Multicomponent analyses of chiral samples by use of regression analysis of UV-visible spectra of cyclodextrin guest-host complexes

被引:13
作者
Fakayode, Sayo O. [1 ]
Brady, Pamlea N. [1 ]
Pollard, David A. [1 ]
Mohammed, Abdul K. [1 ]
Warner, Isiah M. [2 ]
机构
[1] Winston Salem State Univ, Dept Chem, Winston Salem, NC 27110 USA
[2] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
关键词
UV-visible spectroscopy; Guest-host complexes; Partial-least-square regression; Multicomponent chiral analytes; Chiral analysis; INDICATOR-DISPLACEMENT ASSAYS; ALPHA-AMINO-ACIDS; ENANTIOMERIC COMPOSITION; CHEMOMETRIC ANALYSIS; PHARMACEUTICAL INTEREST; IONIC LIQUID; RECOGNITION; MOLECULES; DISCRIMINATION; CHROMATOGRAPHY;
D O I
10.1007/s00216-009-2853-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the first combined use of analytical spectroscopy, guest-host chemistry, and multivariate regression analysis for determination of enantiometric composition of multicomponent samples of chiral analytes. Sample solutions containing multicomponent analytes of ephedrine, tryptophan, propranolol, and proline of varying enantiomeric composition with beta-cyclodextrin (BCD) or methyl-beta-cyclodextrin (Me-BCD) as chiral host molecules were investigated using ultraviolet (UV)-visible spectroscopy. The interactions of enantiomers of chiral analytes with chiral hosts resulted in the formation of transient diastereomeric inclusion complexes with varying spectral properties. Multivariate analysis using partial-least-square (PLS) regression was used to correlate subtle changes in the UV-visible spectra of the guest-host complexes with the enantiomeric composition of the calibration samples. These PLS regressions were carefully optimized and then used to predict the enantiomeric composition of multicomponent chiral analytes of validation samples. The results of these validation studies demonstrate the predictive ability of the regression models for determination of future enantiomeric composition of samples. The accuracy of the models to correctly predict the enantiomeric composition of samples, evaluated by use of the root mean square percent relative error (RMS%RE) was analyte and chiral host dependent. In general, better prediction of enantiomeric composition of samples and low RMS%RE values were obtained when Me-BCD was used as the chiral host. The analyses procedure reported here is simple, rapid, and inexpensive. In addition, this approach does not require prior separation of chiral analytes, thus reducing analysis time and eliminating the need for expensive chiral columns.
引用
收藏
页码:1645 / 1653
页数:9
相关论文
共 40 条
[1]  
Adams M.J., 1995, CHEMOMETRICS ANAL SP
[2]  
ARMSTRONG DW, 1988, CRIT REV ANAL CHEM, V19, P175
[3]   Raman optical activity: An incisive probe of chirality, and of biomolecular structure and behaviour [J].
Barron, Laurence D. ;
Zhu, Fujiang ;
Hecht, Lutz .
VIBRATIONAL SPECTROSCOPY, 2006, 42 (01) :15-24
[4]  
Berova N., 2000, Circular Dichroism: Principles and Applications
[5]   Determination of the enantiomeric composition of some molecules of pharmaceutical interest by chemometric analysis of the UV spectra of cyclodextrin guest-host complexes [J].
Busch, KW ;
Swamidoss, IM ;
Fakayode, SO ;
Busch, MA .
ANALYTICA CHIMICA ACTA, 2004, 525 (01) :53-62
[6]   Determination of the enantiomeric composition of guest molecules by chemometric analysis of the UV-visible spectra of cyclodextrin guest-host complexes [J].
Busch, KW ;
Swamidoss, IM ;
Fakayode, SO ;
Busch, MA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (07) :1690-1691
[7]   Stationary phase with specific surface properties for the separation of estradiol diastereoisomers [J].
Buszewski, B ;
Jezierska-Switala, M ;
Kowalska, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02) :279-286
[8]   Importance of stereospecific bioanalytical monitoring in drug development [J].
Caldwell, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (01) :3-13
[9]   Chiral anion recognition by color change utilizing thiourea, azophenol, and glucopyranosyl groups [J].
Choi, Min Ki ;
Kim, Ha Na ;
Choi, Hee Jung ;
Yoon, Juyoung ;
Hyun, Myung Ho .
TETRAHEDRON LETTERS, 2008, 49 (29-30) :4522-4525
[10]   The use of poly(sodium N-undecanoyl-L-leucylvalinate), poly(sodium N-undecanoyl-L-leucinate) and poly(sodium N-undecanoyl-L-valinate) surfactants as chiral selectors for determination of enantiomeric composition of samples by multivariate regression modeling of fluorescence spectral data [J].
Fakayode, Sayo O. ;
Williams, Alicia A. ;
Busch, Marianna A. ;
Busch, Kenneth W. ;
Warner, Isiah M. .
JOURNAL OF FLUORESCENCE, 2006, 16 (05) :659-670