Assessment of Left Ventricular Volumes with Echocardiography and Cardiac Magnetic Resonance Imaging: Real-Life Evaluation of Standard versus New Semiautomatic Methods

被引:42
作者
Aurich, Matthias [1 ]
Andre, Florian [1 ]
Keller, Marius [1 ]
Greiner, Sebastian [1 ]
Hess, Alexander [1 ]
Buss, Sebastian J. [1 ]
Katus, Hugo A. [1 ]
Mereles, Derliz [1 ]
机构
[1] Heidelberg Univ, Dept Internal Med 3, Heidelberg, Germany
关键词
Volumetry; Ejection fraction; Systolic function; TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY; AUTOMATED BORDER-DETECTION; EJECTION FRACTION; MYOCARDIAL-INFARCTION; EUROPEAN-SOCIETY; HEART-FAILURE; RECOMMENDATIONS; QUANTIFICATION; QUANTITATION; VALIDATION;
D O I
10.1016/j.echo.2014.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Routine quantitative assessment of left ventricular (LV) volumes with echocardiography is hindered by time-consuming methods requiring a manual trace of the LV cavity from two apical two-dimensional planes. Thus, the aim of this study was to evaluate faster new semiautomatic echocardiographic methods that could represent a feasible alternative for the assessment of LV volumes and ejection fraction (EF) in clinical practice. Methods: Two semiautomatic methods, the automated EF (Auto-EF) for two-dimensional echocardiography and the 4D Auto LVQ tool for three-dimensional echocardiography (3DE), were compared with the biplane modified Simpson's method and cardiac magnetic resonance (CMR) imaging in 47 patients. To evaluate the accuracy of volumetry, additional in vitro measurements using water-filled latex balloons were performed with both modalities. Results: Results of balloon volumetry by echocardiography and CMR measurements were in good agreement with real balloon volumes. The mean LV EF was 45 +/- 11% by Auto-EF, 45 +/- 11% by 3DE, 48 +/- 11% by Simpson's method, and 54 +/- 12% by CMR. Linear regression and Bland-Altman analyses showed good associations for semiautomatic methods with Simpson's method (Auto-EF, r = 0.85, bias = 3%, limits of agreement [LOA] = 12%; 3DE, r = 0.79, bias = 3%, LOA = 14%), as well as with CMR (Auto-EF, r = 0.74, bias = 9%, LOA = 17%; 3DE, r = 0.73, bias = 9%, LOA = 17%). Intra-and interobserver variability were 6% and 12% with Auto-EF and 8% and 11% with 3DE, respectively. Conclusions: Good correlations between semiautomatic echocardiographic parameters for assessment of LV volumes and EF could be observed when compared with Simpson's method or CMR. However, intertechnique agreement analysis of absolute LV volumes revealed considerable differences, with significant underestimation of volumes and EF with respect to CMR.
引用
收藏
页码:1017 / 1024
页数:8
相关论文
共 25 条
[1]   A novel two-dimensional echocardinarraphic image analysis system using artificial intelligence-learned pattern recognition for rapid automated ejection fraction [J].
Cannesson, Maxime ;
Tanabe, Masaki ;
Suffoletto, Matthew S. ;
McNamara, Dennis M. ;
Madan, Shobhit ;
Lacomis, Joan M. ;
Gorcsan, John, III .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (02) :217-226
[2]   Performance of 3-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction [J].
Dorosz, Jennifer L. ;
Lezotte, Dennis C. ;
Weitzenkamp, David A. ;
Allen, Larry A. ;
Salcedo, Ernesto E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (20) :1799-1808
[3]   Cardiovascular magnetic resonance artefacts [J].
Ferreira, Pedro F. ;
Gatehouse, Peter D. ;
Mohiaddin, Raad H. ;
Firmin, David N. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
[4]   Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data [J].
Jacobs, LD ;
Salgo, IS ;
Goonewardena, S ;
Weinert, L ;
Coon, P ;
Bardo, D ;
Gerard, O ;
Allain, P ;
Zamorano, JL ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
EUROPEAN HEART JOURNAL, 2006, 27 (04) :460-468
[5]   Reconstructed versus real-time 3-dimensional echocardiography: Comparison with magnetic resonance imaging [J].
Jenkins, Carly ;
Leano, Rodel ;
Chan, Jonathan ;
Marwick, Thomas H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (07) :862-868
[6]   Recommendations for cardiovascular magnetic resonance in adults with congenital heart disease from the respective working groups of the European Society of Cardiology [J].
Kilner, Philip J. ;
Geva, Tal ;
Kaemmerer, Harald ;
Trindade, Pedro T. ;
Schwitter, Juerg ;
Webb, Gary D. .
EUROPEAN HEART JOURNAL, 2010, 31 (07) :794-805
[7]   FACTORS PREDICTING MORTALITY IN IDIOPATHIC DILATED CARDIOMYOPATHY [J].
KOMAJDA, M ;
JAIS, JP ;
REEVES, F ;
GOLDEARB, B ;
BOUHOUR, JB ;
JUILLIERES, Y ;
LANFRANCHI, J ;
PEYCELON, P ;
GESLIN, P ;
CARRIE, D ;
GROSGOGEAT, Y .
EUROPEAN HEART JOURNAL, 1990, 11 (09) :824-831
[8]   High-resolution transthoracic real-time three-dimensional echocardiography -: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging [J].
Kuhl, HP ;
Schreckenberg, M ;
Rulands, D ;
Katoh, M ;
Schäfer, W ;
Schummers, G ;
Bücker, A ;
Hanrath, P ;
Franke, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :2083-2090
[9]   Recommendations for chamber quantification: A report from the American Society of Echocardiography's guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology [J].
Lang, RM ;
Bierig, M ;
Devereux, RB ;
Flachskampf, FA ;
Foster, E ;
Pellikka, PA ;
Picard, MH ;
Roman, MJ ;
Seward, J ;
Shanewise, JS ;
Solomon, SD ;
Spencer, KT ;
Sutton, MS ;
Stewart, WJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) :1440-1463
[10]   EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography [J].
Lang, Roberto M. ;
Badano, Luigi P. ;
Tsang, Wendy ;
Adams, David H. ;
Agricola, Eustachio ;
Buck, Thomas ;
Faletra, Francesco F. ;
Franke, Andreas ;
Hung, Judy ;
Perez de Isla, Leopoldo ;
Kamp, Otto ;
Kasprzak, Jaroslaw D. ;
Lancellotti, Patrizio ;
Marwick, Thomas H. ;
McCulloch, Marti L. ;
Monaghan, Mark J. ;
Nihoyannopoulos, Petros ;
Pandian, Natesa G. ;
Pellikka, Patricia A. ;
Pepi, Mauro ;
Roberson, David A. ;
Shernan, Stanton K. ;
Shirali, Girish S. ;
Sugeng, Lissa ;
Ten Cate, Folkert J. ;
Vannan, Mani A. ;
Luis Zamorano, Jose ;
Zoghbi, William A. .