Temperature and humidity consideration for calculating airborne 222Rn using activated charcoal canisters

被引:17
作者
El Samman, H [1 ]
Arafa, W
Abd alla, A
机构
[1] Menoufia Univ, Fac Sci, Shibin Al Kawm, Egypt
[2] Ain Shams Univ, Fac Women, Cairo, Egypt
[3] Ain Shams Univ, Fac Educ, Cairo, Egypt
来源
HEALTH PHYSICS | 2002年 / 83卷 / 01期
关键词
radon; charcoal canisters; calibration; humidity; relative;
D O I
10.1097/00004032-200207000-00011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A radon calibration chamber with variable and controlled radon concentration, humidity, and temperature was constructed and used to extend the calibration range of open-faced and diffusion-barrier charcoal canisters for higher temperature and humidity applications. The optimum exposure time to achieve the best detection accuracy and the lowest minimum detectable level was between 2 and 4 d depending on relative humidity for open-faced canister and 4 d for diffusion barrier canister over a range of humidity. The dependence of radon adsorption on the temperature was also studied for both types of canister at different values of relative humidity. The open-faced canisters at 15degreesC absorb 68% more radon than at 30degreesC over the range of humidity from 20% to 80%. The diffusion-barrier canister shows insignificant variation in absorption over the same range of temperature and humidity.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 16 条
[1]   SOME IMPROVEMENTS OF CHARCOAL MEASUREMENT TECHNIQUES USED FOR INDOOR RADON MEASUREMENTS IN QATAR [J].
ARAFA, WM ;
ALNEIMI, H ;
ALHOUTY, L ;
ABOULEILA, H .
RADIATION PHYSICS AND CHEMISTRY, 1994, 44 (1-2) :237-240
[2]  
BIGU J, 1986, HEALTH PHYS, V51, P534
[3]   A DIFFUSION BARRIER CHARCOAL ADSORPTION COLLECTOR FOR MEASURING RN CONCENTRATIONS IN INDOOR AIR [J].
COHEN, BL ;
NASON, R .
HEALTH PHYSICS, 1986, 50 (04) :457-463
[4]   AN IMPROVED PASSIVE ACTIVATED-C COLLECTOR FOR MEASURING ENVIRONMENTAL RN-222 IN INDOOR AIR [J].
GEORGE, AC ;
WEBER, T .
HEALTH PHYSICS, 1990, 58 (05) :583-589
[5]   PASSIVE, INTEGRATED MEASUREMENT OF INDOOR RADON USING ACTIVATED CARBON [J].
GEORGE, AC .
HEALTH PHYSICS, 1984, 46 (04) :867-872
[6]  
Gray DJ, 1987, 520587005 US EPA
[7]  
GRAY DJ, 1990, BIII6 US EPA
[8]   ADSORPTION OF RN-222 BY OPEN-FACED AND DIFFUSION-BARRIER CANISTERS AT DIFFERENT CONDITIONS OF TEMPERATURE AND HUMIDITY [J].
LUETZELSCHWAB, JW ;
HASTINGS, L ;
ELLIS, SM .
HEALTH PHYSICS, 1994, 66 (01) :63-71
[9]   PERFORMANCE OF A DIFFUSION BARRIER CHARCOAL ADSORPTION RN-222 MONITOR UNDER CONDITIONS OF VARYING HUMIDITY AND TEMPERATURE [J].
POJER, PM ;
PEGGIE, JR ;
OBRIEN, RS ;
SOLOMON, SB ;
WISE, KN .
HEALTH PHYSICS, 1990, 58 (01) :13-19
[10]   A PASSIVE DIFFUSION RN-222 SAMPLER BASED ON ACTIVATED CARBON ADSORPTION [J].
PRICHARD, HM ;
MARIEN, K .
HEALTH PHYSICS, 1985, 48 (06) :797-803