Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry

被引:8
|
作者
Suzuki, Satoshi [1 ]
Sotomi, Yohei [1 ]
Kobayashi, Tomoaki [1 ]
Hamanaka, Yuma [1 ]
Nakatani, Shimpei [1 ]
Shiojima, Ichiro [2 ]
Sakata, Yasushi [3 ]
Hirayama, Atsushi [1 ]
Higuchi, Yoshiharu [1 ]
机构
[1] Osaka Police Hosp, Dept Cardiol, Tennoji Ku, 10-31 Kitayama, Osaka 5430035, Japan
[2] Kansai Med Univ, Dept Med 2, Hirakata, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Cardiovasc Med, Osaka, Japan
关键词
Coronary angioscopy; Drug-eluting stent; Biodegradable polymer; Durable polymer; CORONARY-ARTERIES;
D O I
10.1007/s10554-019-01580-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the vessel healing status 3months after stent implantation of bioresorbable-polymer drug-eluting stents (BP-DESs) in comparison with durable-polymer DESs (DP-DESs) by angioscopy. Study design was a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful angioscopic examination at planned 3-month follow-up after the DES implantation in the native coronary artery were enrolled. We evaluated main, maximum, minimum strut coverage grades and coverage heterogeneity score defined as a difference between maximum and minimum coverage grades. All lesions were divided into three segments: proximal, mid, and distal segments. A total of 108 patients (66.6 +/- 10years) with 124 lesions were analyzed (BP-DES 57 patients 61 lesions 226 segments vs. DP-DES 57 patients 63 lesions 203 segments; six patients had both BP-DES and DP-DES). Patient and lesion demographics, procedural characteristics were well balanced. Main coverage grade (mean +/- standard error; 1.08 +/- 0.02 vs. 1.05 +/- 0.03, p=0.354) and minimum coverage grade (1.00 +/- 0.00 vs. 1.00 +/- 0.00, p>0.999) were not significantly different between BP-DES and DP-DES groups. Maximum coverage grade was significantly higher in the BP-DES than in the DP-DES (1.45 +/- 0.04 vs. 1.35 +/- 0.04, p=0.049). Coverage heterogeneity score did not differ between BP-DES and DP-DES groups (1.05 +/- 0.07 vs. 0.90 +/- 0.07, p=0.162). At 3-month follow-up, the current BP-DES had higher maximum stent coverage than the contemporary DP-DES, while main and minimum coverage grades and heterogeneity of the neointimal coverage were comparable. Further prospective randomized trials should be conducted to evaluate the clinical significance of the present imaging results.
引用
收藏
页码:973 / 980
页数:8
相关论文
共 50 条
  • [41] Percutaneous Treatment of Unprotected Left Main Disease With Thin-Strut Durable-Polymer or Early Generation Thicker-Strutted and Coated Bioabsorbable-Polymer Drug-Eluting Stents in a Large-Scale Registry
    Lee, Michael S.
    Kang, Jeehoon
    Park, Kyung Woo
    Cho, Haechan
    Lee, Hak Seung
    Han, Jung-Kyu
    Yang, Han-Mo
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Kim, Hyo-Soo
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 32 : 43 - 49
  • [42] One-month DAPT after biodegradable-polymer everolimus-eluting stent implantation in women at high-bleeding risk: Insights from the POEM trial
    Maurina, Matteo
    Pivato, Carlo Andrea
    Kunadian, Vijay
    Testa, Luca
    Briguori, Carlo
    Pacchioni, Andrea
    Latini, Alessia Chiara
    Cesani, Nicola
    Piccolo, Raffale
    Musto, Carmine
    Sardella, Gennaro
    Indolfi, Ciro
    Regazzoli, Damiano
    Paradies, Valeria
    Stefanini, Giulio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (06) : 1129 - 1138
  • [43] Clinical outcomes of patients treated using very short duration dual antiplatelet therapy after implantation of biodegradable-polymer drug-eluting stents: rationale and design of a prospective multicenter REIWA registry
    Ishida, Masaru
    Takahashi, Fumiaki
    Goto, Iwao
    Niiyama, Masanobu
    Saitoh, Hidenori
    Sakamoto, Tsubasa
    Maegawa, Yuko
    Osaki, Takuya
    Nishiyama, Osamu
    Endo, Hiroshi
    Sakamoto, Ryohei
    Kojima, Tsuyoshi
    Koeda, Yorihiko
    Kimura, Takumi
    Itoh, Tomonori
    Morino, Yoshihiro
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (04) : 398 - 404
  • [44] Clinical outcomes of patients treated using very short duration dual antiplatelet therapy after implantation of biodegradable-polymer drug-eluting stents: rationale and design of a prospective multicenter REIWA registry
    Masaru Ishida
    Fumiaki Takahashi
    Iwao Goto
    Masanobu Niiyama
    Hidenori Saitoh
    Tsubasa Sakamoto
    Yuko Maegawa
    Takuya Osaki
    Osamu Nishiyama
    Hiroshi Endo
    Ryohei Sakamoto
    Tsuyoshi Kojima
    Yorihiko Koeda
    Takumi Kimura
    Tomonori Itoh
    Yoshihiro Morino
    Cardiovascular Intervention and Therapeutics, 2020, 35 : 398 - 404
  • [45] Healing course of acute vessel wall injury after drug-eluting stent implantation assessed by optical coherence tomography
    De Cock, Dries
    Bennett, Johan
    Ughi, Giovanni J.
