Deep Residual Networks for Quantification of Muscle Fiber Orientation and Curvature from Ultrasound Images

被引:23
作者
Cunningham, Ryan [1 ]
Harding, Peter [1 ]
Loram, Ian [1 ]
机构
[1] Manchester Metropolitan Univ, Manchester, Lancs, England
来源
MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017) | 2017年 / 723卷
关键词
Ultrasound; Muscle analysis; Residual networks; Convolutional networks; Wavelet; Fiber orientation; ACHILLES-TENDON FORCES; BUCKLE TRANSDUCER; OPTIC FIBER; JOINT ANGLE; LIGAMENT; WALKING;
D O I
10.1007/978-3-319-60964-5_6
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper concerns fully automatic and objective measurement of human skeletal muscle fiber orientation directly from standard b-mode ultrasound images using deep residual (ResNet) and convolutional neural networks (CNN). Fiber orientation and length is related with active and passive states of force production within muscle. There is currently no non-invasive way to measure force directly from muscle. Measurement of forces and other contractile parameters like muscle length change, thickness, and tendon length is not only important for understanding healthy muscle, but such information has contributed to understanding, diagnosis, monitoring, targeting and treatment of diseases ranging from myositis to stroke and motor neurone disease (MND). We applied well established deep learning methods to ultrasound data recorded from 19 healthy participants (5 female, ages: 30 +/- 7.7) and achieved state of the art accuracy in predicting fiber orientation directly from ultrasound images of the calf muscles. First we used a previously developed segmentation technique to extract a region of interest within the gastrocnemius muscle. Then we asked an expert to annotate the main line of fiber orientation in 4 x 4 partitions of 400 normalized images. A linear model was then applied to the annotations to regulate and recover the orientation field for each image. Then we applied a CNN and a ResNet to predict the fiber orientation in each image. With leave one participant out cross-validation and dropout as a regulariser, we were able to demonstrate state of the art performance, recovering the fiber orientation with an average error of just 2 degrees.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 29 条
[1]  
[Anonymous], 1989, P ADV NEUR INF PROC
[2]   DESIGN AND PERFORMANCE OF A MODIFIED BUCKLE TRANSDUCER FOR THE MEASUREMENT OF LIGAMENT TENSION [J].
BARRY, D ;
AHMED, AM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (02) :149-152
[3]   Real-Time Ultrasound Segmentation, Analysis and Visualisation of Deep Cervical Muscle Structure [J].
Cunningham, Ryan J. ;
Harding, Peter J. ;
Loram, Ian D. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (02) :653-665
[4]   Estimating Skeletal Muscle Fascicle Curvature From B-Mode Ultrasound Image Sequences [J].
Darby, John ;
Li, Baihua ;
Costen, Nicholas ;
Loram, Ian ;
Hodson-Tole, Emma .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) :1935-1945
[5]   Automated regional analysis of B-mode ultrasound images of skeletal muscle movement [J].
Darby, John ;
Hodson-Tole, Emma F. ;
Costen, Nicholas ;
Loram, Ian D. .
JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (02) :313-327
[6]   In vivo human triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump [J].
Finni, T ;
Komi, PV ;
Lepola, V .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 83 (4-5) :416-426
[7]   Achilles tendon loading during walking: application of a novel optic fiber technique [J].
Finni, T ;
Komi, PV ;
Lukkariniemi, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1998, 77 (03) :289-291
[8]  
Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195
[9]  
GREGOR RJ, 1987, INT J SPORTS MED, V8, P9
[10]   Ultrasound-Based Detection of Fasciculations in Healthy and Diseased Muscles [J].
Harding, Peter John ;
Loram, Ian D. ;
Combes, Nicholas ;
Hodson-Tole, Emma F. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) :512-518