A prospective randomised multicentre trial comparing 10 Fr Teflon Tannenbaum stents with 10 Fr polyethylene Cotton-Leung stents in patients with malignant common duct strictures

被引:59
作者
England, RE
Martin, DF
Morris, J
Sheridan, MB
Frost, R
Freeman, A
Lawrie, B
Deakin, M
Fraser, I
Smith, K
机构
[1] S Manchester Univ Hosp NHS Trust, Dept Radiol, Manchester M20 2LR, Lancs, England
[2] S Manchester Univ Hosp NHS Trust, Dept Med Stat, Manchester, Lancs, England
[3] St James Hosp, Dept Radiol, Leeds LS9 7TF, W Yorkshire, England
[4] Salisbury Hosp NHS Trust, Dept Radiol, Salisbury, Wilts, England
[5] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
[6] Univ Wales Hosp, Dept Radiol, Cardiff CF4 4XW, S Glam, Wales
[7] N Staffordshire NHS Trust, Dept Surg, Stoke On Trent, Staffs, England
[8] Walsgrave Gen Hosp, Dept Surg, Coventry CV2 2DY, W Midlands, England
[9] SMS Crowthorne, Crowthorne, Berks, England
关键词
biliary prosthesis; patency; bile duct malignancy;
D O I
10.1136/gut.46.3.395
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background-Stent blockage is a multifactorial process in which stent design and materials, bacteria, proteins, and bile viscosity play a role. Aims-To compare the patency of the 10 Fr Teflon Tannenbaum (TT) stent to that of the 10 Fr Cotton-Leung (CL) polyethylene stent with sideholes, in patients with malignant obstructive jaundice. Methods-Patients were recruited to this prospective multicentre randomised study if they had a newly diagnosed malignant bile duct stricture below the hilum of the liver suitable for stenting with a 10 Fr stent. Data were collected and monitored by a professional monitoring company. Primary patency was the interval between stent placement and first exchange or death without recurrent jaundice. Results-134 consecutive patients were recruited between November 1994 and June 1997; 65 were randomised to the TT stent and 69 to the CL stent. Median patency and 95% confidence intervals were 181 (59, 303) days for the TT stent and 133 (92, 174) days for the CL stent, with no significant difference between the two stents (p=0.49). Median survival and 95% confidence intervals were 115 (71, 159) days for the TT stent and 151 (112, 190) days for the CL stent, with no significant difference between the two stents (p=0.765). Conclusion-Neither Teflon as a stent material nor the Tannenbaum design prolong the patency of plastic stents.
引用
收藏
页码:395 / 400
页数:6
相关论文
共 14 条
[1]  
BRUCKNER M, 1990, FORTSCHR GASTROENTER, V20, P17
[2]  
COENE LO, 1990, ENDOSCOPIC BILIARY S, P135
[3]   CLOGGING OF BILIARY ENDOPROSTHESES - A NEW PERSPECTIVE [J].
COENE, PPLO ;
GROEN, AK ;
CHENG, J ;
OUT, MMJ ;
TYTGAT, GNJ ;
HUIBREGTSE, K .
GUT, 1990, 31 (08) :913-917
[4]   THE ROLE OF BACTERIA IN THE BLOCKAGE OF BILIARY STENTS [J].
LEUNG, JWC ;
LING, TKW ;
VALLANCEOWEN, J .
GASTROINTESTINAL ENDOSCOPY, 1988, 34 (01) :19-22
[5]   ENDOSCOPIC BILIARY PROSTHESES - A COMPARISON OF MATERIALS [J].
LEUNG, JWC ;
DELFAVERO, G ;
COTTON, PB .
GASTROINTESTINAL ENDOSCOPY, 1985, 31 (02) :93-95
[6]  
MARTIN DF, 1998, CLIN PRACTICE ERCP, P53
[7]   EXPERIMENTAL-STUDY OF BILIARY ENDOPROSTHESIS EFFICIENCY [J].
REY, JF ;
MAUPETIT, P ;
GREFF, M .
ENDOSCOPY, 1985, 17 (04) :145-148
[8]   PROLONGED PATENCY WITH A NEW-DESIGN TEFLON BILIARY PROSTHESIS [J].
SEITZ, U ;
VADEYAR, H ;
SOEHENDRA, N .
ENDOSCOPY, 1994, 26 (05) :478-482
[9]   OPTIMAL PALLIATION OF MALIGNANT BILE-DUCT OBSTRUCTION - EXPERIENCE WITH ENDOSCOPIC-12 FRENCH PROSTHESES [J].
SIEGEL, JH ;
PULLANO, W ;
KODSI, B ;
COOPERMAN, A ;
RAMSEY, W .
ENDOSCOPY, 1988, 20 (04) :137-141
[10]   BILIARY STENT BLOCKAGE WITH BACTERIAL BIOFILM - A LIGHT AND ELECTRON-MICROSCOPY STUDY [J].
SPEER, AG ;
COTTON, PB ;
RODE, J ;
SEDDON, AM ;
NEAL, CR ;
HOLTON, J ;
COSTERTON, JW .
ANNALS OF INTERNAL MEDICINE, 1988, 108 (04) :546-553