摘要
The measurement of human motion is an important aspect of ergonomic mobility design, in which the mobility product is evaluated based on human factors obtained by digital human (DH) technologies. The optical motion-capture (MoCap) system has been widely used for measuring human motion in laboratories. However, it is generally difficult to measure human motion using mobility products in real-world scenarios, e.g., riding a bicycle on an outdoor slope, owing to unstable lighting conditions and camera arrangements. On the other hand, the inertial-measurement-unit (IMU)-based MoCap system does not require any optical devices, providing the potential for measuring riding motion even in outdoor environments. However, in general, the estimated motion is not necessarily accurate as there are many errors due to the nature of the IMU itself, such as drift and calibration errors. Thus, it is infeasible to apply the IMU-based system to riding motion estimation. In this study, we develop a new riding MoCap system using IMUs. The proposed system estimates product and human riding motions by combining the IMU orientation with contact constraints between the product and DH, e.g., DH hands in contact with handles. The proposed system is demonstrated with a bicycle ergometer, including the handles, seat, backrest, and foot pedals, as in general mobility products. The proposed system is further validated by comparing the estimated joint angles and positions with those of the optical MoCap for three different subjects. The experiment reveals both the effectiveness and limitations of the proposed system. It is confirmed that the proposed system improves the joint position estimation accuracy compared with a system using only IMUs. The angle estimation accuracy is also improved for near joints. However, it is observed that the angle accuracy decreases for a few joints. This is explained by the fact that the proposed system modifies the orientations of all body segments to satisfy the contact constraints, even if the orientations of a few joints are correct. This further confirms that the elapsed time using the proposed system is sufficient for real-time application.
引用
收藏
页码:506 / 516
页数:11
相关论文
共 50 条
  • [41] A lightweight and scalable visual-inertial motion capture system using fiducial markers
    Guoping He
    Shangkun Zhong
    Jifeng Guo
    Autonomous Robots, 2019, 43 : 1895 - 1915
  • [42] A lightweight and scalable visual-inertial motion capture system using fiducial markers
    He, Guoping
    Zhong, Shangkun
    Guo, Jifeng
    AUTONOMOUS ROBOTS, 2019, 43 (07) : 1895 - 1915
  • [43] Feasibility of Bluetooth Low Energy for motion capturing with Inertial Measurement Units
    Veijalainen, Pyry
    Charalambous, Themistoklis
    Wichman, Risto
    JOURNAL OF NETWORK AND COMPUTER APPLICATIONS, 2023, 213
  • [44] Low Cost Inertial Measurement Unit for Motion Capture in Biomedical Applications
    Lourenco, Joao
    Martins, Leonardo
    Almeida, Rui
    Quaresma, Claudia
    Vieira, Pedro
    TECHNOLOGICAL INNOVATION FOR CYBER-PHYSICAL SYSTEMS, 2016, 470 : 151 - 158
  • [45] Dynamic accuracy of inertial measurement units during simple pendulum motion
    Brodie, M. A.
    Walmsley, A.
    Page, W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 (03) : 235 - 242
  • [46] Validity of inertial measurement units for tracking human motion: a systematic review
    Ghattas, John
    Jarvis, Danielle N.
    SPORTS BIOMECHANICS, 2021,
  • [47] A Low-Cost Inertial Measurement Unit Motion Capture System for Operation Posture Collection and Recognition
    Yin, Mingyue
    Li, Jianguang
    Wang, Tiancong
    SENSORS, 2024, 24 (02)
  • [48] Quaternion-Based Local Frame Alignment between an Inertial Measurement Unit and a Motion Capture System
    Lee, Jung Keun
    Jung, Woo Chang
    SENSORS, 2018, 18 (11)
  • [49] Concurrent Validity Of Inertial Measurement Units With 3D Motion Analysis System For Joint Kinematics
    Balardi, Kathryn
    Johnson, Michael
    Ross, Jaclyn
    Chinworth, Susan
    Vallabhajosula, Srikant
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 130 - 131
  • [50] Software Environment for Motion Capture System Based on Inertial Sensors
    Ivanov, Artem V.
    Zhilenkova, Elena A.
    PROCEEDINGS OF THE 2019 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2019, : 230 - 234