Undersampled Radial MR Acquisition and Highly Constrained Back Projection (HYPR) Reconstruction: Potential Medical Imaging Applications in the Post-Nyquist Era

被引:50
作者
Mistretta, Charles A. [1 ]
机构
[1] Univ Wisconsin, Wisconsin Inst Med Res, UW Int Ctr Accelerated Med Imaging, Madison, WI 53706 USA
关键词
VIPR; HYPR; undersampling; acceleration; SNR enhancement; K-T BLAST; PHASE-CONTRAST; DYNAMIC MRI; ANGIOGRAPHY; RESOLUTION; STENOSIS; IMAGES; SENSE;
D O I
10.1002/jmri.21683
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
During the past several years there has been extensive study of alternative MR acquisition strategies such as spiral and radial. Vastly undersampled imaging with projections (VIPR) is a three-dimensional (313) radial acquisition that provides acceptable images while violating the Nyquist theorem by factors of up to several hundred. For applications like magnetic resonance angiography (MRA), VIPR provides sparse data sets with incoherent artifacts that satisfy the requirements of emerging reconstruction approaches like iterative image norm minimization (compressed sensing) and highly constrained back projection (HYPR). All of these tools can be used in combination with parallel imaging to provide extremely high acceleration factors in MR]. In this review we do not attempt to do justice to the many exciting developments in the general field of constrained reconstruction but focus on preliminary results using VIPR and HYPR for non-Cartesian, Nyquist-violating MRI and the extension of HYPR processing to a broad range of medical imaging applications in which the acquisitions satisfy the Nyquist theorem but lack sufficient signal-to-noise ratio (SNR), leading to the possibility of radiation reduction, increased ultrasound resolution and field-of-view, and improved dynamic display of radiotracers.
引用
收藏
页码:501 / 516
页数:16
相关论文
共 71 条
  • [1] ALEXANDER A, 2006, P 14 ANN M ISMRM SEA
  • [2] Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    Barger, AV
    Block, WF
    Toropov, Y
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 297 - 305
  • [3] Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information
    Candès, EJ
    Romberg, J
    Tao, T
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) : 489 - 509
  • [4] Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    Chen, Guang-Hong
    Tang, Jie
    Leng, Shuai
    [J]. MEDICAL PHYSICS, 2008, 35 (02) : 660 - 663
  • [5] Scleromyxoedema-like cutaneous diseases in renal-dialysis patients
    Cowper, SE
    Robin, HS
    Steinberg, SM
    Su, LD
    Gupta, S
    LeBoit, PE
    [J]. LANCET, 2000, 356 (9234) : 1000 - 1001
  • [6] Compressed sensing
    Donoho, DL
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) : 1289 - 1306
  • [7] DU J, MAGN RESON IN PRESS
  • [8] Simple correction method for k-space trajectory deviations in MRI
    Duyn, JH
    Yang, YH
    Frank, JA
    van der Veen, JW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) : 150 - 153
  • [9] EDELMAN RR, 2008, P 16 ANN M ISMRM TOR
  • [10] ERTEL D, 2008, ACCURATE IN VIVO DET