Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation

被引:44
|
作者
Ding, Xiaorong [1 ]
Zhang, Yuanting [1 ]
Tsang, Hon Ki [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
heart disease; calibration interval; pulse transit time; blood pressure; estimation accuracy; FINGER PHOTOPLETHYSMOGRAM; ARRIVAL-TIME; VALIDATION; HYPERTENSION; DEVICES;
D O I
10.1088/0967-3334/37/2/227
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [31] An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects
    Wong, Mico Yee-Man
    Poon, Carmen Chung-Yan
    Zhang, Yuan-Ting
    CARDIOVASCULAR ENGINEERING, 2009, 9 (01) : 32 - 38
  • [32] A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study
    Shin, Hangsik
    PSYCHOPHYSIOLOGY, 2023, 60 (02)
  • [33] A Camera-Based Pulse Transit Time Estimation Approach Towards Non-Intrusive Blood Pressure Monitoring
    Patil, Omkar R.
    Wang, Wei
    Gao, Yang
    Jin, Zhanpeng
    2019 IEEE INTERNATIONAL CONFERENCE ON HEALTHCARE INFORMATICS (ICHI), 2019, : 257 - 266
  • [34] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315
  • [35] Effects of continuous positive airway pressure on very short-term blood pressure variability associated with sleep-disordered breathing by pulse transit time-based blood pressure measurements
    Misaka, Tomofumi
    Yoshihisa, Akiomi
    Yokokawa, Tetsuro
    Takeishi, Yasuchika
    JOURNAL OF HYPERTENSION, 2023, 41 (05) : 733 - 740
  • [36] Evaluation of the Correlation Between Blood Pressure and Pulse Transit Time
    He, Xiaochuan
    Goubran, Rafik A.
    Liu, Xiaoping P.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 17 - 20
  • [37] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [38] Restrictive factors of the measurement accuracy to estimate Blood Pressure with Pulse wave Transit Time
    Chen, X. M.
    Li, Y. B.
    Zhang, Y.
    Deng, N.
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING: NEW ADVANCES, 2016, : 435 - 441
  • [39] Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
    Polinski, Artur
    Bujnowski, Adam
    Kocejko, Tomasz
    Wtorek, Jerzy
    2020 13TH INTERNATIONAL CONFERENCE ON HUMAN SYSTEM INTERACTION (HSI), 2020, : 289 - 294
  • [40] Correlation Study Between Blood Pressure And Pulse Transit Time
    Pereira, T.
    Sanches, R.
    Reis, P.
    Pego, J.
    Simoes, R.
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,