, Carolina Mora
    Goikoetxea, Erkuden
    Putzeys, Jan
    Sekeri, Makrina
    Krylychkina, Olga
    Chang, Shuo-Wen
    Firrincieli, Andrea
    Andrei, Alexandru
    Reumers, Veerle
    Braeken, Dries
    FRONTIERS IN NEUROSCIENCE, 2019, 13
  • [6] Electrical impedance imaging of human muscle at the microscopic scale using a multi-electrode needle device: A simulation study
    Rutkove, Seward B.
    Kwona, Hyeuknam
    Guasch, Maria
    Wu, Jim S.
    Sanchez, Benjamin
    CLINICAL NEUROPHYSIOLOGY, 2018, 129 (08) : 1704 - 1708
  • [7] A new algorithm for processing data of the improved multi-electrode electrical exploration method: application to groundwater investigation
    Vu, Minh Duc
    Do, Chung Anh
    Pham, Luan Thanh
    Eldosouky, Ahmed M.
    Gomez-Ortiz, David
    Othman, Abdullah
    ACTA GEOPHYSICA, 2024, 72 (04) : 2555 - 2563
  • [8] Bayesian inverse methods for spatiotemporal characterization of gastric electrical activity from cutaneous multi-electrode recordings
    Allegra, Alexis B.
    Gharibans, Armen A.
    Schamberg, Gabriel E.
    Kunkel, David C.
    Coleman, Todd P.
    PLOS ONE, 2019, 14 (10):
  • [9] An electrical impedance tomography (EIT) multi-electrode needle-probe device for local assessment of heterogeneous tissue impeditivity
    Meroni, Davide
    Maglioli, Camilla Carpano
    Bovio, Dario
    Greco, Francesco G.
    Aliverti, Andrea
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1385 - 1388
  • [10] The electrical characterization of a multi-electrode odor detection sensor array based on the single SnO2 nanowire
    Sysoev, V. V.
    Strelcov, E.
    Kar, S.
    Kolmakov, A.
    THIN SOLID FILMS, 2011, 520 (03) : 898 - 903