Implications for Distribution Networks of High Penetration of Compact Fluorescent Lamps

被引:109
作者
Watson, Neville R. [1 ]
Scott, Tasman L. [2 ]
Hirsch, Stephen J. J. [2 ]
机构
[1] Univ Canterbury, Dept Elect & Comp Engn, Christchurch 1, New Zealand
[2] Orion NZ Ltd, Christchurch, New Zealand
关键词
Compact fluorescent lamps; harmonic distortion; harmonic analysis; HARMONICS;
D O I
10.1109/TPWRD.2009.2014036
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The desire to reduce electrical loading by using energy efficient lighting has resulted in a high level of interest in replacing conventional incandescent lamps with compact fluorescent lamps (CFL). This has resulted in the New Zealand Government, through the Electricity Commission of New Zealand, running campaigns to install five CFLs in every home by, subsidizing the cost of suitable CFLs. CFLs are however, a nonlinear load hence inject harmonics into the electrical network. The CFL use electronic ballasts and the design of these have an enormous impact on the electrical performance of the CFL. In the past, the harmonics injected into the network by CFLs has been ignored as each is very small as the typically CFL is only 20 Watts. However, if widespread adoption of CFLs occurs, the combined effect of all these small sources can be just as detrimental as one large source, and is even harder to mitigate due to their distributed nature. This paper presents the results of a study to quantify the effect widespread adoption of CFLs will have on a typical distribution network. The two aspects investigated were harmonic distortion and system losses. To enable 28 800 homes to be represented a methodology for modelling a large number of distributed loads using Norton equivalents was developed and applied. In order to assess losses, a fundamental frequency power-flow was also incorporated.
引用
收藏
页码:1521 / 1528
页数:8
相关论文
共 11 条
[1]   THE EFFECTS OF SUPPLY HARMONICS ON THE PERFORMANCE OF COMPACT FLUORESCENT LAMPS [J].
ARSENEAU, R ;
OUELLETTE, M .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (02) :473-479
[2]   A COMPREHENSIVE HARMONIC STUDY OF ELECTRONIC BALLASTS AND THEIR EFFECT ON A UTILITY 12 KV, 10 MVA FEEDER [J].
EMBRIZSANTANDER, E ;
DOMIJAN, A ;
WILLIAMS, CW .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1591-1599
[3]  
GOTHELF N, 1997, RIGHT LIGHT, V2, P77
[4]  
PILEGGI DJ, 1993, IEEE T POWER DELIVER, V8, P2038
[5]   Harmonic tensor linearisation of HVdc converters [J].
Smith, BC ;
Watson, NR ;
Wood, AR ;
Arrillaga, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) :1244-1250
[6]   EFFICIENCY OF ENERGY-SAVING LAMPS AND HARMONIC DISTORTION IN DISTRIBUTION-SYSTEMS [J].
TOPALIS, FV .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (04) :2038-2042
[7]   HARMONICS FROM COMPACT FLUORESCENT LAMPS [J].
VERDERBER, RR ;
MORSE, OC ;
ALLING, WR .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (03) :670-674
[8]  
VOKAS GA, 2001, P IEEE POWER TECH PO, V1, P10
[9]  
Watson N.R., 2006, P EEA C AUCKL NZ JUN
[10]  
WATSON NR, 1995, P IPENZ C PALM N NEW, P119