Totally endoscopic atrial septal defect repair with robotic assistance

被引:1
作者
Argenziano, N
Oz, MC
DeRose, JJ
Ashton, RC
Beck, J
Wang, F
Chitwood, WR
Nifong, LW
Dimitui, J
Rose, EA
Smith, CR
机构
[1] Columbia Univ Coll Phys & Surg, Div Cardiothorac Surg, New York, NY 10032 USA
[2] E Carolina Univ, Sch Med, Dept Cardiothorac Surg, Greenville, NC USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The development of minimally invasive cardiac surgery has been characterized by the performance of increasingly complex operations through progressively smaller incisions. Computer (robotic) enhancement has emerged as a potential facilitator of these procedures, initially by providing enhanced endoscopic camera control and, more recently, by allowing the manipulation of surgical instruments through limited thoracic incisions. This report describes the next step in this progression, namely the performance of an atrial septal defect (ASD) repair entirely through thoracoscopic port incisions. This represents the first U.S. application of robotic technology for totally endoscopic open-heart surgery Materials and Methods: A 33-year-old woman with a secundum atrial septal defect underwent totally endoscopic repair through four port incisions by means of the Da Vinci(TM) (Intuitive Surgical, Mountain View, CA) robotic surgical system. Cardiopulmonary bypass was achieved peripherally (femoral Estech endoaortic balloon cannula; femoral and right internal jugular venous Bio-medicus cannulae). The myocardium was protected with antegrade cold blood cardioplegia delivered through the distal port of the arterial cannula. After port insertion, the entire operation, including pericardiotomy, bicaval occlusion, atriotomy, atrial septopexy, and atrial closure, was performed by computer-aided control of a camera and two instrument arms manipulated by a surgeon seated 15 feet away. The fourth port was used for suction and suture passage by the patient-side assistant. The aortic cross-clamp time was 43 minutes, and the postoperative transesophageal echocardiogram demonstrated normal ventricular function and the absence of interatrial shunting. The patient was extubated on the night of surgery, was ambulatory within 15 hours, and was discharged on the morning of postoperative day 3, 63 hours after the procedure. At 30-day follow-up, the patient was well and without complaints, and transthoracic echocardiogram confirmed the continued absence of interatrial shunting. Conclusions: Computer-aided robotic surgical technology can be used to perform open-heart procedures with a totally endoscopic approach. The benefits of this approach may include decreased perioperative pain, decreased recovery times, and improved cosmesis and patient acceptance. Clinical trials currently in progress will demonstrate whether this technology will be of reproducible value in the management of patients with intracardiac disease on a larger scale.
引用
收藏
页码:294 / 297
页数:4
相关论文
共 50 条
  • [41] Total endoscopic repair of atrial septal defect under on-pump beating heart
    Tang, Yihu
    Wu, Yanhu
    Zhu, Jinfu
    Liu, Xiang
    Zhou, Jinxin
    Huang, Haobing
    Li, Mingke
    Dai, Yawei
    Han, Xu
    JOURNAL OF THORACIC DISEASE, 2018, 10 (12) : 6557 - 6562
  • [42] REPAIR OF ATRIAL SEPTAL DEFECT IN EBSTEINS MALFORMATION
    CARTMILL, TB
    CELERMAJ.JM
    BERNSTEI.L
    BOWDLER, JD
    AUSTRALASIAN ANNALS OF MEDICINE, 1970, 19 (02): : 186 - &
  • [43] Atrial septal defect repair gone wrong
    Bloomingdale, Richard
    Ashraf, Said
    Cardozo, Shaun
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (02): : 315 - 316
  • [44] Stroke after repair of atrial septal defect
    Cheng, TO
    ANNALS OF THORACIC SURGERY, 2000, 69 (03) : 981 - 981
  • [45] SECUNDUM ATRIAL SEPTAL-DEFECT REPAIR
    KHALID, MI
    POSTGRADUATE MEDICAL JOURNAL, 1994, 70 (825) : 522 - 523
  • [46] ATRIAL SEPTAL DEFECT - RESULTS OF REPAIR IN ADULTS
    HANLON, CR
    BARNER, HB
    WILLMAN, VL
    MUDD, JG
    KAISER, GC
    ARCHIVES OF SURGERY, 1969, 99 (02) : 275 - &
  • [47] Robotic repair of atrial septal defect: Pre-groove vertical right atriotomy approach
    Kim, Kitae
    Kim, Yun Seok
    Kim, Hong Rae
    Kim, Ho Jin
    Yoo, Jae Suk
    Kim, Joon Bum
    Jung, Sung-Ho
    Lee, Jae Won
    JTCVS TECHNIQUES, 2024, 28 : 73 - 81
  • [48] TECHNIQUE FOR REPAIR OF ATRIAL SEPTAL DEFECT USING THE ATRIAL WELL
    KIRKLIN, JW
    ELLIS, FH
    BARRATTBOYES, BG
    SURGERY GYNECOLOGY & OBSTETRICS, 1956, 103 (05): : 646 - 649
  • [49] Robotic mitral valve repair and closure of atrial septal defect. Report of 13 procedures
    Sepulveda, Edgardo
    Ibanez, Anibal
    Baeza, Cristian
    Espindola, Manuel
    Sepulveda, Gustavo
    Maureira, Mauricio
    Pablo Uribe, Juan
    Salas, Cristian
    REVISTA MEDICA DE CHILE, 2019, 147 (10) : 1303 - 1307
  • [50] Atrial arrhythmias before and after atrial septal defect repair
    Mantovan, R
    Gatzoulis, M
    Pedrocco, A
    De Leo, A
    Salvador, L
    Valfrè, C
    Stritoni, P
    Zecchel, R
    EUROPEAN HEART JOURNAL, 2001, 22 : 125 - 125