Enhancement of Confinement in Scaled RC Columns using Steel Fibers Extracted from Scrap Tyres

被引:12
作者
Ahmad, Izaz [1 ]
Iqbal, Mudasir [1 ,2 ]
Abbas, Asim [1 ]
Badrashi, Yasir Irfan [1 ]
Jamal, Arshad [3 ]
Ullah, Shahid [1 ]
Yosri, Ahmed M. [4 ,5 ]
Hamad, Moustafa [5 ,6 ]
机构
[1] Univ Engn & Technol, Dept Civil Engn, Peshawar 25120, Pakistan
[2] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, Shanghai Key Lab Digital Maintenance Bldg & Infra, Shanghai 200240, Peoples R China
[3] Imam Abdulrahman Bin Faisal Univ, Coll Engn, Transportat & Traff Engn Dept, POB 1982, Dammam 31451, Saudi Arabia
[4] Jouf Univ, Coll Engn, Dept Civil Engn, Sakakah 72388, Saudi Arabia
[5] Delta Univ Sci & Technol, Fac Engn, Civil Engn Dept, Belkas 11152, Egypt
[6] Al Baha Univ, Coll Engn, Dept Civil Engn, Al Baha 65731, Saudi Arabia
关键词
reinforced concrete columns; steel fibers; confinement; compressive strength; REINFORCED-CONCRETE COLUMNS; BEHAVIOR; PERFORMANCE;
D O I
10.3390/ma15093219
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Steel fibers are widely extracted from scrap tyres, causing environmental concerns. This paper presents the use of steel fibers in variable proportions extracted from scrap tyres. The enhancement of the confinement was envisaged through the addition of steel fibers obtained from scrap tyres. The study included an experimental program for the development of constitutive material models for ordinary Portland cement (OPC) concrete and concrete with added steel fibers. A mix design was carried out for OPC, targeting a compressive strength of 3000 psi. Steel fibers were added to OPC in ratios of 1.0% to 3.0%, with an increment of 0.5%. Concrete columns, with cross-sectional dimensions of 6 x 6 inches and a length of 30 inches, were cast with both OPC and fiber-reinforced concrete. The column confinement was evaluated with a different spacing of ties (3- and 4-inch center-to-center). Compression tests on the concrete columns indicate that the addition of steel fibers to a concrete matrix results in an appreciable increase in strength and ductility. Overall, increasing the percentage of steel fibers increased the compression strength and the ductility of concrete. The maximum strain in the concrete containing 2.5% steel fibers increased by 285% as compared to the concrete containing 1% of steel fibers. An optimum percentage of 2.5% steel fibers added to the concrete resulted in a 39% increase in compressive strength, accompanied by a significant improvement in ductility. The optimum content of steel fibers, when used in confined columns, showed that confined compression strength increased with the addition of steel fibers. However, it is recommended that additional columns on the basis of the optimum steel fiber content shall be tested to evaluate their effectiveness in reducing the stirrup spacing.
引用
收藏
页数:13
相关论文
共 47 条
[1]   Use of steel fibres recovered from waste tyres as reinforcement in concrete: Pull-out behaviour, compressive and flexural strength [J].
Aiello, M. A. ;
Leuzzi, F. ;
Centonze, G. ;
Maffezzoli, A. .
WASTE MANAGEMENT, 2009, 29 (06) :1960-1970
[2]  
[Anonymous], 2010, C469C469M10 ASTM INT
[3]  
[Anonymous], 1973, Proceedings of the American Concrete Institute Journal, V70, P729
[4]  
[Anonymous], 2017, ASTM Standard No. A370
[5]  
ASTM, 2001, C12715 ASTM INT
[6]  
ASTM, 2009, C18814 ASTM, P109
[7]  
ASTM, 1994, C786C786M17 ASTM
[8]  
ASTM, 2001, C128 ASTM
[9]  
ASTM, 2002, C143 ASTM
[10]   Influence of Fiber Reinforced Concrete on Plastic Behavior on Exterior Beam Column Joint under Cyclic Loading [J].
Bharti, Raman ;
Chidambaram, R. Siva ;
Kwatra, Naveen .
PLASTICITY AND IMPACT MECHANICS, 2017, 173 :1122-1129