A data reduction and compression description for high throughput time-resolved electron microscopy

被引:11
作者
Datta, Abhik [1 ,2 ]
Ng, Kian Fong [1 ,2 ]
Balakrishnan, Deepan [1 ,2 ]
Ding, Melissa [3 ]
Chee, See Wee [1 ,2 ,4 ]
Ban, Yvonne [1 ,2 ]
Shi, Jian [1 ,2 ]
Loh, N. Duane [1 ,2 ,4 ]
机构
[1] Natl Univ Singapore, Ctr BioImaging Sci, Singapore, Singapore
[2] Natl Univ Singapore, Dept Biol Sci, Singapore, Singapore
[3] Ohio State Univ, Dept Comp Sci & Engn, Columbus, OH 43210 USA
[4] Natl Univ Singapore, Dept Phys, Singapore, Singapore
基金
新加坡国家研究基金会;
关键词
MOTION; TEM;
D O I
10.1038/s41467-020-20694-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fast, direct electron detectors have significantly improved the spatio-temporal resolution of electron microscopy movies. Preserving both spatial and temporal resolution in extended observations, however, requires storing prohibitively large amounts of data. Here, we describe an efficient and flexible data reduction and compression scheme (ReCoDe) that retains both spatial and temporal resolution by preserving individual electron events. Running ReCoDe on a workstation we demonstrate on-the-fly reduction and compression of raw data streaming off a detector at 3 GB/s, for hours of uninterrupted data collection. The output was 100-fold smaller than the raw data and saved directly onto network-attached storage drives over a 10 GbE connection. We discuss calibration techniques that support electron detection and counting (e.g., estimate electron backscattering rates, false positive rates, and data compressibility), and novel data analysis methods enabled by ReCoDe (e.g., recalibration of data post acquisition, and accurate estimation of coincidence loss). The use of electron detectors with high spatio-temporal resolution is limited by the large amounts of data generated. Here, the authors describe ReCoDe, a data reduction and compression scheme, that preserves individual electron events, and enable on-the-fly reduction and compression of raw data.
引用
收藏
页数:15
相关论文
共 37 条
[21]  
Johnson I. J, 2016, 2016 IEEE NUCL SCI S, P1
[22]  
Klein A., 2017, BACKBLAZE BLOG CLOUD
[23]   Fast electron tomography: Applications to beam sensitive samples and in situ TEM or operando environmental TEM studies [J].
Koneti, Siddardha ;
Roiban, Lucian ;
Dalmas, Florent ;
Langlois, Cyril ;
Gay, Anne-Sophie ;
Cabiac, Amandine ;
Grenier, Thomas ;
Banjak, Hussein ;
Maxim, Voichita ;
Epicier, Thierry .
MATERIALS CHARACTERIZATION, 2019, 151 :480-495
[24]   Tracking the picoscale spatial motion of atomic columns during dynamic structural change [J].
Levin, Barnaby D. A. ;
Lawrence, Ethan L. ;
Crozier, Peter A. .
ULTRAMICROSCOPY, 2020, 213
[25]   Influence of electron dose rate on electron counting images recorded with the K2 camera [J].
Li, Xueming ;
Zheng, Shawn Q. ;
Egami, Kiyoshi ;
Agard, David A. ;
Cheng, Yifan .
JOURNAL OF STRUCTURAL BIOLOGY, 2013, 184 (02) :251-260
[26]   Facet development during platinum nanocube growth [J].
Liao, Hong-Gang ;
Zherebetskyy, Danylo ;
Xin, Huolin ;
Czarnik, Cory ;
Ercius, Peter ;
Elmlund, Hans ;
Pan, Ming ;
Wang, Lin-Wang ;
Zheng, Haimei .
SCIENCE, 2014, 345 (6199) :916-919
[27]  
Loh ND, 2017, NAT CHEM, V9, P77, DOI [10.1038/nchem.2618, 10.1038/NCHEM.2618]
[28]   A compression scheme for radio data in high performance computing [J].
Masui, K. ;
Amiri, M. ;
Connor, L. ;
Deng, M. ;
Fandino, M. ;
Hoefer, C. ;
Halpern, M. ;
Hanna, D. ;
Hincks, A. D. ;
Hinshaw, G. ;
Parra, J. M. ;
Newburgh, L. B. ;
Shaw, J. R. ;
Vanderlinde, K. .
ASTRONOMY AND COMPUTING, 2015, 12 :181-190
[29]  
McCallum J.C., 2019, DISK DRIVE PRICES 19
[30]   MRCZ - A file format for cryo-TEM data with fast compression [J].
McLeod, Robert A. ;
Righetto, Ricardo Diogo ;
Stewart, Andy ;
Stahlberg, Henning .
JOURNAL OF STRUCTURAL BIOLOGY, 2018, 201 (03) :252-257