Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry

被引:8
|
作者
Suzuki, Satoshi [1 ]
Sotomi, Yohei [1 ]
Kobayashi, Tomoaki [1 ]
Hamanaka, Yuma [1 ]
Nakatani, Shimpei [1 ]
Shiojima, Ichiro [2 ]
Sakata, Yasushi [3 ]
Hirayama, Atsushi [1 ]
Higuchi, Yoshiharu [1 ]
机构
[1] Osaka Police Hosp, Dept Cardiol, Tennoji Ku, 10-31 Kitayama, Osaka 5430035, Japan
[2] Kansai Med Univ, Dept Med 2, Hirakata, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Cardiovasc Med, Osaka, Japan
关键词
Coronary angioscopy; Drug-eluting stent; Biodegradable polymer; Durable polymer; CORONARY-ARTERIES;
D O I
10.1007/s10554-019-01580-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the vessel healing status 3months after stent implantation of bioresorbable-polymer drug-eluting stents (BP-DESs) in comparison with durable-polymer DESs (DP-DESs) by angioscopy. Study design was a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful angioscopic examination at planned 3-month follow-up after the DES implantation in the native coronary artery were enrolled. We evaluated main, maximum, minimum strut coverage grades and coverage heterogeneity score defined as a difference between maximum and minimum coverage grades. All lesions were divided into three segments: proximal, mid, and distal segments. A total of 108 patients (66.6 +/- 10years) with 124 lesions were analyzed (BP-DES 57 patients 61 lesions 226 segments vs. DP-DES 57 patients 63 lesions 203 segments; six patients had both BP-DES and DP-DES). Patient and lesion demographics, procedural characteristics were well balanced. Main coverage grade (mean +/- standard error; 1.08 +/- 0.02 vs. 1.05 +/- 0.03, p=0.354) and minimum coverage grade (1.00 +/- 0.00 vs. 1.00 +/- 0.00, p>0.999) were not significantly different between BP-DES and DP-DES groups. Maximum coverage grade was significantly higher in the BP-DES than in the DP-DES (1.45 +/- 0.04 vs. 1.35 +/- 0.04, p=0.049). Coverage heterogeneity score did not differ between BP-DES and DP-DES groups (1.05 +/- 0.07 vs. 0.90 +/- 0.07, p=0.162). At 3-month follow-up, the current BP-DES had higher maximum stent coverage than the contemporary DP-DES, while main and minimum coverage grades and heterogeneity of the neointimal coverage were comparable. Further prospective randomized trials should be conducted to evaluate the clinical significance of the present imaging results.
引用
收藏
页码:973 / 980
页数:8
相关论文
共 50 条
  • [1] Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry
    Satoshi Suzuki
    Yohei Sotomi
    Tomoaki Kobayashi
    Yuma Hamanaka
    Shimpei Nakatani
    Ichiro Shiojima
    Yasushi Sakata
    Atsushi Hirayama
    Yoshiharu Higuchi
    The International Journal of Cardiovascular Imaging, 2019, 35 : 973 - 980
  • [2] Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry
    Tomoaki Kobayashi
    Yohei Sotomi
    Satoshi Suzuki
    Yuma Hamanaka
    Shimpei Nakatani
    Jouke Dijkstra
    Yoshinobu Onuma
    Patrick W. Serruys
    Yasushi Sakata
    Atsushi Hirayama
    Yoshiharu Higuchi
    The International Journal of Cardiovascular Imaging, 2020, 36 : 205 - 215
  • [3] Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry
    Kobayashi, Tomoaki
    Sotomi, Yohei
    Suzuki, Satoshi
    Hamanaka, Yuma
    Nakatani, Shimpei
    Dijkstra, Jouke
    Onuma, Yoshinobu
    Serruys, Patrick W.
    Sakata, Yasushi
    Hirayama, Atsushi
    Higuchi, Yoshiharu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (02) : 205 - 215
  • [4] NOBORI™ biodegradable-polymer biolimus-eluting stent versus durable-polymer drug-eluting stents: A meta-analysis
    Zhang, Yao-Jun
    Ye, Fei
    Iqbal, Javaid
    Dong, Sheng-Jie
    Bourantas, Christos V.
