Effective dose estimation in whole-body multislice CT in paediatric trauma patients

被引:21
作者
Munk, Robin D. [1 ]
Strohm, Peter C. [2 ]
Saueressig, Ulrich
Zwingmann, Joern [2 ]
Uhl, Markus [1 ]
Suedkamp, Norbert P. [2 ]
Kotter, Elmar
Langer, Mathias
Bley, Thorsten A.
机构
[1] Univ Hosp, Dept Radiol, Sect Paediat Radiol, D-79095 Freiburg Im Breisgau, Germany
[2] Univ Hosp, Dept Orthopaed & Trauma Surg, D-79095 Freiburg Im Breisgau, Germany
关键词
Polytrauma; Radiation dose; Multislice CT; Children; TUBE CURRENT MODULATION; SPIRAL CT; RADIATION-EXPOSURE; CONVENTIONAL RADIOGRAPHY; REDUCTION; RISKS; CHEST; POLYTRAUMA; CHILDREN; CANCER;
D O I
10.1007/s00247-008-1091-7
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD +/- 7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with relevant information to initiate life-saving therapy. Radiologists should use special paediatric protocols that include dose-saving mechanisms to keep the effective dose as low as possible. Further studies are needed to examine and advance dose-saving strategies in MSCT, especially in children.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 33 条
  • [1] The role of whole body spiral CT in the primary work-up of polytrauma patients - Comparison with conventional radiography and abdominal sonography
    Albrecht, T
    von Schlippenbach, J
    Stahel, PF
    Ertel, W
    Wolf, KJ
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (08): : 1142 - 1150
  • [2] [Anonymous], ICRP PUBL
  • [3] Estimated radiation risks potentially associated with full-body CT screening
    Brenner, DJ
    Elliston, CD
    [J]. RADIOLOGY, 2004, 232 (03) : 735 - 738
  • [4] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [5] *BUND STRAHL, 2006, JAHRB BUND STRAHL 20
  • [6] *EUR COMM, CT SAF EFF BROAD PER
  • [7] CT scan and the pediatric trauma patient - Are we overdoing it?
    Fenton, SJ
    Hansen, KW
    Meyers, RL
    Vargo, DJ
    White, KS
    Firth, SD
    Scaife, ER
    [J]. JOURNAL OF PEDIATRIC SURGERY, 2004, 39 (12) : 1877 - 1881
  • [8] Automatic exposure control to reduce the dose in subsecond multislice spiral CT: Phantom measurements and clinical results
    Greess, H
    Wolf, H
    Suess, C
    Kalender, WA
    Bautz, W
    Baum, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06): : 862 - 869
  • [9] Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    Greess, H
    Lutze, J
    Nömayr, A
    Wolf, H
    Hothorn, T
    Kalender, WA
    Bautz, W
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (06) : 995 - 999
  • [10] Multislice spiral CT (MSCT) in pediatric radiology:: Dose reduction for chest and abdomen examinations
    Honnef, D
    Wildberger, JE
    Stargardt, A
    Hohl, C
    Barker, M
    Günther, RW
    Staatz, G