High-frequency oscillatory ventilation with volume guarantee: a single-centre experience

被引:24
作者
Belteki, Gusztav [1 ]
Morley, Colin J. [1 ]
机构
[1] Cambridge Univ Hosp NHS Trust, Rosie Hosp, Neonatal Intens Care Unit, Cambridge, England
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2019年 / 104卷 / 04期
关键词
Hfov; Mechanical Ventilation; Neonatology; Volume-targeted Ventilation; PRETERM INFANTS; TIDAL VOLUME; LUNG INJURY; REMOVAL;
D O I
10.1136/archdischild-2018-315490
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective High-frequency oscillatory ventilation (HFOV) is widely used in neonatology. The Drager Babylog VN500 ventilator offers volume-guaranteed HFOV (HFOV-VG) mode when the high-frequency tidal volume (VThf) to be delivered can be set. We investigated how HFOV-VG maintains VThf in the short and longer term and how it affects other ventilator parameters and blood gases. Methods We downloaded similar to 3.2 million seconds (36.7 days) of ventilator data from 17 infants ventilated using HFOV-VG during clinical care with 1 Hz sampling rate. To process and analyse the data, we used the Python computer language. Results Overall, the median VThf was 1.93 mL/kg (IQR 1.64-2.45 mL/kg). The difference between set and delivered tidal volume was <0.2 mL/kg for 83% of time. In the individual recordings, the median VThf ranged between 1.44 and 3.31 mL/kg. During HFOV-VG, the VThf varied from 1 second to another, but it was very close to the target value when averaged over 5 min periods. After weight correction, the VThf or the diffusion coefficient of carbon dioxide (DCO2) showed weak inverse correlation with partial pressure of CO2(pCO(2)) (for VThf, r=-0.162, 95% CI -0.282 to -0.037, p=0.01). Uncorrected values showed no correlation. Of the 53 blood gas measurements taken when VThf was >2.5 mL/kg, there were only six (11%) with a pCO(2) >8 kPa. Conclusions During HFOV-VG, the tidal volume of oscillations varies in the short term but is maintained very close to the target over the longer term. VThf or DCO2 have poor correlation with CO2 levels but a volume of >2.5 mL/kg VThf is rarely needed.
引用
收藏
页码:F384 / F389
页数:6
相关论文
共 22 条
  • [1] Patient-ventilator interactions in new modes of patient-triggered ventilation
    Abubakar, KM
    Keszler, M
    [J]. PEDIATRIC PULMONOLOGY, 2001, 32 (01) : 71 - 75
  • [2] Belteki G, 2018, ARCH DIS CHILD-FETAL, V103, pF307, DOI 10.1136/archdischild-2017-313493
  • [3] Weight-correction of carbon dioxide diffusion coefficient (DCO2) reduces its inter-individual variability and improves its correlation with blood carbon dioxide levels in neonates receiving high-frequency oscillatory ventilation
    Belteki, Gusztav
    Lin, Benjamin
    Morley, Colin J.
    [J]. PEDIATRIC PULMONOLOGY, 2017, 52 (10) : 1316 - 1322
  • [4] Transcutaneous carbon dioxide monitoring during high-frequency oscillatory ventilation in infants and children
    Berkenbosch, JW
    Tobias, JD
    [J]. CRITICAL CARE MEDICINE, 2002, 30 (05) : 1024 - 1027
  • [5] GAS-EXCHANGE IN HEALTHY RABBITS DURING HIGH-FREQUENCY OSCILLATORY VENTILATION
    BOYNTON, BR
    HAMMOND, MD
    FREDBERG, JJ
    BUCKLEY, BG
    VILLANUEVA, D
    FRANTZ, ID
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (03) : 1343 - 1351
  • [6] Elective high frequency oscillatory ventilation versus conventional ventilation for acute pulmonary dysfunction in preterm infants
    Cools, Filip
    Offringa, Martin
    Askie, Lisa M.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (03):
  • [7] Effect of Volume Guarantee in Preterm Infants on High-Frequency Oscillatory Ventilation: A Pilot Study
    Enomoto, Masahiro
    Keszler, Martin
    Sakuma, Mio
    Kikuchi, Shin
    Katayama, Yoshinori
    Takei, Atsuko
    Ikegami, Hitoshi
    Minami, Hirotaka
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (01) : 26 - 30
  • [8] Using very high frequencies with very low lung volumes during high-frequency oscillatory ventilation to protect the immature lung. A pilot study
    Gonzalez-Pacheco, N.
    Sanchez-Luna, M.
    Ramos-Navarro, C.
    Navarro-Patino, N.
    de la Blanca, A. R-S
    [J]. JOURNAL OF PERINATOLOGY, 2016, 36 (04) : 306 - 310
  • [9] CHEST WALL RESTRICTION LIMITS HIGH AIRWAY PRESSURE-INDUCED LUNG INJURY IN YOUNG-RABBITS
    HERNANDEZ, LA
    PEEVY, KJ
    MOISE, AA
    PARKER, JC
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (05) : 2364 - 2368
  • [10] Brief, large tidal volume ventilation initiates lung injury and a systemic response in fetal sheep
    Hillman, Noah H.
    Moss, Timothy J. M.
    Kallapur, Suhas G.
    Bachurski, Cindy
    Pillow, J. Jane
    Polglase, Graeme R.
    Nitsos, Ilias
    Kramer, Boris W.
    Jobe, Alan H.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2007, 176 (06) : 575 - 581