MOA resistive current on-line monitoring and expert diagnosis system

被引:1
|
作者
Wu, Mengmeng [1 ]
Xu, Jun [1 ]
Yi, Bo [1 ]
机构
[1] Univ Sci & Technol China, Dept Phys, Hefei 230026, Peoples R China
来源
ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING II, PTS 1-3 | 2013年 / 433-435卷
关键词
metal oxide arrester; resistive current; on-line monitoring; expert diagnosis system; FFT algorithm;
D O I
10.4028/www.scientific.net/AMM.433-435.856
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents metal oxide arresters (MOA) resistive current on-line monitoring and expert diagnosis system. The system combined the harmonic analysis method and the compensation method to measure the MOA resistive current. The on-line monitoring system used MAX11046 for signal AID conversion and TMS320F2812 DSP for data processing. It used EEC 60870-5-103 protocol to upload the data to the expert diagnosis system through the RS-485 bus. Based on the real-time monitoring data, the historical data and the environmental parameters, the expert diagnosis system can analyze and judge the MOA status. The system adopted many anti-jamming measures to make the measurement data stable and accurate. The results show that the resistive current of the 35KV MOA fluctuates based on 20 mu A.
引用
收藏
页码:856 / +
页数:2
相关论文
共 50 条
  • [1] The design of synchronous sampling unit in on-line resistive leakage current monitoring system of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    Li, YQ
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 472 - 475
  • [2] Influence of power system's harmonic voltage and interphase interference to on-line resistive leakage current monitoring of MOA
    Wang Yongqiang
    Lu Fangcheng
    Shang Jing
    Li Heming
    CEEM' 2006: ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, VOLS 1 AND 2, PROCEEDINGS, 2006, : 620 - +
  • [3] On-line resistive leakage current monitoring method of MOA consider the influence of power system's harmonic voltage and interphase
    Wang, YQ
    Lu, FC
    Li, HM
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 3, 2005, : 332 - 335
  • [4] Influence of interphase interference to on-line leakage current monitoring of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    2004 4th INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY PROCEEDINGS, 2004, : 916 - 919
  • [5] Influence of power system's harmonic voltage on on-line leakage current monitoring of MOA
    Wang, YQ
    Lu, FC
    Li, HM
    2004 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL ELECTROMAGNETICS AND ITS APPLICATIONS, PROCEEDINGS, 2004, : 268 - 271
  • [6] Design and Implementation of Synchronous Wireless On-line Detection System of MOA Resistive Current in Electric Power System Based on GPS
    Cui, Tao
    Cao, Yongxing
    Xu, An
    Li, Juelong
    Sheng, Gehao
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ELECTRICAL ENGINEERING, 2013, 676 : 312 - 317
  • [8] On-line monitoring the leaky current of MOA with optical-fiber sampling technology
    Zhou, Xiao-Wei
    Gaoya Dianqi/High Voltage Apparatus, 2001, 37 (06):
  • [9] THE ON-LINE MONITORING AND DIAGNOSIS SYSTEM FOR REFINING PROCESS
    Zhou, Xin
    Zhang, Feng
    Li, Yingchun
    PROCEEDING OF INTERNATIONAL MECHANICAL PULPING CONFERENCE 2011, 2011, : 535 - 538
  • [10] An on-line expert system for fault section diagnosis in power systems
    Vazquez, E
    Chacon, OL
    Altuve, HJ
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1997, 12 (01) : 357 - 362