High sensitive and linear pressure sensor for ultra-low pressure measurement

被引:6
|
作者
Huang, Xian [1 ,2 ]
Zhang, Dacheng [2 ]
机构
[1] Peking Univ, Shenzhen Grad Sch, Shenzhen 518055, Peoples R China
[2] Peking Univ, Inst Microelect, Beijing 100871, Peoples R China
来源
28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014) | 2014年 / 87卷
关键词
Pressure sensor; high sensitive and linear; ultra-low pressure; peninsula-structured diaphragm; finite element method;
D O I
10.1016/j.proeng.2014.11.383
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A novel peninsula-structured diaphragm with specially designed piezoresistors was proposed in our present pressure sensor for ultra-low pressure measurement. Finite element method (FEM) was adopted for analyzing the sensor performance. In comparison to typical sensors with flat and center-bossed diaphragms, the optimized sensor design could achieve excellent sensitivity and linearity. In accordance with the FEM results, the fabricated pressure sensor showed a sensitivity of 18.4mV/V full-scale output and a nonlinearity error of 0.36% FSS in the pressure range 0-5kPa. The proposed sensor structure is potentially a better choice for measuring low pressures. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1202 / 1205
页数:4
相关论文
共 50 条
  • [1] Flexible microhyperboloids facets giant sensitive ultra-low pressure sensor
    Kumar, Shubham
    Bijender
    Yadav, Sanjay
    Kumara, Ashok
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 328
  • [2] Ultra-low pressure sensor for neonatal resuscitator
    Jacq, C.
    Maeder, T.
    Haemmerle, E.
    Craquelin, N.
    Ryser, P.
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 172 (01) : 135 - 139
  • [3] Ultra-low pressure sensor for neonatal resuscitator
    Jacq, C.
    Maeder, T.
    Haemmerle, E.
    Craquelin, N.
    Ryser, P.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 532 - 535
  • [4] The Calibration of the Pressure Sensor at the Ultra-low Temperature
    Zhang, Jian
    Zhang, Binzhen
    Ji, Changhong
    Liu, Jianlin
    Li, Xianghong
    INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS SCIENCE, PTS 1 AND 2, 2011, 80-81 : 698 - 703
  • [5] Design of a Graphene Capacitive Pressure Sensor for Ultra-low Pressure Detection
    Zhang, Yangxi
    Gui, Yiming
    Meng, Fanrui
    Gao, Chengchen
    Hao, Yilong
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [6] Design of an Ultra-low Pressure Sensor Based on The Growth of Graphene on Silicon Dioxide Surface
    Tran, Quochung
    Gao, Chengchen
    Hao, Yilong
    2017 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2017, : 526 - 529
  • [7] Highly sensitive giant magnetoresistance (GMR) based ultra low differential pressure sensor
    Borole, Umesh P.
    Subramaniam, Sasikala
    Kulkarni, Ishan R.
    Saravanan, P.
    Barshilia, Harish C.
    Chowdhury, P.
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 280 : 125 - 131
  • [8] A bossed diaphragm piezoresistive pressure sensor with a peninsula-island structure for the ultra-low-pressure range with high sensitivity
    Zhao, Libo
    Xu, Tingzhong
    Hebibul, Rahman
    Jiang, Zhuangde
    Ding, Jianjun
    Peng, Niancai
    Guo, Xin
    Xu, Yu
    Wang, Hongyan
    Zhao, Yulong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (12)
  • [9] Capacitive Micromachined Ultrasonic Transducer for Ultra-low Pressure Detection
    Li, Zhikang
    Zhao, Libo
    Jiang, Zhuangde
    Ye, Zhiying
    Zhao, Yulong
    2014 9TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2014, : 602 - 605
  • [10] Ultra-Low Power Frequency and Duty-cycle Modulated Implantable Pressure-Temperature Sensor
    Khairi, Ahmad
    Wu, Chenyang
    Rabin, Yoed
    Fedder, Gary
    Paramesh, Jeyanandh
    Schwartzman, David
    2013 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2013, : 226 - 229