Microtensile bond strength analysis of adhesive systems to Er:YAG and Er,Cr:YSGG laser-treated dentin

被引:30
|
作者
Ramos, Thaysa Monteiro [1 ]
Ramos-Oliveira, Thayanne Monteiro [1 ]
Moretto, Simone Goncalves [1 ]
de Freitas, Patricia Moreira [1 ]
Esteves-Oliveira, Marcella [2 ]
Eduardo, Carlos de Paula [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Restorat Dent, Special Lab Lasers Dent LELO, BR-05508000 Sao Paulo, Brazil
[2] Rhein Westfal TH Aachen, Dept Operat Dent Periodontol & Prevent Dent ZPP, D-52074 Aachen, Germany
基金
巴西圣保罗研究基金会;
关键词
Dentin; Er:YAG laser; Er; Cr:YSGG laser; SEM; Microtensile bond strength; ER-YAG-LASER; SELF-ETCHING PRIMER; BUR-CUT; CAVITY PREPARATION; WATER STORAGE; SURFACE; RESIN; ACID; ENAMEL; MICROLEAKAGE;
D O I
10.1007/s10103-012-1261-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this in vitro study was to evaluate the effect of different surface treatments (control, diamond bur, erbium-doped yttrium aluminum garnet (Er:YAG) laser, and erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser) on sound dentin surface morphology and on microtensile bond strength (mu TBS). Sixteen dentin fragments were randomly divided into four groups (n = 4), and different surface treatments were analyzed by scanning electron microscopy. Ninety-six third molars were randomly divided into eight groups (n = 12) according to type of surface treatment and adhesive system: G1 = Control + Clearfil SE Bond (SE); G2 = Control + Single Bond (SB); G3 = diamond bur (DB) + SE; G4 = DB + SB, G5 = Er:YAG laser (2.94 mu m, 60 mJ, 2 Hz, 0.12 W, 19.3 J/cm(2)) + SE; G6 = Er:YAG + SB, G7 = Er,Cr:YSGG laser (2.78 mu m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm(2)) + SE; and G8 = Er,Cr:YSGG + SB. Composite blocks were bonded to the samples, and after 24-h storage in distilled/deionized water (37 A degrees C), stick-shaped samples were obtained and submitted to mu TBS test. Bond strength values (in megapascal) were analyzed by two-way ANOVA and Tukey tests (alpha = 0.05). G1 (54.69 A +/- 7.8 MPa) showed the highest mean, which was statistically significantly higher than all the other groups (p < 0.05). For all treatments, SE showed higher bond strength than SB, except only for Er,Cr:YSGG treatment, in which the systems did not differ statistically from each other. Based on the irradiation parameters considered in this study, it can be concluded that Er:YAG and Er,Cr:YSGG irradiation presented lower values than the control group; however, their association with self-etching adhesive does not have a significantly negative effect on sound dentin (mu TBS values of > 20 MPa).
引用
收藏
页码:565 / 573
页数:9
相关论文
共 50 条
  • [21] Effect of Er,Cr:YSGG laser irradiation and self-etch adhesive systems on hypermineralized dentin: a bond strength evaluation
    da Costa Neves, Tamiris
    Leandrin, Thais Piragine
    Wajngarten, Danielle
    Besegato, Joao Felipe
    de Campos, Edson Alves
    LASER PHYSICS, 2020, 30 (06)
  • [22] Effects of Er:YAG and Er,Cr:YSGG laser irradiation on the adhesion to eroded dentin
    Thaysa Monteiro Ramos
    Thayanne Monteiro Ramos-Oliveira
    Patricia Moreira de Freitas
    Nilton Azambuja
    Marcella Esteves-Oliveira
    Norbert Gutknecht
    Carlos de Paula Eduardo
    Lasers in Medical Science, 2015, 30 : 17 - 26
  • [23] In Vitro Microleakage of Composite Restorations Prepared by Er:YAG/Er,Cr:YSGG Lasers and Conventional Drills Associated with Two Adhesive Systems
    Moldes, Vera Lucia
    Capp, Claudia Ines
    Navarro, Ricardo Scarparo
    Matos, Adriana Bona
    Youssef, Michel Nicolau
    Cassoni, Alessandra
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (03) : 221 - 229
  • [24] Effects of Er,Cr:YSGG Laser Pulse Frequency on Microtensile Bond Strength to Enamel
    Ayar, M. K.
    Yildirim, T.
    OPERATIVE DENTISTRY, 2017, 42 (01) : 53 - 61
  • [25] Microtensile bond strength of resin composite to dentin treated with Er:YAG laser of bleached teeth
    Eduardo dos Santos Leonetti
    José Augusto Rodrigues
    André Figueiredo Reis
    Ricardo Scarparo Navarro
    Ana Cecília Correa Aranha
    Alessandra Cassoni
    Lasers in Medical Science, 2012, 27 : 31 - 38
  • [26] Effects of the Er, Cr:YSGG laser irradiation on dentin bond strength
    Piccioni, M. A. R. V.
    Neves, T. P. C.
    Kubo, C. S.
    Saad, J. R. C.
    Campos, E. A.
    LASER PHYSICS, 2016, 26 (02)
  • [27] Effect of Er,Cr:YSGG on bond strength and microleakage of dentin bonded to resin composite with different distance and irradiation time
    Almojaly, Saud Abdulaziz
    Al-Hamdan, Rana Sulaiman
    Alrahlah, Ali
    Qutub, Osama A.
    Alnajashi, Sulaiman
    Vohra, Fahim
    Abduljabbar, Tariq
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2019, 25 : 204 - 207
  • [28] Analysis of the interfacial micromorphology of adhesive systems in cavities prepared with Er,Cr: YSGG, Er: YAG laser and bur
    Correa Aranha, Ana Cecilia
    Eduardo, Carlos De Paula
    Gutknecht, Norbnert
    Marques, Marcia Martins
    Ramalho, Karen Mueler
    Apel, Christian
    MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (08) : 745 - 751
  • [29] Effect of Er: YAG Laser on Microtensile Bond Strength of Bleached Dentin to Composite
    Rezaei, Mohsen
    Aliasghar, Elham
    Rezvani, Mohammad Bagher
    Chiniforush, Nasim
    Moradi, Zohreh
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2019, 10 (02) : 117 - 124
  • [30] THE EFFECT OF ER,CR:YSGG LASER CONDITIONING ON DENTIN BOND STRENGTH AND NANOLEAKAGE OF UNIVERSAL ADHESIVE SYSTEMS: AN IN VITRO STUDY
    Karatas, Ozcan
    Sagsoz, Omer
    Kapti, Zeynep Sumeyye
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 : S156 - S167