    Dubois, Christophe
    Sinnaeve, Peter
    Dhooge, Jan
    Desmet, Walter
    Belmans, Ann
    Adriaenssens, Tom
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (07) : 800 - 809
  • [46] Sustained clinical safety and efficacy of a biodegradable-polymer coated sirolimus-eluting stent in "real-world" practice: Three-year outcomes of the CREATE (multi-center registry of EXCEL biodegradable polymer drug eluting stents) study
    Han, Yaling
    Jing, Quanmin
    Li, Yi
    Yang, Lixia
    Liu, Huiliang
    Shang, Xiaoming
    Jiang, Tiemin
    Li, Zhanquan
    Zhang, Hua
    Yan, Gaoliang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (02) : 211 - 216
  • [47] Satisfactory arterial repair 1year after ultrathin strut biodegradable polymer sirolimus-eluting stent implantation: an angioscopic observation
    Ishihara, Takayuki
    Awata, Masaki
    Iida, Osamu
    Fujita, Masashi
    Masuda, Masaharu
    Okamoto, Shin
    Nanto, Kiyonori
    Kanda, Takashi
    Tsujimura, Takuya
    Uematsu, Masaaki
    Mano, Toshiaki
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2019, 34 (01) : 34 - 39
  • [48] Long-term outcomes of biodegradable polymer versus durable polymer drug-eluting stents in patients with diabetes a pooled analysis of individual patient data from 3 randomized trials
    de Waha, Antoinette
    Stefanini, Giulio G.
    King, Lamin A.
    Byrne, Robert A.
    Serruys, Patrick W.
    Kufner, Sebastian
    Meier, Bernhard
    Jueni, Peter
    Kastrati, Adnan
    Windecker, Stephan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (06) : 5162 - 5166
  • [49] Impact of bioresorbable versus permanent polymer on long-term vessel wall inflammation and healing: a comparative drug-eluting stent experimental study
    Wilson, Gregory J.
    McGregor, Jennifer
    Conditt, Gerard
    Shibuya, Masahiko
    Sushkova, Natalia
    Eppihimer, Michael J.
    Hawley, Steven P.
    Rousselle, Serge D.
    Huibregtse, Barbara A.
    Dawkins, Keith D.
    Granada, Juan F.
    EUROINTERVENTION, 2018, 13 (14) : 1670 - 1679
  • [50] Impact of procedural and patient-related risks on 1-year outcomes for patients treated with 1-month dual antiplatelet therapy followed by P2Y12 inhibitor monotherapy after biodegradable-polymer drug-eluting stent implantation
    Shimada, Ryutaro
    Ishida, Masaru
    Takahashi, Fumiaki
    Niiyama, Masanobu
    Ishisone, Takenori
    Matsumoto, Yuki
    Taguchi, Yuya
    Osaki, Takuya
    Nishiyama, Osamu
    Endo, Hiroshi
    Sakamoto, Ryohei
    Tanaka, Kentaro
    Koeda, Yorihiko
    Kimura, Takumi
    Goto, Iwao
    Ninomiya, Ryo
    Sasaki, Wataru
    Shimada, Kaho
    Itoh, Tomonori
    Morino, Yoshihiro
    REIWA investigators
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2025, 40 (02) : 327 - 336