Riding Motion Capture System Using Inertial Measurement Units with Contact Constraints

被引:10
作者
Maruyama, Tsubasa [1 ]
Tada, Mitsunori [2 ]
Toda, Haruki [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Human Augmentat Res Ctr, 6-2-3 Kashiwanoha, Kashiwa, Chiba 2770882, Japan
[2] Natl Inst Adv Ind Sci & Technol, Artificial Intelligence Res Ctr, Tokyo, Japan
关键词
ergonomic design; motion capture; inertial measurement unit; digital human; human-machine interaction; ACCURACY; DESIGN;
D O I
10.20965/ijat.2019.p0506
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The measurement of human motion is an important aspect of ergonomic mobility design, in which the mobility product is evaluated based on human factors obtained by digital human (DH) technologies. The optical motion-capture (MoCap) system has been widely used for measuring human motion in laboratories. However, it is generally difficult to measure human motion using mobility products in real-world scenarios, e.g., riding a bicycle on an outdoor slope, owing to unstable lighting conditions and camera arrangements. On the other hand, the inertial-measurement-unit (IMU)-based MoCap system does not require any optical devices, providing the potential for measuring riding motion even in outdoor environments. However, in general, the estimated motion is not necessarily accurate as there are many errors due to the nature of the IMU itself, such as drift and calibration errors. Thus, it is infeasible to apply the IMU-based system to riding motion estimation. In this study, we develop a new riding MoCap system using IMUs. The proposed system estimates product and human riding motions by combining the IMU orientation with contact constraints between the product and DH, e.g., DH hands in contact with handles. The proposed system is demonstrated with a bicycle ergometer, including the handles, seat, backrest, and foot pedals, as in general mobility products. The proposed system is further validated by comparing the estimated joint angles and positions with those of the optical MoCap for three different subjects. The experiment reveals both the effectiveness and limitations of the proposed system. It is confirmed that the proposed system improves the joint position estimation accuracy compared with a system using only IMUs. The angle estimation accuracy is also improved for near joints. However, it is observed that the angle accuracy decreases for a few joints. This is explained by the fact that the proposed system modifies the orientations of all body segments to satisfy the contact constraints, even if the orientations of a few joints are correct. This further confirms that the elapsed time using the proposed system is sufficient for real-time application.
引用
收藏
页码:506 / 516
页数:11
相关论文
共 30 条
  • [1] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    [J]. SENSORS, 2018, 18 (03):
  • [2] [Anonymous], 2009, Biomechanics and motor control of human movement
  • [3] [Anonymous], HUMAN FACTORS ERGONO
  • [4] Realtime Multi-Person 2D Pose Estimation using Part Affinity Fields
    Cao, Zhe
    Simon, Tomas
    Wei, Shih-En
    Sheikh, Yaser
    [J]. 30TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2017), 2017, : 1302 - 1310
  • [5] Comparison of Markerless and Marker-Based Motion Capture Technologies through Simultaneous Data Collection during Gait: Proof of Concept
    Ceseracciu, Elena
    Sawacha, Zimi
    Cobelli, Claudio
    [J]. PLOS ONE, 2014, 9 (03):
  • [6] Magnetic distortion in motion labs, implications for validating inertial magnetic sensors
    de Vries, W. H. K.
    Veeger, H. E. J.
    Baten, C. T. M.
    van der Helm, F. C. T.
    [J]. GAIT & POSTURE, 2009, 29 (04) : 535 - 541
  • [7] QUASI-NEWTON METHODS, MOTIVATION AND THEORY
    DENNIS, JE
    MORE, JJ
    [J]. SIAM REVIEW, 1977, 19 (01) : 46 - 89
  • [8] Endo Y., 2014, P DIG HUM MOD 2014
  • [9] Hand modeling and motion reconstruction for individuals
    Endo, Yui
    Tada, Mitsunori
    Mochimaru, Masaaki
    [J]. International Journal of Automation Technology, 2014, 8 (03) : 376 - 387
  • [10] Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
    Filippeschi, Alessandro
    Schmitz, Norbert
    Miezal, Markus
    Bleser, Gabriele
    Ruffaldi, Emanuele
    Stricker, Didier
    [J]. SENSORS, 2017, 17 (06)