Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry

被引:8
|
作者
Suzuki, Satoshi [1 ]
Sotomi, Yohei [1 ]
Kobayashi, Tomoaki [1 ]
Hamanaka, Yuma [1 ]
Nakatani, Shimpei [1 ]
Shiojima, Ichiro [2 ]
Sakata, Yasushi [3 ]
Hirayama, Atsushi [1 ]
Higuchi, Yoshiharu [1 ]
机构
[1] Osaka Police Hosp, Dept Cardiol, Tennoji Ku, 10-31 Kitayama, Osaka 5430035, Japan
[2] Kansai Med Univ, Dept Med 2, Hirakata, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Cardiovasc Med, Osaka, Japan
关键词
Coronary angioscopy; Drug-eluting stent; Biodegradable polymer; Durable polymer; CORONARY-ARTERIES;
D O I
10.1007/s10554-019-01580-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the vessel healing status 3months after stent implantation of bioresorbable-polymer drug-eluting stents (BP-DESs) in comparison with durable-polymer DESs (DP-DESs) by angioscopy. Study design was a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful angioscopic examination at planned 3-month follow-up after the DES implantation in the native coronary artery were enrolled. We evaluated main, maximum, minimum strut coverage grades and coverage heterogeneity score defined as a difference between maximum and minimum coverage grades. All lesions were divided into three segments: proximal, mid, and distal segments. A total of 108 patients (66.6 +/- 10years) with 124 lesions were analyzed (BP-DES 57 patients 61 lesions 226 segments vs. DP-DES 57 patients 63 lesions 203 segments; six patients had both BP-DES and DP-DES). Patient and lesion demographics, procedural characteristics were well balanced. Main coverage grade (mean +/- standard error; 1.08 +/- 0.02 vs. 1.05 +/- 0.03, p=0.354) and minimum coverage grade (1.00 +/- 0.00 vs. 1.00 +/- 0.00, p>0.999) were not significantly different between BP-DES and DP-DES groups. Maximum coverage grade was significantly higher in the BP-DES than in the DP-DES (1.45 +/- 0.04 vs. 1.35 +/- 0.04, p=0.049). Coverage heterogeneity score did not differ between BP-DES and DP-DES groups (1.05 +/- 0.07 vs. 0.90 +/- 0.07, p=0.162). At 3-month follow-up, the current BP-DES had higher maximum stent coverage than the contemporary DP-DES, while main and minimum coverage grades and heterogeneity of the neointimal coverage were comparable. Further prospective randomized trials should be conducted to evaluate the clinical significance of the present imaging results.
引用
收藏
页码:973 / 980
页数:8
相关论文
共 50 条
  • [21] Differential impact of abluminal groove-filled biodegradable-polymer sirolimus-eluting stent versus durable-polymer everolimus-eluting stent on and off dual antiplatelet therapy
    Saito, Yuichi
    Wijns, William
    Baumbach, Andreas
    Xu, Bo
    Kelbaek, Henning
    Zheng, Ming
    Morel, Marie-angele
    Anderson, Richard
    Schaechinger, Volker
    Lansky, Alexandra
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (02) : 357 - 365
  • [22] Stent Thrombosis with Biodegradable Polymer Drug-Eluting Stents versus Durable Polymer Sirolimus-Eluting Stents: An Update Meta-Analysis
    Zhu, Lin
    Lv, Yi Ning
    Wang, Li Yu
    CARDIOLOGY, 2015, 130 (02) : 96 - 105
  • [23] Impact of 12-Month Angioscopic Thrombi and Yellow Plaque After Drug-Eluting Stent Implantation
    Nishino, Masami
    Egami, Yasuyuki
    Nohara, Hiroaki
    Kawanami, Shodai
    Ukita, Kohei
    Kawamura, Akito
    Yasumoto, Koji
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Shiraki, Tatsuya
    Nakamura, Daisuke
    Mizote, Isamu
    Ishihara, Takayuki
    Mano, Toshiaki
    Ueno, Takafumi
    Nakatani, Daisaku
    Hikoso, Shungo
    Nanto, Shinsuke
    Sakata, Yasushi
    CIRCULATION JOURNAL, 2024, 88 (11) : 1758 - 1767
  • [24] Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1113 - 1119
  • [25] Difference of vascular healing between bioabsorbable-polymer and durable-polymer new generation drug-eluting stents: an optical coherence tomographic analysis
    Yutaka Matsuhiro
    Daisuke Nakamura
    Ryu Shutta
    Akito Kawamura
    Hitoshi Nakamura
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Yasuyuki Egami
    Yasushi Sakata
    Masami Nishino
    Jun Tanouchi
    The International Journal of Cardiovascular Imaging, 2021, 37 : 1131 - 1141
  • [26] Difference of vascular healing between bioabsorbable-polymer and durable-polymer new generation drug-eluting stents: an optical coherence tomographic analysis
    Matsuhiro, Yutaka
    Nakamura, Daisuke
    Shutta, Ryu
    Kawamura, Akito
    Nakamura, Hitoshi
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Egami, Yasuyuki
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (04) : 1131 - 1141
  • [27] Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease
    Shen, Li
    Yang, Wei
    Yin, Jia-Sheng
    Liu, Xue-Bo
    Wu, Yi-Zhe
    Sun, Ai-Jun
    Qian, Ju-Ying
    Ge, Jun-Bo
    CHINESE MEDICAL JOURNAL, 2015, 128 (06) : 768 - 773
  • [28] Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease
    Shen Li
    Yang Wei
    Yin Jia-Sheng
    Liu Xue-Bo
    Wu Yi-Zhe
    Sun Ai-Jun
    Qian Ju-Ying
    Ge Jun-Bo
    中华医学杂志英文版, 2015, 128 (06) : 768 - 773
  • [29] Dual Antiplatelet Therapy for 6 Versus 18 Months After Biodegradable Polymer Drug-Eluting Stent Implantation
    Nakamura, Masato
    Iijima, Raisuke
    Ako, Junya
    Shinke, Toshiro
    Okada, Hisayuki
    Ito, Yoshiaki
    Ando, Kenji
    Anzai, Hitoshi
    Tanaka, Hiroyuki
    Ueda, Yasunori
    Takiuchi, Shin
    Nishida, Yasunori
    Ohira, Hiroshi
    Kawaguchi, Katsuhiro
    Kadotani, Makoto
    Niinuma, Hiroyuki
    Omiya, Kazuto
    Morita, Takashi
    Zen, Kan
    Yasaka, Yoshinori
    Inoue, Kenji
    Ishiwata, Sugao
    Ochiai, Masahiko
    Hamasaki, Toshimitsu
    Yokoi, Hiroyoshi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12) : 1189 - 1198
  • [30] Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent Sequential Optical Coherence Tomography Study
    Ogura, Kunihiro
    Tsujita, Hiroaki
    Oishi, Yosuke
    Matsumoto, Hidenari
    Matsukawa, Naoki
    Sakai, Rikuo
    Arai, Taito
    Sato, Shunya
    Tanaka, Hideaki
    Masaki, Ryota
    Arai, Ken
    Nomura, Kosuke
    Kosaki, Ryota
    Sakai, Koshiro
    Sekimoto, Teruo
    Kondo, Seita
    Tsukamoto, Shigeto
    Mori, Hiroyoshi
    Yamamoto, Myong Hwa
    Wakabayashi, Kohei
    Suzuki, Hiroshi
    Ochiai, Masahiko
    Shinke, Toshiro
    INTERNATIONAL HEART JOURNAL, 2021, 62 (03) : 510 - 519