Yield of Cardiac Magnetic Resonance Imaging as an Adjunct to Echocardiography in Young Infants With Congenital Heart Disease

被引:9
作者
Johnson, Joyce T. [1 ,2 ]
Molina, Kimberly M. [1 ,2 ]
McFadden, Molly [2 ,3 ]
Minich, L. LuAnn [1 ,2 ]
Menon, Shaji C. [1 ,2 ]
机构
[1] Univ Utah, Dept Pediat, Div Cardiol, Salt Lake City, UT 84113 USA
[2] Primary Childrens Med Ctr, Salt Lake City, UT 84113 USA
[3] Univ Utah, Dept Med, Div Epidemiol, Salt Lake City, UT 84113 USA
基金
美国国家卫生研究院;
关键词
Surgical planning; Cardiac magnetic resonance imaging; Congenital heart disease; Infant; CATHETERIZATION; COMPLICATIONS; ANGIOGRAPHY; MANAGEMENT;
D O I
10.1007/s00246-014-0900-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Echocardiography provides adequate preoperative imaging for most young infants with congenital heart disease (CHD). When anatomic details require further clarification, cardiac magnetic resonance imaging (CMRI) may be useful but adds the risks of sedation or general anesthesia for a vulnerable population. This study aimed to determine the safety of CMRI and its yield of additional significant information for this population. The study identified all infants age 90 days or younger with preoperative echocardiography and a CMRI from the period 2002-2012. Indications, complications, and imaging results were collected. The additional CMRI information was defined as "significant" if it altered surgical management or "not significant" if it did not. Associations between indications for CMRI and the likelihood of new significant findings were sought. For 137 infants (58 % male), CMRI was performed at a median age of 5 days (range, 0-89 days). The CMRI yielded additional information for 76 % (104/137) of the patients. The additional findings were significant for 69 % (72/104) of these patients. The incidence of significant new findings was similar among indication categories. All the infants were intubated. Complications occurred for 5 % of the patients, including one subject with a bradycardic event that prevented completion of the exam and six patients with transient vital sign changes that allowed exam completion. More than 50 % of young infants with CHD who underwent preoperative CMRI had new findings affecting surgical management. Among these patients, CMRI-associated complications were few and predominantly minor for intubated infants. Further studies to determine standard preoperative criteria for the use of CMRI for infants with CHD may help to define appropriate cost-effective use of this diagnostic method.
引用
收藏
页码:1067 / 1071
页数:5
相关论文
共 12 条
[1]   Cardiac computed tomography compared to transthoracic echocardiography in the management of congenital heart disease [J].
Beier, Ulf H. ;
Jelnin, Vladimir ;
Jain, Supriya ;
Ruiz, Carlos E. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (03) :441-449
[2]   CINE MAGNETIC-RESONANCE IMAGING FOR EVALUATION OF CONGENITAL HEART-DISEASE - ROLE IN PEDIATRIC CARDIOLOGY COMPARED WITH ECHOCARDIOGRAPHY AND ANGIOGRAPHY [J].
CHUNG, KJ ;
SIMPSON, IA ;
NEWMAN, R ;
SAHN, DJ ;
SHERMAN, FS ;
HESSELINK, JR .
JOURNAL OF PEDIATRICS, 1988, 113 (06) :1028-1035
[3]   Deep sedation for cardiac magnetic resonance imaging: A comparison with cardiac anesthesia [J].
Fogel, Mark A. ;
Weinberg, Paul M. ;
Parave, Elicia ;
Harris, Christine ;
Montenegro, Lisa ;
Harris, Matthew A. ;
Concepcion, Mikael .
JOURNAL OF PEDIATRICS, 2008, 152 (04) :534-539
[4]   ROLE OF SPIN-ECHO AND CINE MAGNETIC-RESONANCE-IMAGING IN PRESURGICAL PLANNING OF HETEROTAXY SYNDROME - COMPARISON WITH ECHOCARDIOGRAPHY AND CATHETERIZATION [J].
GEVA, T ;
VICK, GW ;
WENDT, RE ;
ROKEY, R .
CIRCULATION, 1994, 90 (01) :348-356
[5]   MAGNETIC-RESONANCE-IMAGING OF HETEROTAXIA IN INFANTS [J].
NIWA, K ;
UCHISHIBA, M ;
AOTSUKA, H ;
TATENO, S ;
TASHIMA, K ;
FUJIWARA, T ;
MATSUO, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (01) :177-183
[6]   BIPLANE INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN CONGENITAL HEART-DISEASE [J].
OLEARY, PW ;
HAGLER, DJ ;
SEWARD, JB ;
TAJIK, AJ ;
SCHAFF, HV ;
PUGA, FJ ;
DANIELSON, GK .
MAYO CLINIC PROCEEDINGS, 1995, 70 (04) :317-326
[7]   Usefulness of magnetic resonance angiography in the evaluation of complex congenital heart disease in Newborns and infants [J].
Prakash, Ashwin ;
Torres, Alejandro J. ;
Printz, Beth F. ;
Prince, Martin R. ;
Nielsen, James C. .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04) :715-721
[8]   Impact of low body weight on frequency of pediatric cardiac catheterization complications [J].
Rhodes, JF ;
Asnes, JD ;
Blaufox, AD ;
Sommer, RJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (11) :1275-+
[9]   THE USEFULNESS OF ECHOCARDIOGRAPHY IN THE SURGICAL-MANAGEMENT OF INFANTS WITH CONGENITAL HEART-DISEASE [J].
SHARMA, S ;
ANAND, R ;
KANTER, KR ;
WILLIAMS, WH ;
DOOLEY, KJ ;
JONES, DW ;
VINCENT, RN .
CLINICAL CARDIOLOGY, 1992, 15 (12) :891-897
[10]   CINE MAGNETIC-RESONANCE IMAGING FOR EVALUATION OF ANATOMY AND FLOW RELATIONS IN INFANTS AND CHILDREN WITH COARCTATION OF THE AORTA [J].
SIMPSON, IA ;
CHUNG, KJ ;
GLASS, RF ;
SAHN, DJ ;
SHERMAN, FS ;
HESSELINK, J .
CIRCULATION, 1988, 78 (01) :142-148