Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak camera

被引:30
作者
Watanabe, T
Sugahara, J
Yoshimatsu, T
Sasaki, S
Sugiyama, Y
Ishi, K
Shibata, Y
Kondo, Y
Yoshii, K
Ueda, T
Uesaka, M
机构
[1] Univ Tokyo, Grad Sch Engn, Nucl Engn Res Lab, Tokai, Ibaraki 3191106, Japan
[2] Tohoku Univ, Sch Engn, Aoba Ku, Sendai, Miyagi 980, Japan
[3] Tohoku Univ, Sci Measurements Res Inst, Aoba Ku, Sendai, Miyagi 98077, Japan
关键词
diagnostics; electron beam; polychromator; interferometer; subpicosecond; coherent;
D O I
10.1016/S0168-9002(01)00952-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Measurements of longitudinal bunch length of subpicosecond and picosecond electron beams have been performed by three methods with three radiation sources at the 35 MeV S-band twin liner accelerators at Nuclear Engineering Research Laboratory, University of Tokyo. The methods we adopt are the femtosecond streak camera with a nondispersive reflective optics, the coherent transition radiation (CTR) Michelson interferometer and the 10 ch polychromator that detects the spectrum of CTR and coherent diffraction radiation (CDR). The measurements by the two CTR methods were independently done with the streak camera and their results were consistent with one another. As a result, the reliability of the polychromator for the diagnostics of less than picosecond electron bunch and the usefulness of the diagnostics for the single shot measurement were verified. Furthermore, perfect nondestructive diagnostics for subpicosecond bunches was performed utilizing CDR interferometry. Then the good agreement between CDR interferometry and the streak camera was obtained. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:315 / 327
页数:13
相关论文
共 26 条
[1]   DISTORTION OF FEMTOSECOND LASER-PULSES IN LENSES AND LENS SYSTEMS [J].
BOR, Z .
JOURNAL OF MODERN OPTICS, 1988, 35 (12) :1907-1918
[2]   Calculation of the noninertial space-charge force and the coherent synchrotron radiation force for short electron bunches in circular motion using the retarded Green's function technique [J].
Carlsten, BE .
PHYSICAL REVIEW E, 1996, 54 (01) :838-845
[3]  
DNESTROVSKII IN, 1959, DOKL AKAD NAUK SSSR+, V124, P792
[4]   BUNCH-SHAPE MONITOR FOR A PICOSECOND SINGLE-BUNCH BEAM OF A 35-MEV ELECTRON LINEAR-ACCELERATOR [J].
HOSONO, Y ;
NAKAZAWA, M ;
IGUCHI, T ;
UEDA, T ;
KOBAYASHI, T ;
KOZAWA, T ;
UESAKA, M ;
OHKUMA, J ;
OKUDA, S ;
YAMAMOTO, T ;
SUEMINE, S .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (9A) :4974-4976
[5]   GENERATION AND MEASUREMENT OF 50-FS (RMS) ELECTRON PULSES [J].
KUNG, P ;
LIHN, HC ;
WIEDEMANN, H ;
BOCEK, D .
PHYSICAL REVIEW LETTERS, 1994, 73 (07) :967-970
[6]   PHASE PROBLEM ASSOCIATED WITH THE DETERMINATION OF THE LONGITUDINAL SHAPE OF A CHARGED-PARTICLE BUNCH FROM ITS COHERENT FAR-IR SPECTRUM [J].
LAI, R ;
SIEVERS, AJ .
PHYSICAL REVIEW E, 1995, 52 (04) :4576-4579
[7]   DETERMINATION OF A CHARGED-PARTICLE-BUNCH SHAPE FROM THE COHERENT FAR-INFRARED SPECTRUM [J].
LAI, R ;
SIEVERS, AJ .
PHYSICAL REVIEW E, 1994, 50 (05) :R3342-R3344
[8]  
NASR H, 2000, NUCL INSTRUM METH A, V455, P149
[9]   OPERATION OF A GRID-SHUTTERED IMAGE CONVERTER TUBE IN PICOSECOND REGION [J].
SCHELEV, MY ;
ALCOCK, AJ ;
RICHARDSON, MC .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (12) :1819-+
[10]   OBSERVATION OF INTERFERENCE BETWEEN COHERENT SYNCHROTRON RADIATION FROM PERIODIC BUNCHES [J].
SHIBATA, Y ;
TAKAHASHI, T ;
ISHI, K ;
ARAI, F ;
MISHIRO, H ;
OHSAKA, T ;
IKEZAWA, M ;
KONDO, Y ;
URASAWA, S ;
NAKAZATO, T ;
KATO, R ;
NIWANO, S ;
OYAMADA, M .
PHYSICAL REVIEW A, 1991, 44 (06) :R3445-R3448