Totally endoscopic atrial septal defect repair with robotic assistance

被引:1
|
作者
Argenziano, N
Oz, MC
DeRose, JJ
Ashton, RC
Beck, J
Wang, F
Chitwood, WR
Nifong, LW
Dimitui, J
Rose, EA
Smith, CR
机构
[1] Columbia Univ Coll Phys & Surg, Div Cardiothorac Surg, New York, NY 10032 USA
[2] E Carolina Univ, Sch Med, Dept Cardiothorac Surg, Greenville, NC USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The development of minimally invasive cardiac surgery has been characterized by the performance of increasingly complex operations through progressively smaller incisions. Computer (robotic) enhancement has emerged as a potential facilitator of these procedures, initially by providing enhanced endoscopic camera control and, more recently, by allowing the manipulation of surgical instruments through limited thoracic incisions. This report describes the next step in this progression, namely the performance of an atrial septal defect (ASD) repair entirely through thoracoscopic port incisions. This represents the first U.S. application of robotic technology for totally endoscopic open-heart surgery Materials and Methods: A 33-year-old woman with a secundum atrial septal defect underwent totally endoscopic repair through four port incisions by means of the Da Vinci(TM) (Intuitive Surgical, Mountain View, CA) robotic surgical system. Cardiopulmonary bypass was achieved peripherally (femoral Estech endoaortic balloon cannula; femoral and right internal jugular venous Bio-medicus cannulae). The myocardium was protected with antegrade cold blood cardioplegia delivered through the distal port of the arterial cannula. After port insertion, the entire operation, including pericardiotomy, bicaval occlusion, atriotomy, atrial septopexy, and atrial closure, was performed by computer-aided control of a camera and two instrument arms manipulated by a surgeon seated 15 feet away. The fourth port was used for suction and suture passage by the patient-side assistant. The aortic cross-clamp time was 43 minutes, and the postoperative transesophageal echocardiogram demonstrated normal ventricular function and the absence of interatrial shunting. The patient was extubated on the night of surgery, was ambulatory within 15 hours, and was discharged on the morning of postoperative day 3, 63 hours after the procedure. At 30-day follow-up, the patient was well and without complaints, and transthoracic echocardiogram confirmed the continued absence of interatrial shunting. Conclusions: Computer-aided robotic surgical technology can be used to perform open-heart procedures with a totally endoscopic approach. The benefits of this approach may include decreased perioperative pain, decreased recovery times, and improved cosmesis and patient acceptance. Clinical trials currently in progress will demonstrate whether this technology will be of reproducible value in the management of patients with intracardiac disease on a larger scale.
引用
收藏
页码:294 / 297
页数:4
相关论文
共 50 条
  • [21] Totally endoscopic removal of dislocated atrial septal defect - closure devices
    Schachner, Thomas
    Grimm, Michael
    Bonaros, Nikolaos
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 1082 - 1082
  • [22] Three-port totally endoscopic repair vs conventional median sternotomy for atrial septal defect
    Junji Yanagisawa
    Atsuo Maekawa
    Sadanari Sawaki
    Masayoshi Tokoro
    Takahiro Ozeki
    Mamoru Orii
    Toshiyuki Saiga
    Toshiaki Ito
    Surgery Today, 2019, 49 : 118 - 123
  • [23] Total endoscopic robotic atrial septal defect repair in a patient with dextrocardia and situs inversus totalis
    Iino, Kenji
    Watanabe, Go
    Ishikawa, Norihiko
    Tomita, Shigeyuki
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (04) : 476 - 477
  • [24] Intermediate-Term Outcomes of Totally Endoscopic Atrial Septal Defect Repair on Beating Heart in Small Children
    Nguyen, Uoc H.
    Dang, Huy Q.
    Nguyen, Huu C.
    Le, Thanh N.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2022, 17 (03) : 223 - 230
  • [25] Totally endoscopic atrial septal defect repair using transthoracic aortic cannulation in a 10.5-kg-boy
    Dang, Huy Q.
    Le, Huong T.
    Ngo, Linh T. H.
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2018, 52 : 103 - 106
  • [26] Totally Endoscopic Resection of Giant Left Atrial Myxoma Without Robotic Assistance
    Quang-Huy Dang
    Ngoc-Thanh Le
    Dac-Dai Tran
    Thi-Hai-Linh Ngo
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2018, 13 (02) : 136 - 139
  • [27] Transcatheter closure vs totally endoscopic robotic surgery for atrial septal defect closure: A single-center experience
    Kadirogullari, Ersin
    Onan, Burak
    Timur, Baris
    Birant, Ali
    Reyhancan, Adem
    Basgoze, Serdar
    Aydin, Unal
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (04) : 764 - 771
  • [28] Totally endoscopic mitral valve repair without robotic assistance: A case report
    Pham, Dat T.
    Nguyen, Huu C.
    Le, Thanh N.
    Doan, Hung Q.
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2020, 75 : 162 - 165
  • [29] Totally endoscopic atrial septal repair in adults with computer-enhanced telemanipulation
    Wimmer-Greinecker, G
    Dogan, S
    Aybek, T
    Khan, MF
    Mierdl, S
    Byhahn, C
    Moritz, A
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (02) : 465 - 468
  • [30] Totally endoscopic atrial septal defect repair in a patient with interrupted inferior vena cava with azygos-hemiazygos continuation
    Dang, Huy Q.
    Tran, Manh T.
    Nguyen, Ngoc M.
    Le, Huong T.
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (12) : 4814 - 4817