Metals, heavy metals and microorganism removal from spent filter backwash water by hybrid coagulation-UF processes

被引:22
作者
Mahdavi, Mokhtar [1 ,2 ,3 ]
Amin, Mohammad Mehdi [3 ,4 ]
Mahvi, Amir Hossein [5 ]
Pourzamani, Hamidreza [3 ,4 ]
Ebrahimi, Afshin [3 ,4 ]
机构
[1] Isfahan Univ Med Sci, Environm Res Ctr, Esfahan, Iran
[2] Isfahan Univ Med Sci, Sch Hlth, Student Res Comm, Esfahan, Iran
[3] Isfahan Univ Med Sci, Sch Hlth, Dept Environm Hlth Engn, Esfahan, Iran
[4] Isfahan Univ Med Sci, Res Inst Primordial Prevent Noncommunicable Dis, Environm Res Ctr, Esfahan, Iran
[5] Univ Tehran Med Sci, Inst Environm Res, Ctr Solid Waste Res, Tehran, Iran
来源
JOURNAL OF WATER REUSE AND DESALINATION | 2018年 / 8卷 / 02期
关键词
coagulation-UF; FeCl3; poly-aluminum ferric chloride (PAFCl); spent filter backwash water reuse; spent filter backwash water treatment; HEALTH-RISK ASSESSMENT; DRINKING-WATER; ALUMINUM SPECIATION; NORTHERN PAKISTAN; ULTRAFILTRATION; FRACTIONS; PRETREATMENT; MECHANISMS; FOULANTS; LEAD;
D O I
10.2166/wrd.2017.148
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Spent filter backwash water (SFBW) reuse has attracted particular attention, especially in countries that experience water scarcity. It can act as a permanent water source until the water treatment plant is working. In this study, the concentrations of Fe, Al, Pb, As, and Cd with total and fecal coliform (TC/FC) were investigated in raw and treated SFBW by hybrid coagulation-UF processes. The pilot plant consisted of pre-sedimentation, coagulation, flocculation, clarification, and ultrafiltration (UF) units. Poly-aluminum ferric chloride (PAFCL) and ferric chloride (FeCl3) were used as pretreatment. The results showed that, at the optimum dose of PAFCl, the average removal of TC and FC was 88 and 79% and with PAFCl-UF process, it reached 100 and 100%, respectively. For FeCl3, removal efficiency of TC and FC were 81 and 72% and by applying FeCl3-UF process, it reached 100 and 100%, respectively. In comparison with FeCl3, PAFCl showed better removal efficiency for Fe, Pb, As, and Cd, except residual Al concentration. Coagulation-UF process could treat SFBW efficiently and treated SFBW could meet the US-EPA drinking water standard. Health risk index values of Fe, AL, Pb, AS, and Cd in treated SFBW indicate no risk of exposure to the use of this water.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 31 条
[1]   A review on the applicability of integrated/hybrid membrane processes in water treatment and desalination plants [J].
Ang, Wei Lun ;
Mohammad, Abdul Wahab ;
Hilal, Nidal ;
Leo, Choe Peng .
DESALINATION, 2015, 363 :2-18
[2]  
Appel C, 2002, J ENVIRON QUAL, V31, P581, DOI 10.2134/jeq2002.0581
[3]   Aluminium speciation in relation to aluminium bioavailability, metabolism and toxicity [J].
Berthon, G .
COORDINATION CHEMISTRY REVIEWS, 2002, 228 (02) :319-341
[4]   Pilot-scale investigation of drinking water ultrafiltration membrane fouling rates using advanced data analysis techniques [J].
Chen, Fei ;
Peldszus, Sigrid ;
Peiris, Ramila H. ;
Ruhl, Aki S. ;
Mehrez, Renata ;
Jekel, Martin ;
Legge, Raymond L. ;
Huck, Peter M. .
WATER RESEARCH, 2014, 48 :508-518
[5]   Heavy metals in drinking water: Occurrences, implications, and future needs in developing countries [J].
Chowdhury, Shakhawat ;
Mazumder, M. A. Jafar ;
Al-Attas, Omar ;
Husain, Tahir .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 569 :476-488
[6]   The effectiveness of polyaluminum ferric chloride (PAFCl) for turbidity and color removal from Isfahan raw water [J].
Ebrahimi, Afshin ;
Taheri, Ensiyeh ;
Pashaee, Asrin ;
Mahdavi, Mokhtar .
DESALINATION AND WATER TREATMENT, 2015, 55 (07) :1966-1972
[8]  
EPA, 2005, GUID CARC RISK ASS
[9]  
EPA USEPA, 2012, WATER HLTH, V2012, P644
[10]   Effect of SO2-4/Al3+ ratio and OH-/Al3+ value on the characterization of coagulant poly-aluminum-chloride-sulfate (PACS) and its coagulation performance in water treatment [J].
Gao, BY ;
Yue, QY .
CHEMOSPHERE, 2005, 61 (04) :579-584