    Tian, Nai-Liang
    Serruys, Patrick W.
    Chen, Shao-Liang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (01) : 151 - 153
  • [5] Temporal course of vascular healing and neoatherosclerosis after implantation of durable- or biodegradable-polymer drug-eluting stents
    Guagliumi, Giulio
    Shimamura, Kunihiro
    Sirbu, Vasite
    Garbo, Roberto
    Boccuzzi, Giacomo
    Vassileva, Angelina
    Valsecchi, Orazio
    Fiocca, Luigi
    Canova, Paolo
    Colombo, Francesco
    Pereira, Gabriel Tensot Rodriguez
    Nakamura, Daisuke
    Attizzani, Guitherme F.
    Cereda, Alberto
    Satogami, Keisuke
    De Luca, Eonardo
    Saia, Francesco
    Capodanno, Davide
    EUROPEAN HEART JOURNAL, 2018, 39 (26) : 2448 - +
  • [6] Impact of different coronary angioscopic findings on arterial healing one year after bioresorbable-polymer and second-generation durable-polymer drug-eluting stent implantation
    Nojima, Yuhei
    Adachi, Hidenori
    Ihara, Madoka
    Kurimoto, Tetsuya
    Okayama, Keita
    Sakata, Yasushi
    Nanto, Shinsuke
    JOURNAL OF CARDIOLOGY, 2020, 76 (04) : 371 - 377
  • [7] Early- and middle-phase arterial repair following bioresorbable- and durable-polymer drug-eluting stent implantation: An angioscopic study
    Ishihara, Takayuki
    Tsujimura, Takuya
    Okuno, Shota
    Iida, Osamu
    Asai, Mitsutoshi
    Masuda, Masaharu
    Okamoto, Shin
    Nanto, Kiyonori
    Kanda, Takashi
    Matsuda, Yasuhiro
    Mano, Toshiaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 285 : 27 - 31
  • [8] Comparison of Endothelial Barrier Functional Recovery After Implantation of a Novel Biodegradable-Polymer Sirolimus-Eluting Stent in Comparison to Durable- and Biodegradable-Polymer Everolimus-Eluting Stents
    Sakamoto, Atsushi
    Torii, Sho
    Jinnouchi, Hiroyuki
    Guo, Liang
    Cornelissen, Anne
    Kuntz, Salome
    Cheng, Qi
    Fernandez, Raquel
    Paek, Ka Hyun
    Harris, Kathryn
    Srivastava, Mukta C.
    Kolodgie, Frank D.
    Virmani, Renu
    Finn, Aloke, V
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 24 : 1 - 10
  • [9] Biodegradable- Versus Durable-Polymer Drug-Eluting Stents for STEMI
    Pilgrim, Thomas
    Muller, Olivier
    Heg, Dik
    Roffi, Marco
    Kurz, David J.
    Moarof, Igal
    Weilenmann, Daniel
    Kaiser, Christoph
    Tapponnier, Maxime
    Losdat, Sylvain
    Eeckhout, Eric
    Valgimigli, Marco
    Juni, Peter
    Windecker, Stephan
    Iglesias, Juan F.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (06) : 639 - 648
  • [10] Long-Term Clinical Outcomes of Biodegradable-Polymer Drug-Eluting Stents Versus Second-Generation Durable-Polymer Drug-Eluting Stents for ST-Segment Elevation Myocardial Infarction
    Sim, Hui Wen
    Thong, Elizabeth H.
    Djohan, Andie H.
    Chen, Jason Z.
    Ser, Joon Sin
    Loh, Poay Huan
    Lee, Chi-Hang
    Chan, Mark Y.
    Low, Adrian F.
    Tay, Edgar L.
    Chan, Koo Hui
    Tan, Huay Cheem
    Loh, Joshua P.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 35 : 98 - 103